{"id":16597,"date":"2026-07-31T19:30:02","date_gmt":"2026-07-31T11:30:02","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-07-31T19:30:02","modified_gmt":"2026-07-31T11:30:02","slug":"clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html","title":{"rendered":"Los profesionales sanitarios combaten el da\u00f1o t\u00e9rmico en los tejidos profundos mediante m\u00faltiples longitudes de onda"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Fotobiomodulaci\u00f3n de alta potencia y doble longitud de onda para acelerar la recuperaci\u00f3n musculoesquel\u00e9tica profunda<\/h2>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Resumen ejecutivo:<\/strong> La emisi\u00f3n de doble longitud de onda (1470 nm + 980 nm) optimiza el perfil de distribuci\u00f3n de fotones. Mediante el uso de un ciclo de trabajo 50% a 30 W, el sistema logra la m\u00e1xima estimulaci\u00f3n del ATP en los tejidos profundos sin ning\u00fan riesgo t\u00e9rmico.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">El dilema de la penetraci\u00f3n en los tejidos profundos en la fisioterapia moderna<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los profesionales de la rehabilitaci\u00f3n ortop\u00e9dica y la medicina deportiva veterinaria se enfrentan con frecuencia a un obst\u00e1culo frustrante: la barrera cut\u00e1nea humana o equina act\u00faa como un reflector y absorbedor de energ\u00eda lum\u00ednica muy eficaz. Al utilizar un <strong>m\u00e1quina de terapia l\u00e1ser<\/strong>, gran parte de la luz emitida se pierde en la melanina de la epidermis y en las mol\u00e9culas de agua de la dermis superficial. Esta p\u00e9rdida de energ\u00eda no solo es ineficaz, sino que adem\u00e1s resulta cl\u00ednicamente peligrosa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando un profesional sanitario intenta aumentar la potencia de salida de un <strong>l\u00e1ser para terapia<\/strong> to reach deep-seated pathology\u2014such as chronic tendinopathies, deep joint capsules, or canine hip dysplasia\u2014the superficial tissues absorb excessive energy. This leads to rapid heat accumulation, localized thermal discomfort, and even surface burns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El reto cl\u00ednico es claro: \u00bfc\u00f3mo podemos administrar una dosis terap\u00e9utica de fotones a un tejido diana situado entre 5 y 8 cent\u00edmetros por debajo de la piel sin causar da\u00f1o t\u00e9rmico en la superficie? La respuesta reside en la manipulaci\u00f3n estrat\u00e9gica de los principios f\u00edsicos, concretamente en la interacci\u00f3n de las longitudes de onda, las curvas de absorci\u00f3n y la modulaci\u00f3n de los pulsos.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>                  TYPICAL PHOTON ABSORPTION PROFILE\n                  \n      Melanin\/Water Peak                     Target Pathology (5-8cm)\n     &#091;Epidermal Barrier] ------------------&gt; &#091;Deep Tendon \/ Joint Capsule]\n              |                                         |\n      (Excessive Absorption)                    (Insufficient Photons)\n              |                                         |\n      Thermal Overheating                       Sub-therapeutic Dose\n<\/code><\/pre>\n\n\n\n<h2 class=\"wp-block-heading\">Desvinculaci\u00f3n de los aspectos f\u00edsicos: absorci\u00f3n de agua frente a uni\u00f3n selectiva a la hemoglobina<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para superar la barrera epid\u00e9rmica, debemos analizar c\u00f3mo interact\u00faan las diferentes longitudes de onda con los crom\u00f3foros biol\u00f3gicos. La ventana biol\u00f3gica para la fotobiomodulaci\u00f3n suele abarcar un rango de 600 nm a 1100 nm. Sin embargo, los l\u00e1seres m\u00e9dicos avanzados, como los dise\u00f1ados en el <em>LaserMedix 3000 U5<\/em> y <em>SurgMedix<\/em> plataformas, ampliar este rango hasta los 1470 nm para aprovechar v\u00edas fisiol\u00f3gicas espec\u00edficas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La curva de absorci\u00f3n a 1470 nm<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La longitud de onda de 1470 nm presenta un coeficiente de absorci\u00f3n en el agua aproximadamente 40 veces superior al de la longitud de onda de 980 nm. Seg\u00fan los estudios \u00f3pticos fundamentales publicados en la revista <em>Revista de \u00d3ptica Biom\u00e9dica<\/em>, when 1470 nm light interacts with tissue, it is rapidly absorbed by the water content in the extracellular matrix. This targeted absorption initiates a localized, controlled thermal effect that vasodilates microvessels. This vasodilation increases local blood flow and alters the tissue density, essentially creating an &#8220;optical gateway&#8221; that allows subsequent photons to penetrate deeper with less scattering.