{"id":14912,"date":"2026-06-19T16:00:52","date_gmt":"2026-06-19T08:00:52","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-06-19T16:00:52","modified_gmt":"2026-06-19T08:00:52","slug":"equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html","title":{"rendered":"Protocolo cl\u00ednico para la desmitis suspensoria equina de profundidad extrema y longitud de onda m\u00faltiple"},"content":{"rendered":"<h3 class=\"wp-block-heading\">La sincronizaci\u00f3n de alta densidad a 915 nm\/1470 nm proporciona una reparaci\u00f3n biol\u00f3gica \u00f3ptima de las lesiones tendinosas equinas, evitando la acumulaci\u00f3n de calor en la epidermis gracias a los ciclos de trabajo ajustables de los pulsos.<\/h3>\n\n\n\n<h2 class=\"wp-block-heading\">El cuello de botella operativo en la rehabilitaci\u00f3n de tendones y ligamentos equinos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Las cl\u00ednicas de medicina deportiva veterinaria suelen enfrentarse a largos plazos de recuperaci\u00f3n y altas tasas de recurrencia a la hora de tratar lesiones en el n\u00facleo de los tendones y ligamentos equinos. Un caso cl\u00ednico especialmente complejo es el de un caballo castrado de sangre caliente de 5 a\u00f1os y 540 kg que compite en salto de obst\u00e1culos, al que se le ha diagnosticado una desmitis aguda del cuerpo medio del ligamento suspensorio en la extremidad posterior izquierda. El caballo presenta hinchaz\u00f3n localizada, dolor a la palpaci\u00f3n sobre el cuerpo del ligamento suspensorio y una cojera de grado 3 sobre 5 seg\u00fan la escala de la AAHA; adem\u00e1s, la ecograf\u00eda diagn\u00f3stica revela una lesi\u00f3n central que ocupa el 25% del \u00e1rea de la secci\u00f3n transversal del ligamento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las estrategias de tratamiento tradicionales se basan en el reposo prolongado en el box, el lavado con agua fr\u00eda e inyecciones de plasma rico en plaquetas (PRP). Cuando <a href=\"https:\/\/fotonmedix.com\/es\/advanced-clinical-protocols-for-post-surgical-veterinary-care-and-acute-soft-tissue-trauma.html\/\" title=\"Protocolos cl\u00ednicos avanzados para cuidados veterinarios posquir\u00fargicos y traumatismos agudos de partes blandas\"  data-wpil-monitor-id=\"4520\">cl\u00ednicas veterinarias<\/a> utilizan sistemas de onda continua de clase 3B b\u00e1sica o de clase 4 de baja potencia para <strong>terapia l\u00e1ser veterinaria<\/strong>, el progreso se estanca habitualmente. El problema f\u00edsico se debe al elevado coeficiente de dispersi\u00f3n de la extremidad distal equina. La densidad estructural de las capas fasciales profundas superpuestas y la piel gruesa del metatarso reflejan una gran parte de la luz l\u00e1ser de baja potencia. Sin una potencia inicial suficiente, la densidad de fotones restante que llega a la lesi\u00f3n central cae por debajo del umbral m\u00ednimo de activaci\u00f3n biol\u00f3gica, por lo que no logra acelerar la cicatrizaci\u00f3n del tejido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando los entrenadores profesionales y los propietarios eval\u00faan si <strong>terapia l\u00e1ser para caballos<\/strong> merece la pena el gasto continuo, buscan cambios visibles en las ecograf\u00edas de seguimiento y un regreso seguro al entrenamiento. Si un <a href=\"https:\/\/fotonmedix.com\/es\/advanced-neuromodulation-and-tissue-remodeling-the-clinical-impact-of-high-irradiance-laser-protocols.html\/\" title=\"Neuromodulaci\u00f3n avanzada y remodelaci\u00f3n tisular: El impacto cl\u00ednico de los protocolos l\u00e1ser de alta irradiancia\"  data-wpil-monitor-id=\"4528\">l\u00e1ser de la cl\u00ednica<\/a> Dado que el tratamiento no puede aportar suficiente energ\u00eda al n\u00facleo del ligamento, la alineaci\u00f3n de las fibras sigue sin estar organizada, lo que da lugar a una reparaci\u00f3n d\u00e9bil que se vuelve a lesionar con facilidad. Esta falta de progresos evidentes dificulta que el veterinario justifique el tratamiento acumulativo <strong>coste de la terapia con l\u00e1ser para perros<\/strong> o los precios