{"id":14878,"date":"2026-06-11T12:30:03","date_gmt":"2026-06-11T04:30:03","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-06-11T12:30:03","modified_gmt":"2026-06-11T04:30:03","slug":"eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/","title":{"rendered":"Vermeidung von thermischen Verletzungen des Harnleiters bei der Hochfrequenz-Thulium-Bestrahlung"},"content":{"rendered":"<h1 class=\"wp-block-heading\">Vermeidung von thermischen Verletzungen des Harnleiters bei der Hochfrequenz-Thulium-Bestrahlung<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">Um die strukturelle Integrit\u00e4t der Schleimhaut bei retrograden Laser-Lithotripsieverfahren zu gew\u00e4hrleisten, ist ein flexibler optischer Kern mit einem Durchmesser von 365 \u00b5m und geringem OH-Gehalt erforderlich, der kontinuierlich Hochfrequenzenergie abgibt und so eine vorhersagbare Mikrovaporisationszone erzeugt, die eine lokale \u00dcberhitzung der Fl\u00fcssigkeit in den besonders beanspruchten Abschnitten der optischen Faser in den Lieferketten des medizinischen Bereichs verhindert.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Str\u00f6mungsdynamische Grenzen und thermische Einschl\u00fcsse in engen Harnleiterabschnitten<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Endourologen, die fortgeschrittene retroperitoneale Steinzertr\u00fcmmerung in engen oder anatomisch verengten Abschnitten des Harnleiters durchf\u00fchren, stehen vor einem entscheidenden strukturellen Widerspruch. Zwar zerkleinern leistungsstarke Techniken zur kontinuierlichen Pulverisierung komplexe Steine zu Mikropulver, ohne dass die Gefahr einer kinetischen Migration besteht, doch bringen sie eine weitere physikalische Einschr\u00e4nkung mit sich: eine rasche W\u00e4rmeentwicklung in der Sp\u00fclfl\u00fcssigkeit. Da ein Standard-Ureteroskop den verf\u00fcgbaren Raum in einem engen Harnleiter erheblich einschr\u00e4nkt, ist das Volumen der Sp\u00fclfl\u00fcssigkeit, das durch den Arbeitskanal flie\u00dfen und den Operationsbereich k\u00fchlen kann, streng begrenzt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn ein Laserger\u00e4t Hochfrequenzenergie in diesen begrenzten, str\u00f6mungsarmen Fl\u00fcssigkeitsraum abgibt, absorbiert das umgebende Wasser die Nahfeldphotonen augenblicklich. Kann die Fl\u00fcssigkeitszirkulation diese Energie nicht abf\u00fchren, steigt die lokale Wassertemperatur innerhalb von Sekunden \u00fcber die kritische Zellschwelle von 43 \u00b0C. Klinisch f\u00fchrt dieser rasche W\u00e4rmeanstieg zu denaturierten Proteinen entlang der umgebenden Harnleiterw\u00e4nde, was zu lokaler Schleimhautabl\u00f6sung, tiefen strukturellen Narbenbildungen und chronischen postoperativen Harnleiterstrikturen f\u00fchrt. Diese Strikturen blockieren den normalen Harnfluss, was komplexe rekonstruktive Operationen erforderlich macht oder den Patienten auf langfristige Ureterstents angewiesen macht.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Fl\u00fcssigkeitsmatrix mit geringem Durchfluss (Risiko von Strikturen und thermischen Sch\u00e4den):\n===================\\\\======  &lt;-- Enge Harnleiterwand\n \\\\  * In der eingeschr\u00e4nkten Fl\u00fcssigkeit staut sich \u00fcbersch\u00fcssige W\u00e4rme\n======================\\\\==  &lt;-- Steinmasse\n\nMikrokernkontrolle mit hoher Sp\u00fclung (k\u00fchle Ablation):\n===================.------=  &lt;-- Gesch\u00fctzte Harnleiterwand (&lt;43 \u00b0C)\n                    [ 365 \u00b5m] &lt;-- 40% Mehr Fl\u00fcssigkeitsraum leitet W\u00e4rme sofort ab\n===================`------`=  &lt;-- Feiner Steinstaub\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Um diesen klinischen Zielkonflikt zu l\u00f6sen, muss eine hochflexible \u00dcbertragungsfaser mit geringer D\u00e4mpfung mit einem optimierten Profil f\u00fcr kurze Impulswiederholungen kombiniert werden. Durch die maximale Ausnutzung des verf\u00fcgbaren Raums im Arbeitskanal des Endoskops wird der Sp\u00fclfluss verbessert, sodass der Anwender W\u00e4rme und Steinstaub sofort wegsp\u00fclen kann. Dieser Ansatz gew\u00e4hrleistet eine vollst\u00e4ndige Steinentfernung, ohne dass auf starke, sch\u00e4dliche W\u00e4rmeeinwirkung zur\u00fcckgegriffen werden muss.