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"374\" src=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/07\/deep-tissue-laser-therapy1.jpg\" alt=\"\" class=\"wp-image-16598\" srcset=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/07\/deep-tissue-laser-therapy1.jpg 400w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/07\/deep-tissue-laser-therapy1-300x281.jpg 300w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/07\/deep-tissue-laser-therapy1-13x12.jpg 13w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">La interacci\u00f3n de la hemoglobina a 980 nm<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Por el contrario, la longitud de onda de 980 nm act\u00faa sobre la hemoglobina oxigenada y desoxigenada. El perfil de absorci\u00f3n a 980 nm est\u00e1 optimizado para estimular la enzima citocromo c oxidasa dentro de la cadena respiratoria mitocondrial. Esta estimulaci\u00f3n acelera la s\u00edntesis de trifosfato de adenosina (ATP), potencia la liberaci\u00f3n de \u00f3xido n\u00edtrico (NO) y modula las especies reactivas del ox\u00edgeno (ROS). Al combinar las longitudes de onda de 1470 nm y 980 nm, el profesional consigue un efecto terap\u00e9utico de doble acci\u00f3n: la longitud de onda de 1470 nm prepara el lecho vascular y alivia las terminaciones nerviosas locales, mientras que la de 980 nm impulsa la reparaci\u00f3n celular profunda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Gesti\u00f3n de la energ\u00eda t\u00e9rmica mediante el ciclo de trabajo por impulsos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Para aplicar estas longitudes de onda de forma segura a potencias m\u00e1ximas elevadas (hasta 30 W o 45 W), la emisi\u00f3n en onda continua (CW) suele resultar inadecuada para tejidos densos. Es aqu\u00ed donde el <strong>ciclo de trabajo del pulso<\/strong> se convierte en un factor cr\u00edtico.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By utilizing Superpulsed or Gated Pulsed modes (for example, a 50% duty cycle where the laser is active for 10 milliseconds and inactive for 10 milliseconds), the <a href=\"https:\/\/fotonmedix.com\/es\/overcoming-deep-tissue-hypoxia-without-thermal-tissue-damage.html\/\"  data-wpil-monitor-id=\"4833\">tissue is allowed a &#8220;thermal<\/a> relaxation time.&#8221; The equation governing this relationship is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">$$\\text{Tiempo de relajaci\u00f3n t\u00e9rmica } (\\tau) \\approx \\frac{d^2}{4\\alpha}$$<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00f3nde:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>$d$ es la profundidad de penetraci\u00f3n o la dimensi\u00f3n estructural.<\/li>\n\n\n\n<li>$\\alpha$ es la difusividad t\u00e9rmica del tejido.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Al hacer que el l\u00e1ser emita pulsos, permitimos que el calor generado en las capas superficiales se disipe hacia la circulaci\u00f3n sangu\u00ednea antes de que llegue el siguiente pulso de fotones. Esto permite que el <strong>dispositivo de terapia con l\u00e1ser fr\u00edo aprobado por la fda<\/strong> to deliver high peak powers to deep structures without exceeding the thermal pain threshold of the patient&#8217;s skin.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Registro de casos cl\u00ednicos: Protocolo de fotobiomodulaci\u00f3n de tejidos profundos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El siguiente conjunto de datos cl\u00ednicos representa un programa terap\u00e9utico estructurado dirigido a patolog\u00edas de los tejidos profundos, tanto en el \u00e1mbito de la medicina deportiva humana como en aplicaciones veterinarias (como las que se tratan con el <em>VetMedix<\/em> y <em>HorseVet<\/em> (serie).