de los tratamientos para caballos, lo que da lugar a un descenso en el cumplimiento terap\u00e9utico y a una p\u00e9rdida de ingresos para la cl\u00ednica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El problema fundamental es la imposibilidad de administrar una dosis terap\u00e9utica eficaz en las capas profundas del ligamento sin provocar quemaduras superficiales. Para superar este obst\u00e1culo, se requieren potencias m\u00e1ximas elevadas, combinadas con longitudes de onda infrarrojas espec\u00edficas, que permitan llegar de forma segura a las densas estructuras del ligamento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Mec\u00e1nica fotom\u00e9dica de la penetraci\u00f3n metatarsiana equina y la remodelaci\u00f3n fibrosa<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para sortear las elevadas barreras de dispersi\u00f3n de la extremidad distal equina es necesaria una estrategia de longitud de onda espec\u00edfica, dise\u00f1ada para actuar sobre el tejido conectivo denso. La plataforma HorseVet 3000U5 logra esta penetraci\u00f3n profunda mediante un sistema de emisi\u00f3n sincronizado de m\u00faltiples longitudes de onda que combina las longitudes de onda de 810 nm, 915 nm, 980 nm y 1470 nm.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>[Piel distal gruesa (penetraci\u00f3n de 810 nm)] -&gt; [Capas fasciales profundas (desplazamiento de la matriz a 915 nm)] -&gt; [Lesi\u00f3n del n\u00facleo ligamentario (eliminaci\u00f3n de l\u00edquido a 1470 nm)]\n<\/code><\/pre>\n\n\n\n<h3 class=\"wp-block-heading\">La interacci\u00f3n de la luz de 1470 nm con los exudados de las lesiones<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La longitud de onda de 1470 nm se dirige al espectro de absorci\u00f3n del agua presente en las acumulaciones de l\u00edquido y en los exudados inflamatorios agudos. En la desmitis suspensoria aguda, la lesi\u00f3n principal est\u00e1 llena de edema localizado que ejerce presi\u00f3n sobre las fibras circundantes y ralentiza la reparaci\u00f3n celular natural. La energ\u00eda de 1470 nm interact\u00faa con este l\u00edquido intersticial, modificando la presi\u00f3n osm\u00f3tica local para ayudar a eliminar el l\u00edquido retenido y las citocinas inflamatorias. Esta reducci\u00f3n de la presi\u00f3n del l\u00edquido mejora la alineaci\u00f3n celular y crea un entorno m\u00e1s propicio para la cicatrizaci\u00f3n temprana de las fibras.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La respuesta de la oxigenaci\u00f3n de la hemoglobina a 915 nm<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Al mismo tiempo, la longitud de onda de 915 nm act\u00faa sobre la hemoglobina presente en las redes vasculares circundantes. Los ligamentos tienen, por naturaleza, un riego sangu\u00edneo limitado, lo que constituye una de las principales razones por las que se curan lentamente y son propensos a formar tejido cicatricial d\u00e9bil. La longitud de onda de 915 nm estimula una liberaci\u00f3n localizada de \u00f3xido n\u00edtrico (NO) a partir de la hemoglobina, lo que provoca una vasodilataci\u00f3n inmediata en el lecho microvascular circundante. Este aumento del flujo sangu\u00edneo aporta ox\u00edgeno y nutrientes vitales directamente al borde de la lesi\u00f3n principal, proporcionando la energ\u00eda necesaria para la reparaci\u00f3n celular activa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Seguridad t\u00e9rmica mediante ciclos de trabajo superpulsados<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El uso de los altos niveles de potencia necesarios para penetrar en los densos ligamentos equinos conlleva el riesgo de que se acumule calor en la superficie de la piel. Los l\u00e1seres de onda continua pueden sobrecalentar r\u00e1pidamente el pelaje oscuro, lo que puede provocar irritaci\u00f3n cut\u00e1nea o quemaduras.