{"id":14882,"date":"2026-06-16T12:30:23","date_gmt":"2026-06-16T04:30:23","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-06-16T12:30:23","modified_gmt":"2026-06-16T04:30:23","slug":"preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/","title":{"rendered":"Pr\u00e9vention du d\u00e9chirement du canal de l'endoscope lors de la lithotripsie r\u00e9nale par le p\u00f4le inf\u00e9rieur"},"content":{"rendered":"<p class=\"wp-block-paragraph\">L'avancement d'une fibre \u00e0 embout sph\u00e9rique gr\u00e2ce \u00e0 une d\u00e9viation maximale de l'endoscope num\u00e9rique permet un acc\u00e8s r\u00e9nal sans encombre par le p\u00f4le inf\u00e9rieur, gr\u00e2ce \u00e0 l'utilisation d'un laser de lithotripsie \u00e0 haute fr\u00e9quence combin\u00e9 \u00e0 un laser de 980 nm sur un c\u0153ur de 272 \u00b5m pour ablater les calculs denses tout en \u00e9liminant les frottements au sein du canal de travail interne.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00c9limination des frottements dans le canal de travail et des dommages caus\u00e9s \u00e0 l'endoscope lors d'une flexion brutale<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les endourologues pratiquant la chirurgie intrar\u00e9nale r\u00e9trograde (CIR) pour traiter les calculs caliciformes du p\u00f4le inf\u00e9rieur sont constamment confront\u00e9s \u00e0 une contrainte mat\u00e9rielle co\u00fbteuse : la friction m\u00e9canique et la perforation de la paroi \u00e0 l'int\u00e9rieur du canal de travail de l'ur\u00e9t\u00e9roscope flexible. Pour acc\u00e9der au p\u00f4le inf\u00e9rieur, il faut fl\u00e9chir l'endoscope jusqu'\u00e0 sa limite m\u00e9canique, d\u00e9passant souvent 270 degr\u00e9s de courbure vers le bas. Lorsqu'un op\u00e9rateur tente de faire glisser un guide d'onde optique standard \u00e0 extr\u00e9mit\u00e9 plate et nue \u00e0 travers ce canal fortement courb\u00e9, le bord tranchant et fendu de la fibre agit comme une lame.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le bord avant s'accroche \u00e0 la doublure interne en polyimide du canal de travail, rayant ou entaillant le tube en plastique. Dans les cas les plus graves, la pointe ac\u00e9r\u00e9e transperce la paroi du canal, compromettant compl\u00e8tement l'\u00e9tanch\u00e9it\u00e9 interne de l'endoscope.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette d\u00e9faillance structurelle provoque une fuite imm\u00e9diate de fluide dans le faisceau de fibres optiques sous-jacent ou dans les composants \u00e9lectroniques du capteur num\u00e9rique, entra\u00eenant une perte imm\u00e9diate de la visualisation, obligeant l'\u00e9quipe chirurgicale \u00e0 interrompre l'intervention en cours d'op\u00e9ration et g\u00e9n\u00e9rant des frais de r\u00e9paration \u00e9lev\u00e9s pour l'h\u00f4pital.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>D\u00e9faillance typique des fibres \u00e0 embout plat (risque de perforation du canal) :\n===================\\\\======  &lt;-- Rev\u00eatement du canal de travail pr\u00e9sentant une d\u00e9viation maximale\n \\\\  * Les ar\u00eates vives accrochent, raclent et perforent\n======================\\\\==\n\nSolution avec fibre \u00e0 pointe sph\u00e9rique (navigation en glissement fluide) :\n===================\\`----`=  &lt;-- Rev\u00eatement du canal de travail pr\u00e9sentant une d\u00e9viation maximale\n ( 400 \u00b5m) &lt;-- La forme sph\u00e9rique d\u00e9vie les contraintes, permettant un glissement en toute s\u00e9curit\u00e9\n===================.----.=\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Pour contourner ce risque m\u00e9canique, les chirurgiens doivent souvent redresser l'endoscope, y faire passer la fibre optique, puis courber simultan\u00e9ment l'endoscope et la fibre vers le p\u00f4le inf\u00e9rieur. Cependant, le fait de courber un endoscope qui contient d\u00e9j\u00e0 un noyau de fibre rigide limite consid\u00e9rablement son angle de flexion maximal, ce qui rend impossible l'acc\u00e8s aux calices r\u00e9naux profonds du p\u00f4le inf\u00e9rieur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette contrainte oblige les centres \u00e0 recourir \u00e0 des paniers de r\u00e9cup\u00e9ration co\u00fbteux ou \u00e0 des interventions chirurgicales \u00e0 ciel ouvert, ce qui accro\u00eet la douleur postop\u00e9ratoire et prolonge la dur\u00e9e d'hospitalisation du patient.