<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Perfil del paciente<\/strong><\/td><td><strong>Patolog\u00eda y grado<\/strong><\/td><td><strong>Mezcla de longitudes de onda primarias<\/strong><\/td><td><strong>Potencia de salida (W)<\/strong><\/td><td><strong>Modulaci\u00f3n y ciclo de trabajo<\/strong><\/td><td><strong>Densidad energ\u00e9tica objetivo (J\/cm\u00b2)<\/strong><\/td><td><strong>Total de julios por sesi\u00f3n<\/strong><\/td><td><strong>Resultados cl\u00ednicos (tras 6 sesiones)<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Hombre, 42 a\u00f1os, deportista<\/td><td>Tendinopat\u00eda cr\u00f3nica del tend\u00f3n de Aquiles (grado II)<\/td><td>60% 980 nm + 40% 1470 nm<\/td><td>15 W pico<\/td><td>Pulsos con puerta, 500 Hz, ciclo de trabajo 40%<\/td><td>12 $J\/cm^2$<\/td><td>3,600 J<\/td><td>La puntuaci\u00f3n del dolor (EVA) se redujo de 8\/10 a 2\/10; el grosor del tend\u00f3n disminuy\u00f3 en 1,8 mm seg\u00fan la ecograf\u00eda.<\/td><\/tr><tr><td>Mujer, 58 a\u00f1os, empleada de oficina<\/td><td>Capsulitis adhesiva (hombro congelado, fase 2)<\/td><td>50% 980 nm + 50% 1470 nm<\/td><td>20 W de potencia m\u00e1xima<\/td><td>Onda continua (CW) con barrido activo<\/td><td>15 $J\/cm^2$<\/td><td>4,500 J<\/td><td>El rango de movimiento de abducci\u00f3n activa aument\u00f3 en 45 grados; el dolor nocturno desapareci\u00f3.<\/td><\/tr><tr><td>Perro (Golden Retriever), 8 a\u00f1os<\/td><td>Artrosis bilateral de cadera (grado III)<\/td><td>70% 980 nm + 30% 1470 nm<\/td><td>12 W de potencia m\u00e1xima<\/td><td>Pulsos con puerta, 1000 Hz, ciclo de trabajo 50%<\/td><td>10 $J\/cm^2$<\/td><td>3.000 J por cadera<\/td><td>Mejora significativa en la extensi\u00f3n de las extremidades p\u00e9lvicas; se suspendi\u00f3 el tratamiento con AINE tras la cuarta sesi\u00f3n.<\/td><\/tr><tr><td>Caballo (pura sangre), 4 a\u00f1os<\/td><td>Tendinitis del flexor digital superficial (aguda)<\/td><td>80% 980 nm + 20% 915 nm\/1470 nm<\/td><td>30 W de potencia m\u00e1xima<\/td><td>Superpulsado, 2500 Hz, ciclo de trabajo 30%<\/td><td>18 $J\/cm^2$<\/td><td>8,000 J<\/td><td>Optimizaci\u00f3n de la alineaci\u00f3n de las fibras confirmada mediante ecograf\u00eda diagn\u00f3stica; sin picos de calor localizados.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Integraci\u00f3n pr\u00e1ctica: implantaci\u00f3n de la terapia con l\u00e1ser de alta potencia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para integrar con \u00e9xito un dispositivo de alta potencia <strong>m\u00e1quina de terapia l\u00e1ser<\/strong> into a busy clinical practice or veterinary hospital, operators must move away from a &#8220;one-size-fits-all&#8221; mentality. Different tissues require highly specific dosing strategies based on their physical composition and depth.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>                          TISSUE DEPTH &amp; DOSING PROTOCOL\n                          \n       Superficial Dermal Pain                Deep Muscle &amp; Joint Capsules\n     &#091;0 - 2 cm; e.g., Neuropathies]          &#091;5 - 8 cm; e.g., Hip Dysplasia]\n                 |                                         |\n     - Low Power (2W - 5W)                   - High Power (15W - 30W)\n     - Continuous Wave (CW)                  - Pulsed Mode (40-50% Duty Cycle)\n     - Focus on 650nm \/ 810nm                - Focus on 980nm \/ 1470nm\n<\/code><\/pre>\n\n\n\n<h3 class=\"wp-block-heading\">1. Dosificaci\u00f3n en tejido superficial frente a tejido profundo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Para las patolog\u00edas superficiales (de 0 a 2 cm de profundidad, como las neuropat\u00edas superficiales o las heridas abiertas), lo ideal es utilizar niveles de potencia m\u00e1s bajos (de 2 W a 5 W) combinados con una emisi\u00f3n de onda continua (CW). De este modo, la densidad de fotones se mantiene concentrada en la dermis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For deep pathologies (5 to 8 cm depth), power must be scaled to 15W\u201330W, utilizing a pulsed duty cycle (40% to 50%) and high-wavelength components (980nm and 1470nm) to drive the photons through the biological scatter zone.