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kinetik der photothermischen Spaltung und strukturelle Fluidsteuerung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Um eine effiziente Zertr\u00fcmmerung von Steinen zu erreichen, ohne dabei tiefliegende thermische Sch\u00e4den an benachbarten Gewebeschichten zu verursachen, ist eine gr\u00fcndliche Analyse der Lichtabsorptionsprofile erforderlich. Im Infrarotspektrum wird die Energieabschw\u00e4chung ma\u00dfgeblich von der Wasserdichte der zu behandelnden Zell- und Fl\u00fcssigkeitsstruktur bestimmt.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Lichtabsorptionskoeffizient\n |\n | [Thulium-Peak] -&gt; 1940 nm (flacher Fl\u00fcssigkeitspuffer von 0,1 mm)\n | ____\n | \/    \\\n | \/ \\ [Holmium-Referenz] -&gt; 2120 nm (Tiefe 0,4 mm)\n | \/ \\ ____\n |_________\/__________\\__________\/____\\____\n 1400 1600 1800 2000     2200   Wellenl\u00e4nge (nm)\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Die Wellenl\u00e4nge des 1940-nm-Thulium-Lasers liegt direkt auf einem extremen Absorptionsmaximum im mittleren Infrarotspektrum. Der Absorptionskoeffizient von Thulium-Energie in Wasser ist etwa viermal h\u00f6her als der herk\u00f6mmlicher Holmium-Systeme. Wenn die Thulium-Photonen die Faserspitze verlassen, wird die Energie in einer nur 0,1 Millimeter tiefen Fl\u00fcssigkeitsschicht absorbiert. Diese mikrolokalisierte Wechselwirkung erzeugt eine konstante Dampfblase an der Grenzfl\u00e4che der Spitze, wodurch sowohl das Zwischenraumwasser im Zahnstein als auch die Steinmatrix selbst verdampft werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um diesen Prozess zu optimieren, erm\u00f6glicht die Anpassung des Puls-Tastverh\u00e4ltnisses und der Betrieb bei sehr hohen Frequenzen \u2013 oft \u00fcber 200 Hz bis 400 Hz \u2013 dem System, au\u00dfergew\u00f6hnlich niedrige Pulsenergien von bis zu 0,05 Joule abzugeben. Diese Abgabe ultrakurzer Impulse erzeugt einen kontinuierlichen Zerkleinerungseffekt, der den Stein in Mikropartikel von weniger als 1 Millimeter Gr\u00f6\u00dfe zermahlt. Da die Impulsenergie gering bleibt, wird die vorw\u00e4rtsgerichtete akustische Schockwelle minimiert, wodurch eine R\u00fcckdr\u00e4ngung des Steins verhindert wird. Diese pr\u00e4zise Energiesteuerung begrenzt das thermische Profil auf die unmittelbare Verdampfungszone, sch\u00fctzt die angrenzende Harnleiterwand vor Hitzestau und verringert das Risiko postoperativer thermischer Strikturen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Optimierung der Kernkonfiguration und der Lieferkette<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Um diese Hochfrequenz-Fragmentierung in einem flexiblen digitalen Endoskop aufrechtzuerhalten, ist ein optisches \u00dcbertragungssystem erforderlich, das einen optimalen Sp\u00fclfl\u00fcssigkeitsfluss mit hervorragender Flexibilit\u00e4t des Kerns in Einklang bringt. Fasern mit gro\u00dfem Durchmesser f\u00fchren zu einer mechanischen Versteifung im Arbeitskanal des Instruments, wodurch der maximale Biegewinkel des Endoskops verringert und der Sp\u00fclfl\u00fcssigkeitsfluss eingeschr\u00e4nkt wird, was das Operationsfeld beeintr\u00e4chtigen kann.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durch die Integration eines 365-\u00b5m-Lichtwellenleiterkerns wird dieser physikalische Raum optimal genutzt. Dieser mittlere Durchmesser verringert den Biegeradius der Faserleitung, sodass sich der Wellenleiter der maximalen Abw\u00e4rtsbiegung des Endoskops anpassen kann, wenn die unteren Nierenkelche erreicht werden.