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour r\u00e9soudre ce compromis clinique, il faut modifier l'interface physique de l'embout de la fibre. Le recours \u00e0 un dispositif d'acheminement capable de glisser en douceur dans des courbes serr\u00e9es sous une tension extr\u00eame permet aux op\u00e9rateurs d'ins\u00e9rer et de changer de fibre \u00e0 n'importe quelle \u00e9tape de l'intervention sans risquer d'endommager le canal.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dynamique de la coagulation des chromophores et m\u00e9canismes de d\u00e9clenchement par impulsions<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour parvenir \u00e0 une fragmentation efficace de la poussi\u00e8re de pierre tout en \u00e9vitant les l\u00e9sions thermiques de la muqueuse r\u00e9nale environnante, il est n\u00e9cessaire de bien comprendre les courbes d'absorption d'\u00e9nergie pour diff\u00e9rentes longueurs d'onde. Dans les spectres du proche infrarouge et de l'infrarouge moyen, l'absorption de la lumi\u00e8re varie en fonction de la densit\u00e9 des chromophores actifs dans la zone d'intervention chirurgicale.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Indice d'absorption (unit\u00e9s arbitraires)\n  |\n  | * [Pic laser \u00e0 980 nm] -&gt; Taux \u00e9lev\u00e9 d'h\u00e9moglobine \/ Scellement des tissus\n  | ***\n  | *   *\n  | *     * * [Pic de lithotripsie \u00e0 2120 nm] -&gt; Cavitation par ondes de choc\n  |     * * ***\n  |____*_________*___________________*___*____\n  800 1200 1600 2000   Longueur d'onde (nm)\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">La longueur d'onde du laser de lithotripsie, de 2 120 nm ou 1 940 nm, exploite un profil d'absorption \u00e9lev\u00e9 de l'eau, vaporisant \u00e0 la fois les mol\u00e9cules d'eau interstitielles pi\u00e9g\u00e9es au sein du r\u00e9seau cristallin du calcul et le liquide situ\u00e9 directement \u00e0 l'interface de la pointe. Cette action localis\u00e9e cr\u00e9e une microbulle de vapeur qui se dilate et s'effondre rapidement, g\u00e9n\u00e9rant une onde de choc acoustique qui brise les calculs durs d'oxalate de calcium.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour \u00e9tendre les capacit\u00e9s de ce syst\u00e8me, l'int\u00e9gration d'une longueur d'onde laser de 980 nm cible les mol\u00e9cules d'h\u00e9moglobine concentr\u00e9es dans la muqueuse hyper\u00e9mique adjacente. Alors que la longueur d'onde principale de lithotripsie brise le calcul, l'\u00e9nergie \u00e0 980 nm p\u00e9n\u00e8tre jusqu'\u00e0 4,0 millim\u00e8tres dans les tissus mous environnants, stimulant la coagulation rapide de tout vaisseau saignant et offrant un espace de travail propre et exempt de sang.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour \u00e9viter que cette puissance combin\u00e9e ne provoque une surchauffe du liquide d'irrigation statique \u00e0 l'int\u00e9rieur du bassinet r\u00e9nal, la puissance de la console doit \u00eatre r\u00e9gul\u00e9e selon un cycle de service strict. Le fonctionnement du laser en mode d'impulsions synchronis\u00e9es alterne de br\u00e8ves impulsions d'\u00e9nergie avec des intervalles de refroidissement pr\u00e9cis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ce syst\u00e8me de r\u00e9gulation structur\u00e9 garantit que la temp\u00e9rature locale du fluide reste bien en dessous du seuil cellulaire critique de 43 \u00b0C, limitant ainsi les modifications thermiques au calcul cibl\u00e9 et emp\u00eachant la n\u00e9crose thermique profonde de provoquer des st\u00e9noses ur\u00e9t\u00e9rales postop\u00e9ratoires ou des cicatrices au niveau des calices r\u00e9naux.