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Parto con asistencia frente a parto sin asistencia<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El uso de una pieza de mano de contacto con compresi\u00f3n manual resulta muy eficaz para las estructuras profundas. Al aplicar presi\u00f3n f\u00edsica con la pieza de mano del l\u00e1ser, se desplaza temporalmente el l\u00edquido intersticial y la sangre del tejido superficial. Esta reducci\u00f3n de la densidad local de crom\u00f3foros disminuye la absorci\u00f3n superficial, lo que permite que lleguen m\u00e1s fotones al tejido diana profundo. La aplicaci\u00f3n sin contacto debe reservarse para heridas abiertas, lesiones muy agudas o zonas hipersensibles en las que la presi\u00f3n mec\u00e1nica provoque dolor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Seguridad del paciente y protecci\u00f3n ocular<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En el caso de los l\u00e1seres terap\u00e9uticos de clase IV, la seguridad ocular es el control administrativo m\u00e1s importante. Todas las personas que se encuentren en la zona de riesgo nominal (NHZ) deben llevar gafas de seguridad espec\u00edficas para la longitud de onda correspondiente. La densidad \u00f3ptica (DO) de las gafas debe ser $\\text{DO} \\ge 5$ para los rangos espectrales espec\u00edficos del l\u00e1ser (que suelen abarcar 808 nm, 905 nm, 980 nm y 1470 nm).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Preguntas frecuentes de los responsables de compras B2B y de los responsables cl\u00ednicos<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">P1: \u00bfCu\u00e1l es la principal diferencia en cuanto al retorno de la inversi\u00f3n (ROI) entre la adquisici\u00f3n de un l\u00e1ser est\u00e1ndar de 10 W y la de un sistema de m\u00faltiples longitudes de onda de 30 W?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un sistema de menor potencia, de 10 W, requiere tiempos de tratamiento considerablemente m\u00e1s largos (a menudo entre 20 y 30 minutos por paciente) para alcanzar una dosis terap\u00e9utica ($J\/cm^2$) en los tejidos profundos. Un sistema de 30 W con m\u00faltiples longitudes de onda reduce los tiempos de tratamiento a entre 4 y 8 minutos por paciente. Esta alta eficiencia aumenta directamente el n\u00famero de pacientes atendidos, lo que permite a una cl\u00ednica con mucha actividad tratar entre 3 y 4 veces m\u00e1s pacientes al d\u00eda por sala de tratamiento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Furthermore, the addition of the 1470nm <a href=\"https:\/\/fotonmedix.com\/es\/optimizing-complex-tendon-bone-interface-repair-via-combined-wavelength-fluid-kinetics.html\/\"  data-wpil-monitor-id=\"4905\">wavelength provides immediate analgesic effects via<\/a> water-absorption-mediated nerve desensitization, leading to higher patient retention and referral rates.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Q2: How does the FDA clearance status of a &#8220;cold laser&#8221; apply to these high-power Class IV systems?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The term &#8220;cold laser&#8221; historically referred to low-level laser therapy (LLLT) devices operating below 500mW (Class IIIb). However, modern Class IV systems, such as an <strong>dispositivo de terapia con l\u00e1ser fr\u00edo aprobado por la fda<\/strong>, achieve a &#8220;cold&#8221; biological sensation on the skin surface by using advanced pulsing technologies and duty-cycle management.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Est\u00e1n autorizados por la FDA con el c\u00f3digo de producto NHN (dispositivos de luz para medicina f\u00edsica) para el alivio temporal de dolores musculares y articulares leves, espasmos musculares y el aumento temporal de la circulaci\u00f3n sangu\u00ednea local. Su uso cl\u00ednico cumple con la normativa, siempre que se respeten los protocolos de seguridad.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pregunta 3: \u00bfCu\u00e1les son los costes de mantenimiento continuado, la vida \u00fatil de los diodos y los requisitos de calibraci\u00f3n de estos sistemas?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos de diodos de arseniuro de galio y aluminio (GaAlAs) de alta calidad tienen una vida \u00fatil de m\u00e1s de 20 000 horas. En un entorno cl\u00ednico t\u00edpico, en el que el l\u00e1ser est\u00e1 en funcionamiento entre 2 y 3 horas al d\u00eda, los diodos funcionar\u00e1n de forma \u00f3ptima durante m\u00e1s de 15 a\u00f1os sin p\u00e9rdida de potencia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se recomienda realizar una calibraci\u00f3n anual para garantizar que la potencia de salida de la pieza de mano coincida con las lecturas de la interfaz de usuario. El mantenimiento es m\u00ednimo y consiste principalmente en la inspecci\u00f3n y limpieza de las puntas de fibra \u00f3ptica con alcohol isoprop\u00edlico para evitar que el polvo se adhiera