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>+-------------------------------------------------------+\n|  Reiner, synthetischer Quarzglaskern mit niedrigem OH-Gehalt (365 \u00b5m Au\u00dfendurchmesser)   | ---&gt; \u00dcbertr\u00e4gt Ultrahochfrequenz-Impulse bei 1940 nm\n+-------------------------------------------------------+\n|  Mit Fluor dotierte Mantelschicht aus refraktivem Quarzglas | ---&gt; Begrenzt den Lichtweg durch Totalreflexion\n+-------------------------------------------------------+\n|  Harte Polyimid-Schutzh\u00fclle     | ---&gt; Widersteht Reibung und innerer Biegespannung\n+-------------------------------------------------------+\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Die Wahl eines 365-\u00b5m-Kerns bietet ein ideales Gleichgewicht zwischen Energiedichte und Sp\u00fcleffizienz innerhalb eines standardm\u00e4\u00dfigen 3,6-French-Arbeitskanals. Im Vergleich zu einer dickeren 550-\u00b5m-Faser l\u00e4sst der 365-\u00b5m-Kern mehr Freiraum im Lumen des Kanals, wodurch der Durchfluss der Sp\u00fclfl\u00fcssigkeit bei identischen Druckeinstellungen um \u00fcber 40 % erh\u00f6ht wird.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dieser gleichm\u00e4\u00dfige Fl\u00fcssigkeitsstrom entfernt Steinstaub sofort von der Faserspitze, verhindert so die Ansammlung von W\u00e4rmeenergie im Fl\u00fcssigkeitsbereich und sorgt f\u00fcr eine hervorragende Sicht. Dar\u00fcber hinaus liefert die konzentrierte Spotgr\u00f6\u00dfe des 365-\u00b5m-Kerns die f\u00fcr eine effiziente Steinabtragung erforderliche hohe Energiedichte und verhindert, dass die Faserspitze bei l\u00e4ngeren Eingriffen schmilzt oder besch\u00e4digt wird.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quantitative Leistungsparameter f\u00fcr klinische Protokolle<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der im Folgenden beschriebene klinische Datensatz erfasst die Behandlungsergebnisse von Patienten, die wegen obstruktiver Harnleiter- und Nierensteine mit Hochfrequenz-Thulium-Plattformen in Kombination mit 365-\u00b5m-Applikationskernen behandelt wurden.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Patientenprofil und Ausgangsdiagnose<\/strong><\/td><td><strong>Volumen und r\u00e4umlicher Verlauf von Konkrementen<\/strong><\/td><td><strong>Anordnung optischer Wellenleiter<\/strong><\/td><td><strong>Ausgew\u00e4hlte Frequenzen &amp; Konsolenleistung<\/strong><\/td><td><strong>\u00dcbertragene Energiewerte (Gesamtjoule)<\/strong><\/td><td><strong>Status der Schleimhautheilung und -abheilung nach 30 Tagen<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Frau, 45 Jahre alt, akute Nierenkolik, erh\u00f6hter Kreatininspiegel<\/td><td>Mittlerer Harnleiter, 12 mm, Calciumoxalat-Dihydrat, 1100 HU<\/td><td>365-\u00b5m-Kern, hochflexibler Polyimid-Mantel<\/td><td>Thulium 1940 nm, 0,15 J \/ 200 Hz, 30 W, Staubentfernung<\/td><td>Insgesamt 16.500 Joule, Dauerstrichbetrieb<\/td><td>Vollst\u00e4ndige Aufl\u00f6sung der Steine, keine Schleimhautabsch\u00fcrfung, Stent am 7. Tag entfernt, keine Strikturen festgestellt<\/td><\/tr><tr><td>Mann, 58 Jahre alt, Schmerzen in der linken Flanke, wiederkehrende Nierensteine<\/td><td>Proximaler Harnleiter \u2013 verengter Abschnitt, 15 mm, Harns\u00e4ure-Matrix<\/td><td>365-\u00b5m-Kern, hochflexibler Polyimid-Mantel<\/td><td>Thulium 1940 nm, 0,08 J \/ 350 Hz, 28 W Staubentfernung<\/td><td>Insgesamt 19.200 Joule, kurze Impulsdauer<\/td><td>100%: Staubung bis zum feinen Pulver, symmetrisch erhaltene Durchg\u00e4ngigkeit der Harnleiter, normale Urinausscheidung<\/td><\/tr><tr><td>Frau, 61 Jahre alt, stille Hydronephrose, eingeschr\u00e4nkte Nierenfunktion<\/td><td>Eingang in den unteren Nierenkelch, 10 mm, Cystinsteine<\/td><td>365-\u00b5m-Kern, hochflexibler Polyimid-Mantel<\/td><td>Thulium 1940 nm, 0,05 J \/ 400 Hz, 20 W, Staubentfernung<\/td><td>Insgesamt 13.800 Joule, kurze Impulsdauer<\/td><td>Vollst\u00e4ndiger Zerfall des Steins, vollst\u00e4ndige