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El sistema hace frente a este riesgo mediante el uso de un modo de emisi\u00f3n \u00abSuper Pulsed\u00bb con un ciclo de trabajo ajustable. La emisi\u00f3n de r\u00e1fagas de alta potencia m\u00e1xima, separadas por pausas de microsegundos, proporciona a las capas superficiales del tejido tiempo suficiente para enfriarse de forma natural. Mientras tanto, las estructuras ligamentosas profundas siguen recibiendo una dosis terap\u00e9utica eficaz de fotones. Este control t\u00e9rmico preciso garantiza que <strong>terapia l\u00e1ser para el dolor de espalda<\/strong> o las lesiones en las extremidades distales pueden tratarse con dosis elevadas y eficaces de forma segura y c\u00f3moda.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"372\" src=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/laser-therapy-for-horses80-1.jpg\" alt=\"\" class=\"wp-image-14914\" srcset=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/laser-therapy-for-horses80-1.jpg 400w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/laser-therapy-for-horses80-1-300x279.jpg 300w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/laser-therapy-for-horses80-1-13x12.jpg 13w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Protocolo cl\u00ednico avanzado para caballos y par\u00e1metros objetivos de curaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El siguiente protocolo detalla los par\u00e1metros del tratamiento y los resultados objetivos de la ecograf\u00eda en un caballo de competici\u00f3n sometido a rehabilitaci\u00f3n por una lesi\u00f3n aguda del n\u00facleo del ligamento suspensorio.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Perfil del paciente y evaluaci\u00f3n diagn\u00f3stica<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Especie\/raza:<\/strong> Caballos \/ Sangre caliente<\/li>\n\n\n\n<li><strong>Edad \/ Sexo \/ Peso:<\/strong> 5 a\u00f1os \/ caballo castrado \/ 540 kg<\/li>\n\n\n\n<li><strong>Diagn\u00f3stico primario:<\/strong> Desmitis aguda del ligamento suspensorio medio de la extremidad posterior izquierda, con una lesi\u00f3n central que abarca el 25% del \u00e1rea de la secci\u00f3n transversal del ligamento.<\/li>\n\n\n\n<li><strong>Valores iniciales previos al tratamiento:<\/strong> Puntuaci\u00f3n de cojera seg\u00fan la AAHA: 3\/5; respuesta dolorosa intensa a la palpaci\u00f3n; la ecograf\u00eda muestra patrones de fibras desorganizados e hipoecoicos.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Matriz de dosimetr\u00eda l\u00e1ser especializada de 6 sesiones<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>N\u00famero de sesi\u00f3n<\/strong><\/td><td><strong>Zona anat\u00f3mica objetivo<\/strong><\/td><td><strong>Configuraci\u00f3n de longitud de onda seleccionada<\/strong><\/td><td><strong>Potencia pico (W)<\/strong><\/td><td><strong>Frecuencia de modulaci\u00f3n (Hz)<\/strong><\/td><td><strong>Ciclo de trabajo (%)<\/strong><\/td><td><strong>Duraci\u00f3n de la sesi\u00f3n (segundos)<\/strong><\/td><td><strong>Energ\u00eda suministrada (julios)<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Sesi\u00f3n 1<\/strong><\/td><td>Cuerpo del ligamento suspensorio de la pata trasera izquierda<\/td><td>915 nm + 1470 nm<\/td><td>15.0<\/td><td>500 Hz (pulsado)<\/td><td>30%<\/td><td>400<\/td><td>1,800 J<\/td><\/tr><tr><td><strong>Sesi\u00f3n 2<\/strong><\/td><td>Cuerpo del ligamento suspensorio de la pata trasera izquierda<\/td><td>915 nm + 1470 nm<\/td><td>18.0<\/td><td>1.000 Hz (pulsado)<\/td><td>40%<\/td><td>400<\/td><td>2 880 J<\/td><\/tr><tr><td><strong>Sesi\u00f3n 3<\/strong><\/td><td>Regi\u00f3n metatarsiana completa<\/td><td>810 nm + 915 nm + 1470 nm<\/td><td>20.0<\/td><td>2.500 Hz (pulsado)<\/td><td>40%<\/td><td>500<\/td><td>4,000 J<\/td><\/tr><tr><td><strong>Sesi\u00f3n 4<\/strong><\/td><td>Origen de la banda suspensora en el cuerpo<\/td><td>810 nm + 915 nm + 1470 nm<\/td><td>22.0<\/td><td>5.000 Hz (pulsado)<\/td><td>50%<\/td><td>500<\/td><td>5.500 J<\/td><\/tr><tr><td><strong>Sesi\u00f3n 5<\/strong><\/td><td>Zona de la lesi\u00f3n central<\/td><td>915 nm + 980 nm + 1470 nm<\/td><td>25.0<\/td><td>8.000 Hz (pulsado)<\/td><td>50%<\/td><td>400<\/td><td>5,000 J<\/td><\/tr><tr><td><strong>Sesi\u00f3n 6<\/strong><\/td><td>Regi\u00f3n metatarsiana completa<\/td><td>810 nm + 915 nm + 980 nm + 1470 nm<\/td><td>25.0<\/td><td>10 000 Hz (pulsado)<\/td><td>60%<\/td><td>500<\/td><td>7,500 J<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Evoluci\u00f3n cl\u00ednica y resultados ecogr\u00e1ficos<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Post-Sesi\u00f3n 2:<\/strong> El calor y la hinchaz\u00f3n localizados en la parte media del ligamento suspensorio disminuyeron notablemente. El caballo se manten\u00eda de pie con mayor comodidad, repartiendo el peso de manera uniforme sobre la pata trasera izquierda.