{"id":12635,"date":"2026-04-14T14:53:00","date_gmt":"2026-04-14T06:53:00","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-04-07T16:33:35","modified_gmt":"2026-04-07T08:33:35","slug":"the-pathophysiology-of-laser-induced-tissue-regeneration-advanced-irradiance-strategies-for-modern-veterinary-clinics","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/es\/the-pathophysiology-of-laser-induced-tissue-regeneration-advanced-irradiance-strategies-for-modern-veterinary-clinics.html\/","title":{"rendered":"Fisiopatolog\u00eda de la regeneraci\u00f3n tisular inducida por l\u00e1ser: Estrategias avanzadas de irradiaci\u00f3n para cl\u00ednicas veterinarias modernas"},"content":{"rendered":"<p>Los sistemas de clase 4 de alta irradiancia optimizan la secci\u00f3n transversal de absorci\u00f3n mitocondrial, garantizando un flujo de fotones tisular profundo a trav\u00e9s de capas d\u00e9rmicas densas para acelerar la s\u00edntesis de ATP, proporcionar una neuromodulaci\u00f3n instant\u00e1nea para la analgesia y lograr una hemostasia fotot\u00e9rmica precisa en entornos quir\u00fargicos complejos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La f\u00edsica de la penetraci\u00f3n: Superar las limitaciones de las modalidades de baja potencia<\/h3>\n\n\n\n<p>En el panorama m\u00e9dico actual, la b\u00fasqueda de un <strong>venta de l\u00e1ser veterinario<\/strong> a menudo pone a los responsables de compras en contacto con una importante brecha tecnol\u00f3gica. Mientras que las b\u00fasquedas de <strong>el mejor aparato de terapia con l\u00e1ser fr\u00edo para uso dom\u00e9stico<\/strong> priorizar la seguridad y la sencillez, de grado cl\u00ednico <strong>l\u00e1ser veterinario<\/strong> debe abordar un conjunto mucho m\u00e1s complejo de variables biol\u00f3gicas: la atenuaci\u00f3n de la luz a trav\u00e9s de capas tisulares heterog\u00e9neas.<\/p>\n\n\n\n<p>The clinical efficacy of photobiomodulation (PBM) is governed by the delivery of a therapeutic dose of photons to the target chromophores\u2014specifically Cytochrome C Oxidase (CCO)\u2014within the mitochondria of deep-seated tissues. To achieve this in large canine or equine patients, the system must overcome the scattering coefficient ($\\mu_s$) and the absorption coefficient ($\\mu_a$) of the fur and epidermis. This is where the concept of <strong>Tasa de fluencia volum\u00e9trica<\/strong> se convierte en un factor cr\u00edtico. A diferencia de los dispositivos de baja potencia, los sistemas de Clase 4 de alta intensidad proporcionan la densidad de fotones necesaria para alcanzar una <strong>Profundidad biol\u00f3gica efectiva<\/strong> de 5 cm a 10 cm.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"372\" src=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/laser-therapy-for-horses101.jpg\" alt=\"\" class=\"wp-image-12636\" srcset=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/laser-therapy-for-horses101.jpg 400w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/laser-therapy-for-horses101-300x279.jpg 300w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/laser-therapy-for-horses101-13x12.jpg 13w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<p>Para modelizar la irradiancia en la profundidad $z$, utilizamos la aproximaci\u00f3n de difusi\u00f3n de la ecuaci\u00f3n de transporte radiativo:<\/p>\n\n\n\n<p>$$\\Phi(z) = \\Phi_0 \\cdot \\exp\\left(-z \\sqrt{3\\mu_a(\\mu_a + \\mu_s&#8217;)}\\right)$$<\/p>\n\n\n\n<p>Where $\\Phi_0$ is the incident irradiance at the surface and $\\mu_s&#8217;$ is the reduced scattering coefficient. Class 4 systems allow for a higher $\\Phi_0$, ensuring that the fluence at depth remains within the therapeutic window of 0.1 to 10 $W\/cm^2$, a threshold rarely met by lower-power alternatives.