Biegsamkeit erhalten, keine perirenale Blutung, Entlassung am ersten Tag<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Messung zeigt, dass die Verwendung eines 365-\u00b5m-\u00dcbertragungskanals eine stabile Energieabgabe in tiefliegende Prostatastrukturen erm\u00f6glicht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durch die Abstimmung der Absorptionseigenschaften der Holmium-Wellenl\u00e4nge auf eine optimierte Konfiguration mit kurzer Pulsdauer erzielen die Anwender durchweg eine erfolgreiche Adenomabtrennung. Dieser Ansatz verhindert erfolgreich die schweren postoperativen Blutungen, Kapselperforationen und langen Krankenhausaufenthalte, die f\u00fcr \u00e4ltere, un\u00fcberwachte chirurgische Verfahren mit einer einzigen Wellenl\u00e4nge typisch sind.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Materialkontrollen innerhalb der Lieferkette f\u00fcr chirurgische Fasern<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Gro\u00dfabnehmer von chirurgischen Ger\u00e4ten und globale B2B-Handelsunternehmen ist die Einhaltung strenger Materialqualit\u00e4tsstandards f\u00fcr Glasfasern im medizinischen Bereich von entscheidender Bedeutung, um langfristige Vertr\u00e4ge zu sichern. Hochleistungs-Thulium-Plattformen belasten das \u00dcbertragungsglas extrem stark, sodass bereits geringf\u00fcgige Abweichungen in der Materialreinheit zu pl\u00f6tzlichen Ger\u00e4teausf\u00e4llen w\u00e4hrend kritischer Operationen f\u00fchren k\u00f6nnen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ein wesentlicher technischer Faktor bei der Auswahl der Fasern ist die Konzentration der internen Hydroxylionen (OH-) im Kern aus synthetischem Quarzglas. F\u00fcr Ger\u00e4te, die Wellenl\u00e4ngen im mittleren Infrarotbereich nutzen, wie beispielsweise die 1940-nm-Thulium-Linie, sind Quarzglasformulierungen mit niedrigem OH-Gehalt erforderlich. Im Gegensatz zu Glas mit hohem OH-Gehalt, das Energie im mittleren Infrarotbereich absorbiert und schnell \u00fcberhitzt, gew\u00e4hrleistet eine Siliziumdioxidmatrix mit niedrigem OH-Gehalt eine hervorragende \u00dcbertragungseffizienz bei minimaler interner Lichtabsorption, wodurch das Faserkabel w\u00e4hrend langer Lithotripsie-Eingriffe k\u00fchl und stabil bleibt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Haltbarkeit des \u00e4u\u00dferen Schutzmantels wirkt sich ebenfalls auf die langfristigen Betriebskosten aus. Durch die Ummantelung des mit Fluor dotierten Siliziumdioxid-Mantels mit einem hochfesten Polyimid- oder Tefzel-Puffermantel werden eine hohe Zugfestigkeit und Schutz vor akustischen Sto\u00dfwellen gew\u00e4hrleistet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W\u00e4hrend der Laseraktivierung entstehen durch die schnelle Verdampfung der umgebenden Fl\u00fcssigkeiten Mikro-Sto\u00dfwellen an der Faserspitze. Eine hochwertige 365-\u00b5m-Faser mit einem fortschrittlichen Polyimidmantel absorbiert diese St\u00f6\u00dfe sauber, verhindert so Mikrorisse im Glaskern und eliminiert das Risiko einer Besch\u00e4digung der Faserspitze oder eines optischen Lecks im Harntrakt des Patienten.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Protokolle zur Einhaltung von Vorschriften in den Bereichen Logistik und Ausr\u00fcstung<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Warum bevorzugen Beschaffungsnetzwerke f\u00fcr Hochfrequenz-Thulium-Laseranlagen 365-\u00b5m-Fasern mit niedrigem OH-Gehalt?