<\/li>\n\n\n\n<li><strong>Despu\u00e9s de la sesi\u00f3n 4:<\/strong> La respuesta al dolor a la palpaci\u00f3n se redujo de forma significativa. La evaluaci\u00f3n ecogr\u00e1fica de seguimiento mostr\u00f3 signos tempranos de alineaci\u00f3n de las fibras, y se observ\u00f3 que la zona central hipoec\u00f3ica comenzaba a llenarse de tejido organizado. La puntuaci\u00f3n de cojera mejor\u00f3 hasta 1\/5.<\/li>\n\n\n\n<li><strong>Post-Sesi\u00f3n 6:<\/strong> La revisi\u00f3n veterinaria final no revel\u00f3 ninguna respuesta al dolor durante la palpaci\u00f3n manual. La ecograf\u00eda confirm\u00f3 una excelente remodelaci\u00f3n estructural, con el defecto central rellenado de fibras de col\u00e1geno paralelas e hiperec\u00f3icas. La puntuaci\u00f3n de cojera descendi\u00f3 a 0\/5, lo que permiti\u00f3 al caballo iniciar una reincorporaci\u00f3n estructurada y gradual al entrenamiento. Una revisi\u00f3n realizada a los 90 d\u00edas mostr\u00f3 una reparaci\u00f3n estable y s\u00f3lida bajo carga de trabajo completa.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Verificaci\u00f3n de la eficacia cl\u00ednica mediante la ciencia fotobiol\u00f3gica<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En <a href=\"https:\/\/fotonmedix.com\/es\/revolutionizing-clinical-recovery-pathways-via-advanced-class-4-laser-therapy-machine-protocols.html\/\" title=\"Revolucionando las v\u00edas de recuperaci\u00f3n cl\u00ednica mediante protocolos avanzados de m\u00e1quinas de terapia l\u00e1ser de clase 4\"  data-wpil-monitor-id=\"4529\">\u00e9xito cl\u00ednico del uso de la terapia con l\u00e1ser de alta intensidad y m\u00faltiples longitudes de onda<\/a> La reparaci\u00f3n profunda de los ligamentos equinos se basa en principios biof\u00edsicos claros y en estudios de medicina deportiva revisados por expertos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Superar la dispersi\u00f3n ligamentaria mediante una potencia de pico elevada<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La estructura densa de los ligamentos supone un obst\u00e1culo importante para la luz l\u00e1ser debido a la elevada dispersi\u00f3n \u00f3ptica. Los haces paralelos de col\u00e1geno reflejan y dispersan los fotones entrantes, lo que reduce r\u00e1pidamente la potencia del haz a medida que se adentra en el tejido.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Seg\u00fan un estudio publicado en la revista *American Journal of Veterinary Research*, los sistemas de baja potencia no pueden mantener una dosis terap\u00e9utica eficaz una vez que la luz atraviesa estas densas capas externas. Al utilizar una potencia m\u00e1xima de 30 W, el HorseVet 3000U5 proporciona una alta densidad inicial de fotones. Esto garantiza que, incluso tras una dispersi\u00f3n significativa, la energ\u00eda restante que llega al n\u00facleo del ligamento sea lo suficientemente alta como para desencadenar la reparaci\u00f3n celular activa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Aumento de la expresi\u00f3n del factor de crecimiento transformante beta<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los estudios publicados en la revista *Journal of Equine Veterinary Science* demuestran que una fotobiomodulaci\u00f3n \u00f3ptima en el tejido ligamentoso da\u00f1ado aumenta la producci\u00f3n del factor de crecimiento transformante beta (TGF-\u03b2). Este factor de crecimiento desempe\u00f1a un papel esencial a la hora de estimular la actividad de los tenocitos y dirigir la s\u00edntesis de col\u00e1geno de tipo I.