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sinergia de longitudes de onda m\u00faltiples: interacci\u00f3n de 1470 nm, 980 nm y 810 nm<\/h3>\n\n\n\n<p>Advanced clinical outcomes are no longer a result of single-wavelength emission. The integration of 1470nm and 980nm wavelengths\u2014specifically in units like the SurgMedix\u2014allows for a dual-action approach to soft tissue management. The 1470nm wavelength aligns with the peak absorption of water in the tissue, facilitating a <strong>Zona de ablaci\u00f3n controlada<\/strong> que es significativamente m\u00e1s preciso que el electrocauterio. Al mismo tiempo, la longitud de onda de 980 nm se dirige a la hemoglobina, lo que garantiza una hemostasia inmediata y reduce el riesgo de hematomas postoperatorios.<\/p>\n\n\n\n<p>Esta sinergia t\u00e9cnica se extiende a la rehabilitaci\u00f3n. En el VetMedix 3000U5, la inclusi\u00f3n de la longitud de onda de 1064 nm proporciona un menor coeficiente de dispersi\u00f3n, actuando como portador para alcanzar las estructuras anat\u00f3micas m\u00e1s profundas, como la articulaci\u00f3n de la cadera o el corvej\u00f3n equino. Este <strong>Fotobiomodulaci\u00f3n de tejidos profundos<\/strong> (DTP) es la clave para tratar afecciones degenerativas cr\u00f3nicas que no responden a tratamientos superficiales.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Est\u00e1ndares cl\u00ednicos comparativos: Intervenci\u00f3n convencional frente a protocolos l\u00e1ser de alta irradiaci\u00f3n<\/h3>\n\n\n\n<p>Para un distribuidor B2B o un cirujano jefe, la decisi\u00f3n de integrar la tecnolog\u00eda l\u00e1ser de alta potencia supone un avance hacia la eficiencia cl\u00ednica y operativa. La siguiente tabla cuantifica las ventajas de la integraci\u00f3n del l\u00e1ser de clase 4 frente a los m\u00e9todos quir\u00fargicos y terap\u00e9uticos tradicionales.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Par\u00e1metro cl\u00ednico<\/strong><\/td><td><strong>Electrocirug\u00eda tradicional \/ Acero fr\u00edo<\/strong><\/td><td><strong>Protocolo de Alta Intensidad Clase 4<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Zona de necrosis t\u00e9rmica<\/strong><\/td><td>1.0mm &#8211; 2.5mm (Collateral damage)<\/td><td>&lt; 0,2 mm (muy espec\u00edfico)<\/td><\/tr><tr><td><strong>Hemostasia intraoperatoria<\/strong><\/td><td>Manual (ligadura\/esponja)<\/td><td>Autom\u00e1tica (fotocoagulaci\u00f3n l\u00e1ser)<\/td><\/tr><tr><td><strong>Recuperaci\u00f3n postoperatoria<\/strong><\/td><td>Inflamaci\u00f3n elevada (dependiente de AINE)<\/td><td>Reducci\u00f3n del edema (efecto PBM inmediato)<\/td><\/tr><tr><td><strong>Velocidad del tratamiento<\/strong><\/td><td>20 &#8211; 30 Minutes (Low power)<\/td><td>5 &#8211; 10 Minutes (High power density)<\/td><\/tr><tr><td><strong>Precisi\u00f3n procesal<\/strong><\/td><td>Dependiente del contacto<\/td><td>Flexibilidad de fibra \u00f3ptica\/sin contacto<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Estudio de caso cl\u00ednico: Tratamiento complejo del s\u00edndrome navicular cr\u00f3nico en un caballo de deporte<\/h3>\n\n\n\n<p><strong>Antecedentes del paciente:<\/strong> Un caballo castrado Warmblood de 12 a\u00f1os, activo en salto de alto nivel, present\u00f3 cojera de grado 3\/5 en la extremidad anterior. Los tratamientos anteriores, que inclu\u00edan herrajes correctivos e inyecciones de corticosteroides, no hab\u00edan conseguido aliviarla a largo plazo.