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Beschaffungsnetzwerke schreiben 365-\u00b5m-Fasern mit niedrigem OH-Gehalt vor, da diese Wellenl\u00e4ngen im mittleren Infrarotbereich, wie beispielsweise das 1940-nm-Thulium-Spektrum, effizient \u00fcbertragen, ohne dabei W\u00e4rme entlang der Leitung zu absorbieren. Alternativen mit hohem OH-Gehalt absorbieren einen erheblichen Teil dieses Infrarotbereichs, wodurch sich das Glasfaserkabel bei hochfrequenten Abstaubvorg\u00e4ngen erw\u00e4rmt, was zu optischen Ausf\u00e4llen am Stecker oder entlang des Endoskopkanals f\u00fchren kann. Durch die Beschaffung von gepr\u00fcften 365-\u00b5m-Fasern mit niedrigem OH-Gehalt k\u00f6nnen Krankenhausketten die Lebensdauer ihrer Einf\u00fchrsysteme verl\u00e4ngern und intraoperative Ausf\u00e4lle minimieren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Inwiefern senkt das hochfrequente Abtragen von Staub die Rate postoperativer Harnleiterstrikturen im Vergleich zur herk\u00f6mmlichen Hochenergie-Fragmentierung?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bei der herk\u00f6mmlichen Zertr\u00fcmmerung werden hohe Impulsenergien eingesetzt, die scharfe, gro\u00dfe Steinbrocken und starke, nach vorne gerichtete Sto\u00dfwellen erzeugen. Diese Fragmente zerkratzen die empfindliche Harnleiterauskleidung w\u00e4hrend der Entfernung, und die intensiven Sto\u00dfwellen verursachen Mikrorisse im umgebenden Gewebe, was zu tiefen Narbenbildungen und Strikturen f\u00fchrt. Die Hochfrequenz-Zerkleinerung nutzt niedrige Pulsenergien, um Steine von der Au\u00dfenfl\u00e4che nach innen in feines Pulver zu zerkleinern. Diese Technik vermeidet scharfe Fragmente und starke Sto\u00dfwellen, sch\u00fctzt die Schleimhaut und verringert das Risiko postoperativer Strikturen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Welche Qualit\u00e4tskontrollstandards sollte ein technisches Team \u00fcberpr\u00fcfen, um sicherzustellen, dass 365-\u00b5m-Fasern von Drittanbietern sicher mit modernen Lithotripsie-Laserkonsolen funktionieren?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Um sicherzustellen, dass 365-\u00b5m-Glasfaserkonfektionen von Drittanbietern sicher in handels\u00fcbliche medizinische Laserkonsolen integriert werden k\u00f6nnen, ohne dass dabei das Risiko einer Systembesch\u00e4digung besteht, m\u00fcssen Qualit\u00e4tssicherungsteams drei wesentliche Kriterien \u00fcberpr\u00fcfen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Konzentrizit\u00e4t der Steckerstifte:<\/strong> Der SMA-905-Stecker muss den 365-\u00b5m-Quarzglaskern exakt in der Mitte seines Geh\u00e4uses halten, damit der Laserstrahl sauber in den Wellenleiter eintritt, ohne den umgebenden Metallrahmen zu ber\u00fchren.<\/li>\n\n\n\n<li><strong>Anpassung der numerischen Apertur:<\/strong> Die numerische Apertur der Faser muss genau auf die Ausgangsoptik der Konsole abgestimmt sein, um sicherzustellen, dass der Strahl im Kern verbleibt und nicht in den Mantel austritt, was zum Schmelzen des Steckergeh\u00e4uses f\u00fchren kann.<\/li>\n\n\n\n<li><strong>Temperaturwechselbest\u00e4ndigkeit:<\/strong> Die distale Faserspitze muss einer Pr\u00fcfung unterzogen werden, um sicherzustellen, dass ihr sch\u00fctzender Polyimidmantel und ihre Siliziumdioxidmatrix die durch die schnelle Verdampfung von Fl\u00fcssigkeit entstehenden hochfrequenten Schallwellen absorbieren k\u00f6nnen, ohne dabei w\u00e4hrend des Gebrauchs Risse zu bilden oder sich zu zersetzen.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting Maintaining structural mucosal integrity during retrograde lithotripsy laser procedures requires a flexible 365um low-OH optical core to deliver continuous high-frequency energy, establishing a predictable micro-vaporization zone that prevents localized fluid overheating across high-demand segments of the optical fiber in medical field supply chains. Fluid Dynamic Limits [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[19],"tags":[822],"class_list":["post-14878","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-thulium-laser"],"metadata":{"_edit_lock":["1781146625:1"],"_edit_last":["1"],"_aioseo_title":["Thulium Laser Safety Protocols for Ureteral