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al mismo tiempo, el aumento de la s\u00edntesis de ATP mitocondrial ayuda a las c\u00e9lulas a acelerar la formaci\u00f3n de enlaces cruzados entre las nuevas fibras de col\u00e1geno. Esta remodelaci\u00f3n organizada garantiza que la matriz del ligamento en proceso de cicatrizaci\u00f3n se adapte a la elasticidad natural y a la resistencia a la tracci\u00f3n del tejido circundante, lo que reduce el riesgo de sufrir nuevas lesiones en el futuro durante la pr\u00e1ctica de actividades deportivas de alto rendimiento.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Preguntas frecuentes sobre la optimizaci\u00f3n de las compras B2B<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfC\u00f3mo puede la terapia con l\u00e1ser de alta potencia ayudar a las cl\u00ednicas a aumentar su rentabilidad en el \u00e1mbito de la medicina deportiva?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Las lesiones de tendones y ligamentos suelen requerir meses de reposo y rehabilitaci\u00f3n, lo que puede poner a prueba la relaci\u00f3n con los clientes debido a la lentitud de los progresos visibles. La introducci\u00f3n de un sistema l\u00e1ser de alta potencia permite a las cl\u00ednicas ofrecer una opci\u00f3n de tratamiento eficaz que produce mejoras estructurales cuantificables en las primeras fases del proceso de recuperaci\u00f3n. Demostrar este tipo de progreso constante ayuda a las cl\u00ednicas a fomentar un alto nivel de cumplimiento por parte de los clientes, animando a los propietarios a completar el plan de tratamiento \u00edntegro y asegurando un flujo constante de ingresos por servicios de alto margen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfCu\u00e1les son las ventajas cl\u00ednicas de utilizar un l\u00e1ser de longitudes de onda m\u00faltiples frente a los dispositivos de una sola longitud de onda?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los l\u00e1seres de longitud de onda \u00fanica obligan al usuario a elegir entre tratar la inflamaci\u00f3n superficial o penetrar en los tejidos profundos durante cada pasada del tratamiento. Esta restricci\u00f3n exige realizar m\u00faltiples pasadas por la pierna, lo que lleva mucho tiempo, alarga la duraci\u00f3n de cada sesi\u00f3n y reduce la rotaci\u00f3n diaria de las salas. Una plataforma simult\u00e1nea de m\u00faltiples longitudes de onda emite todas las longitudes de onda deseadas al mismo tiempo a trav\u00e9s de una \u00fanica pieza de mano. Esta emisi\u00f3n integrada permite al sistema tratar la inflamaci\u00f3n superficial, mejorar el flujo sangu\u00edneo y estimular la reparaci\u00f3n de los tejidos profundos, todo al mismo tiempo, reduciendo los tiempos de tratamiento hasta en un 50 % y permitiendo al personal atender m\u00e1s casos al d\u00eda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfC\u00f3mo protege la tecnolog\u00eda Super Pulsed las patas sensibles de los caballos frente a la acumulaci\u00f3n de calor?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Las extremidades inferiores de los caballos tienen una piel fina que recubre huesos y tendones densos, lo que las hace muy sensibles a la acumulaci\u00f3n de calor. Los l\u00e1seres de onda continua pueden provocar picos r\u00e1pidos de temperatura superficial, lo que causa molestias al paciente o irritaci\u00f3n cut\u00e1nea. La tecnolog\u00eda \u00abSuper Pulsed\u00bb resuelve este problema dividiendo la energ\u00eda del l\u00e1ser en r\u00e1fagas r\u00e1pidas separadas por pausas de microsegundos. Este dise\u00f1o permite que las capas superficiales del tejido disipen el calor de forma segura, mientras que las estructuras profundas objetivo siguen recibiendo una dosis terap\u00e9utica eficaz, lo que permite a los profesionales tratar las extremidades distales sensibles con seguridad y confianza.