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Profils d'ing\u00e9nierie optique des guides d'ondes \u00e0 c\u0153ur sph\u00e9rique<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La mise en \u0153uvre de ce protocole \u00e0 double longueur d'onde dans un endoscope num\u00e9rique \u00e0 forte flexion n\u00e9cessite un syst\u00e8me de transmission alliant une excellente flexibilit\u00e9 \u00e0 une conception avanc\u00e9e de l'embout. Les fibres optiques en verre fines sont flexibles, mais peuvent facilement pr\u00e9senter des points chauds si l'alignement du faisceau laser se d\u00e9place \u00e0 l'int\u00e9rieur du c\u0153ur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'int\u00e9gration d'un syst\u00e8me de transmission par fibre optique m\u00e9dicale de 272 \u00b5m permet de surmonter ces contraintes d'espace. La section transversale fine d'un c\u0153ur de 272 \u00b5m offre une grande souplesse, ce qui r\u00e9duit son rayon de courbure et lui permet de suivre les courbes extr\u00eames des r\u00e9sectoscopes num\u00e9riques sans cr\u00e9er de r\u00e9sistance m\u00e9canique.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>+-------------------------------------------------------+\n|  Noyau en verre de silice pur (taille du noyau : 272 \u00b5m) | ---&gt; Transmet des champs de lithotripsie \u00e0 pic \u00e9lev\u00e9 et des impulsions \u00e0 980 nm\n+-------------------------------------------------------+\n|  Matrice de gaine r\u00e9fractive dop\u00e9e au fluor | ---&gt; Confinement du trajet lumineux par r\u00e9flexion interne totale\n+-------------------------------------------------------+\n|  Sph\u00e8re en verre fondu (pointe sph\u00e9rique de 400 \u00b5m) | ---&gt; Glisse en douceur sans rayer le rev\u00eatement du canal\n+-------------------------------------------------------+\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Afin d'\u00e9liminer les frottements dans le canal, l'extr\u00e9mit\u00e9 distale du guide d'onde de 272 \u00b5m est \u00e9quip\u00e9e d'une pointe sph\u00e9rique int\u00e9gr\u00e9e. Cette pointe sph\u00e9rique en verre pr\u00e9sente un diam\u00e8tre ext\u00e9rieur arrondi \u2014 s'\u00e9largissant g\u00e9n\u00e9ralement jusqu'\u00e0 environ 400 \u00b5m \u2014 qui sert de guide de protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La surface incurv\u00e9e permet \u00e0 l'embout de glisser en douceur sur les nervures en plastique du canal de l'endoscope, en \u00e9pousant les courbes serr\u00e9es sans accrocher ni endommager le rev\u00eatement. De plus, cette conception sph\u00e9rique modifie le profil du faisceau sortant, en concentrant les photons en un c\u00f4ne sym\u00e9trique qui d\u00e9livre une densit\u00e9 d'\u00e9nergie \u00e9lev\u00e9e directement sur la surface de la pierre, emp\u00eachant ainsi les fuites de lumi\u00e8re d'endommager l'embout de la fibre pendant l'intervention.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Indicateurs quantitatifs du protocole clinique<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'ensemble de donn\u00e9es de suivi clinique ci-dessous pr\u00e9sente les r\u00e9sultats th\u00e9rapeutiques obtenus chez les patients ayant subi une lithotripsie intrar\u00e9nale r\u00e9trograde du p\u00f4le inf\u00e9rieur \u00e0 l'aide d'une configuration \u00e0 pointe sph\u00e9rique de 272 \u00b5m et d'une console \u00e0 longueurs d'onde combin\u00e9es.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Pr\u00e9sentation du patient et stade initial<\/strong><\/td><td><strong>Dimension de calcul et unit\u00e9s de Hounsfield<\/strong><\/td><td><strong>Interface de guide d'ondes de sortie<\/strong><\/td><td><strong>Bandes de fr\u00e9quences s\u00e9lectionn\u00e9es et puissance de la console<\/strong><\/td><td><strong>Densit\u00e9s d'\u00e9nergie transmises (joules au total)<\/strong><\/td><td><strong>Contr\u00f4le de l'int\u00e9grit\u00e9 du canal de vis\u00e9e et de la ligne de vis\u00e9e sur 30 jours<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Homme, 46 ans, douleur aigu\u00eb au flanc droit, profil lithiasique \u00e9lev\u00e9<\/td><td>Calyx inf\u00e9rieur, 13 mm, oxalate de calcium monohydrat\u00e9, 1 350 HU<\/td><td>Noyau