<\/p>\n\n\n\n<p><strong>Diagn\u00f3stico:<\/strong> S\u00edndrome Navicular Cr\u00f3nico con Desmitis asociada del Ligamento Impar y acumulaci\u00f3n de l\u00edquido dentro de la Bursa Navicular.<\/p>\n\n\n\n<p><strong>Intervenci\u00f3n terap\u00e9utica (HorseVet 3000U5):<\/strong><\/p>\n\n\n\n<p>El reto consist\u00eda en suministrar energ\u00eda suficiente a trav\u00e9s de la densa c\u00e1psula del casco y la almohadilla digital. Se dise\u00f1\u00f3 un protocolo de alto voltaje para suprimir la inflamaci\u00f3n neurog\u00e9nica y estimular la circulaci\u00f3n colateral.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Longitudes de onda:<\/strong> 810 nm (reparaci\u00f3n celular) y 1064 nm (penetraci\u00f3n profunda).<\/li>\n\n\n\n<li><strong>Potencia de salida:<\/strong> 20W, modo pulsado (ciclo de trabajo 50%).<\/li>\n\n\n\n<li><strong>Tama\u00f1o de la mancha:<\/strong> 30 mm (sin contacto).<\/li>\n\n\n\n<li><strong>Frecuencia del tratamiento:<\/strong> Cada 48 horas durante 2 semanas, seguido de mantenimiento.<\/li>\n<\/ul>\n\n\n\n<p><strong>Par\u00e1metros detallados del tratamiento:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Anatom\u00eda Dirigida<\/strong><\/td><td><strong>Modo<\/strong><\/td><td><strong>Potencia (W)<\/strong><\/td><td><strong>Frecuencia<\/strong><\/td><td><strong>Energ\u00eda total (J)<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Regi\u00f3n palmar del pie<\/td><td>Pulsado<\/td><td>20W<\/td><td>10 Hz<\/td><td>6000J<\/td><\/tr><tr><td>Banda coronaria<\/td><td>Continuo<\/td><td>15W<\/td><td>N\/A<\/td><td>3000J<\/td><\/tr><tr><td>Tend\u00f3n flexor digital<\/td><td>Pulsado<\/td><td>10W<\/td><td>20 Hz<\/td><td>2000J<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Recuperaci\u00f3n y resultados:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Semana 2:<\/strong> La cojera mejor\u00f3 al grado 1\/5. Las im\u00e1genes termogr\u00e1ficas mostraron una marcada reducci\u00f3n del calor localizado en el casco.<\/li>\n\n\n\n<li><strong>Semana 6:<\/strong> El caballo volvi\u00f3 al entrenamiento ligero. La resonancia magn\u00e9tica de seguimiento mostr\u00f3 una reducci\u00f3n significativa del derrame bursal y un aumento de la organizaci\u00f3n del patr\u00f3n de fibras en el ligamento impar.<\/li>\n\n\n\n<li><strong>Conclusi\u00f3n:<\/strong> La elevada potencia de pico del sistema de clase 4 era necesaria para alcanzar el aparato navicular, una profundidad en la que los dispositivos de uso dom\u00e9stico ser\u00edan f\u00edsicamente incapaces de administrar una dosis terap\u00e9utica.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Integridad t\u00e9cnica: Mantenimiento y seguridad en un ecosistema B2B<\/h3>\n\n\n\n<p>For hospital procurement teams, the &#8220;Total Cost of Ownership&#8221; is inextricably linked to the durability of the diode stack. Unlike consumer-focused products, professional <strong>l\u00e1ser veterinario<\/strong> requieren una gesti\u00f3n t\u00e9rmica sofisticada. Nuestros sistemas emplean un <strong>Arquitectura de refrigeraci\u00f3n de circuito cerrado<\/strong> que controla la temperatura de uni\u00f3n del diodo en tiempo real. Si la temperatura del diodo fluct\u00faa, el sistema ajusta autom\u00e1ticamente la corriente para evitar la desviaci\u00f3n de la longitud de onda, que de otro modo podr\u00eda dar lugar a resultados cl\u00ednicos incoherentes.<\/p>\n\n\n\n<p><strong>Protocolos de mantenimiento y seguridad:<\/strong><\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Calibraci\u00f3n de fibra \u00f3ptica:<\/strong> Professional surgical fibers are consumables that require inspection. A degraded fiber end-piece can result in &#8220;Beam Divergence,&#8221; reducing the irradiance and potentially causing burns due to energy scattering.