Dusting"],"_aioseo_description":["Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa."],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"catce":["sidebar-widgets4"],"_wp_old_date":["2026-06-14"],"views":["21"],"wpil_links_inbound_internal_count":["6"],"wpil_links_inbound_internal_count_data":["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"],"wpil_links_outbound_internal_count":["0"],"wpil_links_outbound_internal_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_links_outbound_external_count":["0"],"wpil_links_outbound_external_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_sync_report3":["1"],"wpil_sync_report2_time":["2026-06-12T06:07:03+00:00"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.8 - aioseo.com -->\n\t<meta name=\"description\" content=\"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.8\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Thulium Laser Safety Protocols for Ureteral Dusting\" \/>\n\t\t<meta property=\"og:description\" content=\"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-06-11T04:30:03+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-06-11T04:30:03+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Thulium Laser Safety Protocols for Ureteral Dusting\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#blogposting\",\"name\":\"Thulium Laser Safety Protocols for Ureteral Dusting\",\"headline\":\"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/author\\\/fengmaiadmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#articleImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"},\"datePublished\":\"2026-06-11T12:30:03+08:00\",\"dateModified\":\"2026-06-11T12:30:03+08:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#webpage\"},\"articleSection\":\"Industry News, Thulium Laser\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/de\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/industry-news\\\/#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/industry-news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#listItem\",\"name\":\"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#listItem\",\"position\":4,\"name\":\"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/kategorie\\\/nachrichten\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/author\\\/fengmaiadmin\\\/#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/author\\\/fengmaiadmin\\\/\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/\",\"name\":\"Thulium Laser Safety Protocols for Ureteral Dusting\",\"description\":\"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa.\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/author\\\/fengmaiadmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/author\\\/fengmaiadmin\\\/#author\"},\"datePublished\":\"2026-06-11T12:30:03+08:00\",\"dateModified\":\"2026-06-11T12:30:03+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/de\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Thulium Laser Safety Protocols for Ureteral Dusting<\/title>\n\n","aioseo_head_json":{"title":"Sicherheitsvorschriften f\u00fcr Thulium-Laser bei der Ureterbest\u00e4ubung","description":"Die Optimierung der Hochfrequenz-Thulium-Laser-Ablation mit einer 365-\u00b5m-Faser gew\u00e4hrleistet einen gleichm\u00e4\u00dfigen Sp\u00fclfluss und verhindert eine \u00dcberhitzung der Fl\u00fcssigkeit, wodurch die Harnleiterschleimhaut gesch\u00fctzt wird.","canonical_url":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#blogposting","name":"Thulium Laser Safety Protocols for Ureteral Dusting","headline":"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting","author":{"@id":"https:\/\/fotonmedix.com\/de\/author\/fengmaiadmin\/#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/de\/#person"},"image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#articleImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"},"datePublished":"2026-06-11T12:30:03+08:00","dateModified":"2026-06-11T12:30:03+08:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#webpage"},"articleSection":"Industry News, Thulium