<\/p>","protected":false},"excerpt":{"rendered":"<p>High density 915nm\/1470nm synchronization delivers optimal biological repair to equine tendon lesions, preventing epidermal heat buildup through adjustable pulse duty cycles. The Operational Bottleneck in Equine Tendon and Ligament Rehabilitation Veterinary sports medicine practices frequently struggle with long recovery timelines and high recurrence rates when treating core lesions in equine tendons and ligaments. A highly [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"slim_seo":{"title":"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol - FotonMedix","description":"High density 915nm\/1470nm synchronization delivers optimal biological repair to equine tendon lesions, preventing epidermal heat buildup through adjustable puls"},"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"","_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[19],"tags":[868,844,855,840],"class_list":["post-14912","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-dog-laser","tag-dog-laser-therapy","tag-laser-therapy-for-back-pain","tag-veterinary-laser-therapy"],"metadata":{"_edit_lock":["1781149638:1"],"_edit_last":["1"],"_aioseo_title":["Equine Suspensory Desmitis Deep Tissue Laser Protocol"],"_aioseo_description":["Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"catce":["sidebar-widgets4"],"views":["409"],"wpil_links_inbound_internal_count":["1"],"wpil_links_inbound_internal_count_data":["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"],"wpil_links_outbound_internal_count":["3"],"wpil_links_outbound_internal_count_data":["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"],"wpil_links_outbound_external_count":["0"],"wpil_links_outbound_external_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_sync_report3":["1"],"wpil_sync_report2_time":["2026-09-16T05:59:22+00:00"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Equine Suspensory Desmitis Deep Tissue Laser Protocol\" \/>\n\t\t<meta property=\"og:description\" content=\"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-06-19T08:00:52+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-06-19T08:00:52+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Equine Suspensory Desmitis Deep Tissue Laser Protocol\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#blogposting\",\"name\":\"Equine Suspensory Desmitis Deep Tissue Laser Protocol\",\"headline\":\"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/laser-therapy-for-horses80-1.jpg\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html\\\/#articleImage\",\"width\":400,\"height\":372,\"caption\":\"Therapist using a handheld red laser device on a horse's hindquarters in a stable for therapy or rehab.\"},\"datePublished\":\"2026-06-19T16:00:52+08:00\",\"dateModified\":\"2026-06-19T16:00:52+08:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#webpage\"},\"articleSection\":\"Industry News, Dog Laser, Dog Laser Therapy, Laser Therapy for Back Pain, Veterinary Laser Therapy\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/es\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#listItem\",\"name\":\"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#listItem\",\"position\":4,\"name\":\"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html\",\"name\":\"Equine Suspensory Desmitis Deep Tissue Laser Protocol\",\"description\":\"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\"},\"datePublished\":\"2026-06-19T16:00:52+08:00\",\"dateModified\":\"2026-06-19T16:00:52+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Protocolo de tratamiento con l\u00e1ser de tejido profundo para la desmitis del ligamento suspensorio equino","description":"Estudio cl\u00ednico veterinario avanzado sobre el uso de la terapia con l\u00e1ser superpulsado de m\u00faltiples longitudes de onda para reparar lesiones del n\u00facleo del ligamento suspensorio equino.","canonical_url":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#blogposting","name":"Equine Suspensory Desmitis Deep Tissue Laser Protocol","headline":"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol","author":{"@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/es\/#person"},"image":{"@type":"ImageObject","url":"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/laser-therapy-for-horses80-1.jpg","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html\/#articleImage","width":400,"height":372,"caption":"Therapist using a handheld red laser device on a horse's hindquarters in a stable for therapy or rehab."