<\/li>\n\n\n\n<li><strong>Recertificaci\u00f3n de calibraci\u00f3n:<\/strong> La calibraci\u00f3n anual de potencia con trazabilidad NIST es esencial. Esto garantiza que los 15 W mostrados en la interfaz de usuario son exactamente los que recibe el paciente, lo cual es crucial para la investigaci\u00f3n cl\u00ednica y la documentaci\u00f3n de reembolso de las aseguradoras.<\/li>\n\n\n\n<li><strong>Seguridad ocular y NOHD:<\/strong> La Distancia Nominal de Peligro Ocular para un sistema de Clase 4 es significativa. Las cl\u00ednicas deben designar una zona de l\u00e1ser controlado (LCA) con se\u00f1alizaci\u00f3n adecuada de OD 5+ y gafas de protecci\u00f3n para todo el personal y los pacientes animales.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Perspectivas de futuro: El papel de la dosimetr\u00eda adaptativa<\/h3>\n\n\n\n<p>A medida que nos adentramos en la nueva era de la fotomedicina, la atenci\u00f3n se centra en los siguientes aspectos <strong>Dosimetr\u00eda adaptativa<\/strong>. Future systems from Fotonmedix are incorporating AI-driven sensors that measure the reflection coefficient of the animal&#8217;s coat and skin in real-time. This allows the device to automatically adjust the power output to maintain a constant <strong>Flujo de irradiaci\u00f3n<\/strong> at the target tissue, regardless of the patient&#8217;s color or coat density.<\/p>\n\n\n\n<p>Para el agente regional o el propietario de una cl\u00ednica, invertir en una plataforma de este tipo no consiste simplemente en adquirir hardware, sino en adoptar un sistema modular de suministro de energ\u00eda que crezca con la evoluci\u00f3n de los est\u00e1ndares de la cirug\u00eda y la rehabilitaci\u00f3n veterinarias.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">FAQ profesionales: Preocupaciones operativas<\/h3>\n\n\n\n<p><strong>P: \u00bfPueden utilizarse con seguridad estos sistemas de alta potencia en pacientes felinos peque\u00f1os?<\/strong><\/p>\n\n\n\n<p>A: Yes. While the peak power is high, the software allows for granular control. By utilizing the &#8220;Super-Pulsed&#8221; mode, you can deliver high peak energy for deep penetration while keeping the average power low enough to prevent thermal discomfort in small patients.<\/p>\n\n\n\n<p><strong>P: \u00bfPor qu\u00e9 se prefiere un l\u00e1ser de clase 4 a uno de clase 3b para la artritis cr\u00f3nica?<\/strong><\/p>\n\n\n\n<p>R: Tiempo y profundidad. Un l\u00e1ser de clase 3b necesitar\u00eda 30-40 minutos para suministrar la misma energ\u00eda que un sistema de clase 4 suministra en 5 minutos. Adem\u00e1s, la densidad de fotones de un l\u00e1ser de clase 4 es t\u00e9cnicamente necesaria para superar el coeficiente de dispersi\u00f3n de los tejidos articulares profundos.<\/p>\n\n\n\n<p><strong>P: \u00bfCu\u00e1l es la vida \u00fatil de los m\u00f3dulos de diodos Fotonmedix?<\/strong><\/p>\n\n\n\n<p>R: Nuestras pilas de diodos de calidad industrial tienen una vida \u00fatil de m\u00e1s de 20.000 horas. Con una refrigeraci\u00f3n adecuada y una calibraci\u00f3n rutinaria, estos sistemas son un activo cl\u00ednico a largo plazo con un alto retorno de la inversi\u00f3n.