a ellas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>High-Power Dual-Wavelength Photobiomodulation for Accelerated Deep Musculoskeletal Recovery Executive Summary: Dual-wavelength (1470nm + 980nm) emission optimizes the photon distribution profile. By utilizing a 50% duty cycle at 30W, the system achieves maximum deep-tissue ATP stimulation with zero thermal risks. The Deep Tissue Penetration Dilemma in Modern Physical Therapy Practitioners in orthopedic rehab and veterinary sports [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"slim_seo":{"title":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths - FotonMedix","description":"High-Power Dual-Wavelength Photobiomodulation for Accelerated Deep Musculoskeletal Recovery Executive Summary: Dual-wavelength (1470nm + 980nm) emission optimiz"},"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"","_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[19],"tags":[815,816,819],"class_list":["post-16597","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-laser-therapy-machine","tag-laser-therapy-device","tag-cold-laser-therapy"],"metadata":{"_edit_lock":["1784252936:1"],"_edit_last":["1"],"_aioseo_title":["Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths"],"_aioseo_description":["Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"catce":["sidebar-widgets4"],"views":["230"],"wpil_links_inbound_internal_count":["0"],"wpil_links_inbound_internal_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_links_outbound_internal_count":["2"],"wpil_links_outbound_internal_count_data":["eJzlU01v2zAM\/SuGBuymNk6aNlX+wr5uOxqMRMdEZcmw6HysyH8fZbvdgqGH7TAM2MkSRT7yPT6DWZpnMovtZ1Oujfraka8+Roe++kDhSZlyZZ6TeTDKy7Uip7Y5OZmVUUPvlZw2G6Ma5i6Z29s6cgwtOjrd2NjexgP28qWw1w6x00wpDaibcxdPBPpI3MSBNTfYt+Bfnh20sMebhtsR\/07gY+J8LOV83WIcwCgKjH0Ayd+ZcqrpxppfWH3J4QwkrJZSOBIq79ebBymTVCb2qLafJhA+d6h+xkvm3qjEwEOakkQZG6V74Om+npRKrxDJD\/vpIpXWk31524yYxBTDFMiTxn4PgWzFPdQ12ddC4cuxn\/NKo8DW1VXfR6NaZKgcMKgtmIV5vkhqppiqhLF6JXYZASHYJgPKJjPPUfmCUgHexyO6Aor37zbL5WI7L0fNA4Jz6KrdueqEF4Us+GIi46OFicy1KqLzYrbPsaHUYV\/ZHoFxkn4mJFPCwDGnvVgsh0UH+yT+GZ036nm3Wa3U\/NpGN3isroqWc6+x\/4mn+CU3+mOHl9l3b1m8Y2rpW7a4XDuPJy20XQx6FwPq0Zg1WNQ9dkC9PojvJXFHAZ0+wgE9hj03uvYDOS1Ukcmmv2v+u\/vl\/2r+tcD92ELR9fFADlNBbVZZTFqAKLvHRLbAukbLqZAV\/jt\/w+Ni\/ft\/w+U7uO\/1bQ=="],"wpil_links_outbound_external_count":["0"],"wpil_links_outbound_external_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_sync_report3":["1"],"wpil_sync_report2_time":["2026-09-16T07:54:54+00:00"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\" \/>\n\t\t<meta property=\"og:description\" content=\"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-07-31T11:30:02+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-07-31T11:30:02+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#blogposting\",\"name\":\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\",\"headline\":\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/deep-tissue-laser-therapy1.jpg\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html\\\/#articleImage\",\"width\":400,\"height\":374},\"datePublished\":\"2026-07-31T19:30:02+08:00\",\"dateModified\":\"2026-07-31T19:30:02+08:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#webpage\"},\"articleSection\":\"Industry News, Laser Therapy Machine, Laser Therapy Device, Cold Laser Therapy\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/es\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#listItem\",\"name\":\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#listItem\",\"position\":4,\"name\":\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html\",\"name\":\"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\",\"description\":\"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/author\\\/fengmaiadmin#author\"},\"datePublished\":\"2026-07-31T19:30:02+08:00\",\"dateModified\":\"2026-07-31T19:30:02+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/es\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Los profesionales sanitarios combaten el da\u00f1o t\u00e9rmico en los tejidos profundos mediante m\u00faltiples longitudes de onda","description":"Descubre c\u00f3mo los especialistas cl\u00ednicos combinan las longitudes de onda de 1470 nm y 980 nm para atravesar la barrera cut\u00e1nea y acelerar la recuperaci\u00f3n musculoesquel\u00e9tica profunda sin provocar quemaduras