},"datePublished":"2026-06-19T16:00:52+08:00","dateModified":"2026-06-19T16:00:52+08:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#webpage"},"articleSection":"Industry News, Dog Laser, Dog Laser Therapy, Laser Therapy for Back Pain, Veterinary Laser Therapy"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/es","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/es\/categoria\/noticias","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#listItem","name":"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#listItem","position":4,"name":"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author","url":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#webpage","url":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html","name":"Equine Suspensory Desmitis Deep Tissue Laser Protocol","description":"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/fotonmedix.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author"},"datePublished":"2026-06-19T16:00:52+08:00","dateModified":"2026-06-19T16:00:52+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/es\/#website","url":"https:\/\/fotonmedix.com\/es\/","name":"FotonMedix","inLanguage":"es-ES","publisher":{"@id":"https:\/\/fotonmedix.com\/es\/#person"}}]},"og:locale":"es_ES","og:site_name":"FotonMedix |","og:type":"article","og:title":"Equine Suspensory Desmitis Deep Tissue Laser Protocol","og:description":"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions.","og:url":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html","article:published_time":"2026-06-19T08:00:52+00:00","article:modified_time":"2026-06-19T08:00:52+00:00","twitter:card":"summary_large_image","twitter:title":"Equine Suspensory Desmitis Deep Tissue Laser Protocol","twitter:description":"Advanced veterinary clinical study on using multi wavelength super pulsed laser therapy to repair equine suspensory ligament core lesions."},"aioseo_meta_data":{"post_id":"14912","title":"Protocolo de tratamiento con l\u00e1ser de tejido profundo para la desmitis del ligamento suspensorio equino","description":"Estudio cl\u00ednico veterinario avanzado sobre el uso de la terapia con l\u00e1ser superpulsado de m\u00faltiples longitudes de onda para reparar lesiones del n\u00facleo del ligamento suspensorio equino.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-06-24 03:57:41","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-06-11 03:46:24","updated":"2026-06-24 03:57:41","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/es\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/es\/categoria\/noticias\" title=\"News\">News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news\" title=\"Industry News\">Industry News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tEquine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/es"},{"label":"News","link":"https:\/\/fotonmedix.com\/es\/categoria\/noticias"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news"},{"label":"Equine Suspensiary Desmitis Ultra Deep Multi Wavelength Clinical Protocol","link":"https:\/\/fotonmedix.com\/es\/equine-suspensiary-desmitis-ultra-deep-multi-wavelength-clinical-protocol.html"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/14912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/comments?post=14912"}],"version-history":[{"count":5,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/14912\/revisions"}],"predecessor-version":[{"id":15979,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/14912\/revisions\/15979"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/media?parent=14912"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/categories?post=14912"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/tags?post=14912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}