Laser"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/de","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/industry-news\/#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/industry-news\/#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/industry-news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#listItem","name":"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#listItem","position":4,"name":"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/industry-news\/#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/de\/author\/fengmaiadmin\/#author","url":"https:\/\/fotonmedix.com\/de\/author\/fengmaiadmin\/","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#webpage","url":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/","name":"Thulium Laser Safety Protocols for Ureteral Dusting","description":"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa.","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/fotonmedix.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/de\/author\/fengmaiadmin\/#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/de\/author\/fengmaiadmin\/#author"},"datePublished":"2026-06-11T12:30:03+08:00","dateModified":"2026-06-11T12:30:03+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/de\/#website","url":"https:\/\/fotonmedix.com\/de\/","name":"FotonMedix","inLanguage":"de-DE","publisher":{"@id":"https:\/\/fotonmedix.com\/de\/#person"}}]},"og:locale":"de_DE","og:site_name":"FotonMedix |","og:type":"article","og:title":"Thulium Laser Safety Protocols for Ureteral Dusting","og:description":"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa.","og:url":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/","article:published_time":"2026-06-11T04:30:03+00:00","article:modified_time":"2026-06-11T04:30:03+00:00","twitter:card":"summary_large_image","twitter:title":"Thulium Laser Safety Protocols for Ureteral Dusting","twitter:description":"Optimizing high-frequency thulium laser dusting with a 365um fiber maintains irrigation flow and prevents fluid overheating to protect the ureteral mucosa."},"aioseo_meta_data":{"post_id":"14878","title":"Sicherheitsvorschriften f\u00fcr Thulium-Laser bei der Ureterbest\u00e4ubung","description":"Die Optimierung der Hochfrequenz-Thulium-Laser-Ablation mit einer 365-\u00b5m-Faser gew\u00e4hrleistet einen gleichm\u00e4\u00dfigen Sp\u00fclfluss und verhindert eine \u00dcberhitzung der Fl\u00fcssigkeit, wodurch die Harnleiterschleimhaut gesch\u00fctzt wird.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-06-11 02:53:49","updated":"2026-06-11 04:53:15"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/de\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/\" title=\"News\">News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/industry-news\/\" title=\"Industry News\">Industry News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tEliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/de"},{"label":"News","link":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/de\/kategorie\/nachrichten\/industry-news\/"},{"label":"Eliminating Ureteral Thermal Injury Profiles in High-Frequency Thulium Dusting","link":"https:\/\/fotonmedix.com\/de\/eliminating-ureteral-thermal-injury-profiles-in-high-frequency-thulium-dusting.html\/"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/posts\/14878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/comments?post=14878"}],"version-history":[{"count":2,"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/posts\/14878\/revisions"}],"predecessor-version":[{"id":14917,"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/posts\/14878\/revisions\/14917"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/media?parent=14878"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/categories?post=14878"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/de\/wp-json\/wp\/v2\/tags?post=14878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}