<\/p>","protected":false},"excerpt":{"rendered":"<p>High-irradiance Class 4 systems optimize the mitochondrial absorption cross-section, ensuring deep tissue photon flux through dense dermal layers to accelerate ATP synthesis, provide instantaneous neuro-modulation for analgesia, and achieve precise photothermal hemostasis in complex surgical environments. The Physics of Penetration: Overcoming the Limitations of Low-Power Modalities In the current medical landscape, the search for a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":"","_wpscp_schedule_draft_date":"","_wpscp_schedule_republish_date":"","_wpscppro_advance_schedule":false,"_wpscppro_advance_schedule_date":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"default","_threads_share_type":"default","_google_business_share_type":"default","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[19],"tags":[816,819],"class_list":["post-12635","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-laser-therapy-device","tag-cold-laser-therapy"],"metadata":{"_facebook_share_type":["default"],"_twitter_share_type":["default"],"_linkedin_share_type":["default"],"_pinterest_share_type":["default"],"_instagram_share_type":["default"],"_medium_share_type":["default"],"_threads_share_type":["default"],"_google_business_share_type":["default"],"_wpsp_custom_templates":["a:7:{s:8:\"facebook\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:7:\"twitter\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:8:\"linkedin\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:9:\"pinterest\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:9:\"instagram\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:6:\"medium\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:7:\"threads\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}}"],"_edit_lock":["1775550990:1"],"_wpsp_social_scheduling":["a:11:{s:7:\"enabled\";b:0;s:8:\"datetime\";N;s:9:\"platforms\";a:0:{}s:6:\"status\";s:13:\"template_only\";s:10:\"dateOption\";s:5:\"today\";s:10:\"timeOption\";s:3:\"now\";s:10:\"customDays\";s:0:\"\";s:11:\"customHours\";s:0:\"\";s:10:\"customDate\";s:0:\"\";s:10:\"customTime\";s:0:\"\";s:14:\"schedulingType\";s:8:\"absolute\";}"],"wpil_sync_report3":["1"],"themepark_post_bcolor":["#f5f5f5"],"themepark_post_width":["1022px"],"themepark_post_img":[""],"themepark_post_img_po":["left"],"themepark_post_img_re":[""],"themepark_post_img_cover":[""],"themepark_post_img_fixed":[""],"themepark_post_hide_title":[""],"themepark_post_main_b":[""],"themepark_post_main_p":["100"],"themepark_paddingblock":[""],"footnotes":[""],"_wpscp_schedule_draft_date":[""],"_wpscp_schedule_republish_date":[""],"_wpscppro_advance_schedule_date":[""],"_wpscppro_dont_share_socialmedia":[""],"_wpscppro_custom_social_share_image":["0"],"_linkedin_share_type_page":["default"],"_selected_social_profile":["a:0:{}"],"_wpsp_enable_custom_social_template":[""],"_wpsp_active_default_template":["1"],"_edit_last":["1"],"_aioseo_title":["High-Performance Veterinary Lasers for Sale | Fotonmedix"],"_aioseo_description":["Compare professional veterinary lasers with home-use cold laser devices. Technical insights on Class 4 PBM, surgical precision, and equine recovery protocols."],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"catce":["sidebar-widgets4"],"views":["41"]},"aioseo_notices":[],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/12635","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/comments?post=12635"}],"version-history":[{"count":1,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/12635\/revisions"}],"predecessor-version":[{"id":12637,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/12635\/revisions\/12637"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/media?parent=12635"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/categories?post=12635"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/tags?post=12635"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}