t\u00e9rmicas.","canonical_url":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#blogposting","name":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","headline":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","author":{"@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/es\/#person"},"image":{"@type":"ImageObject","url":"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/07\/deep-tissue-laser-therapy1.jpg","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html\/#articleImage","width":400,"height":374},"datePublished":"2026-07-31T19:30:02+08:00","dateModified":"2026-07-31T19:30:02+08:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#webpage"},"articleSection":"Industry News, Laser Therapy Machine, Laser Therapy Device, Cold Laser Therapy"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/es","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/es\/categoria\/noticias","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#listItem","name":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#listItem","position":4,"name":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author","url":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#webpage","url":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html","name":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","description":"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/fotonmedix.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/es\/author\/fengmaiadmin#author"},"datePublished":"2026-07-31T19:30:02+08:00","dateModified":"2026-07-31T19:30:02+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/es\/#website","url":"https:\/\/fotonmedix.com\/es\/","name":"FotonMedix","inLanguage":"es-ES","publisher":{"@id":"https:\/\/fotonmedix.com\/es\/#person"}}]},"og:locale":"es_ES","og:site_name":"FotonMedix |","og:type":"article","og:title":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","og:description":"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns.","og:url":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html","article:published_time":"2026-07-31T11:30:02+00:00","article:modified_time":"2026-07-31T11:30:02+00:00","twitter:card":"summary_large_image","twitter:title":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","twitter:description":"Discover how clinical specialists balance 1470nm and 980nm wavelengths to bypass the skin barrier and accelerate deep musculoskeletal recovery without thermal burns."},"aioseo_meta_data":{"post_id":"16597","title":"Los profesionales sanitarios combaten el da\u00f1o t\u00e9rmico en los tejidos profundos mediante m\u00faltiples longitudes de onda","description":"Descubre c\u00f3mo los especialistas cl\u00ednicos combinan las longitudes de onda de 1470 nm y 980 nm para atravesar la barrera cut\u00e1nea y acelerar la recuperaci\u00f3n musculoesquel\u00e9tica profunda sin provocar quemaduras t\u00e9rmicas.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-07-31 11:46:09","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-07-17 01:48:02","updated":"2026-07-31 11:57:06","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/es\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/es\/categoria\/noticias\" title=\"News\">News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news\" title=\"Industry News\">Industry News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tClinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/es"},{"label":"News","link":"https:\/\/fotonmedix.com\/es\/categoria\/noticias"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/es\/categoria\/noticias\/industry-news"},{"label":"Clinicians Combat Deep Tissue Thermal Damage via Multi Wavelengths","link":"https:\/\/fotonmedix.com\/es\/clinicians-combat-deep-tissue-thermal-damage-via-multi-wavelengths.html"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/16597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/comments?post=16597"}],"version-history":[{"count":4,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/16597\/revisions"}],"predecessor-version":[{"id":18760,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/posts\/16597\/revisions\/18760"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/media?parent=16597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/categories?post=16597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/es\/wp-json\/wp\/v2\/tags?post=16597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}