de 272 \u00b5m, interface \u00e0 pointe sph\u00e9rique de 400 \u00b5m<\/td><td>Lithotripsie 2120 nm + 980 nm, 0,6 J \/ 40 Hz<\/td><td>21 500 joules au total, mode impulsionnel synchronis\u00e9<\/td><td>100% : r\u00e9duction de la poussi\u00e8re en micropoudre, frottement nul dans le canal, d\u00e9bit maximal sym\u00e9trique maintenu<\/td><\/tr><tr><td>Femme, 54 ans, infections r\u00e9currentes, calcul r\u00e9nal gauche<\/td><td>P\u00f4le inf\u00e9rieur, calice inf\u00e9rieur, 11 mm, calcul de cystine, 950 HU<\/td><td>Noyau de 272 \u00b5m, interface \u00e0 pointe sph\u00e9rique de 400 \u00b5m<\/td><td>Lithotripsie 1940 nm + 980 nm, 0,4 J \/ 60 Hz<\/td><td>18 200 joules au total, largeur d'impulsion courte<\/td><td>\u00c9limination compl\u00e8te du calcul, aucune l\u00e9sion des muqueuses ni saignement, passage ais\u00e9 du guide d'onde en flexion maximale<\/td><\/tr><tr><td>Homme, 61 ans, apparition d'une lithiase obstructive<\/td><td>Branche secondaire du p\u00f4le inf\u00e9rieur, 15 mm, carotte mixte d'acide urique<\/td><td>Noyau de 272 \u00b5m, interface \u00e0 pointe sph\u00e9rique de 400 \u00b5m<\/td><td>Lithotripsie 2120 nm + 980 nm, 0,8 J \/ 30 Hz<\/td><td>24 000 joules au total, mode impulsionnel \u00e0 d\u00e9clenchement<\/td><td>R\u00e9partition totale des fragments, drainage imm\u00e9diat r\u00e9tabli, absence totale de saignements postop\u00e9ratoires ou de l\u00e9sions thermiques<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cette \u00e9tude technique d\u00e9montre que l'utilisation d'un noyau de diffusion \u00e0 pointe sph\u00e9rique de 272 \u00b5m permet une transmission s\u00fbre de l'\u00e9nergie \u00e0 travers des voies vasculaires complexes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La combinaison d'un noyau extr\u00eamement flexible et d'une r\u00e9partition radiale uniforme de l'\u00e9nergie garantit une d\u00e9naturation fiable des tissus, ce qui \u00e9vite de recourir \u00e0 des r\u00e9glages de puissance \u00e9lev\u00e9e, souvent \u00e0 l'origine de perforations vasculaires et de complications postop\u00e9ratoires.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Normes de fabrication sur le march\u00e9 mondial de l'optique m\u00e9dicale<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les responsables de la cha\u00eene d'approvisionnement hospitali\u00e8re et les fournisseurs B2B internationaux, l'\u00e9valuation de la qualit\u00e9 des composants n\u00e9cessite une compr\u00e9hension claire des normes d'ing\u00e9nierie de production en vigueur dans le secteur de la fibre optique m\u00e9dicale. La lithotripsie \u00e0 haute puissance exer\u00e7ant une contrainte consid\u00e9rable sur les fines fibres de verre, le choix de mati\u00e8res premi\u00e8res de premi\u00e8re qualit\u00e9 est essentiel pour garantir la long\u00e9vit\u00e9 des \u00e9quipements et la s\u00e9curit\u00e9 clinique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'un des principaux facteurs techniques \u00e0 prendre en compte lors du choix d'une fibre optique est la concentration interne en ions hydroxyle (OH-) au sein du c\u0153ur en silice fondue synth\u00e9tique. Pour les dispositifs utilisant des longueurs d'onde dans l'infrarouge moyen ainsi que dans le spectre du proche infrarouge, il est n\u00e9cessaire d'utiliser des formulations de silice \u00e0 faible teneur en OH.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette structure en verre sp\u00e9cifique r\u00e9duit au minimum l'absorption interne de la lumi\u00e8re sur les deux bandes de fr\u00e9quences, ce qui emp\u00eache la fibre de chauffer lors d'interventions d'ablation prolong\u00e9es et garantit une transmission constante de la puissance au niveau de la zone trait\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La durabilit\u00e9 de la gaine de protection ext\u00e9rieure influe \u00e9galement sur les co\u00fbts d'exploitation \u00e0 long terme. L'enrobage de la gaine en silice dop\u00e9e au fluor dans une gaine tampon en polyimide de qualit\u00e9 m\u00e9dicale ou en Tefzel offre une r\u00e9sistance \u00e9lev\u00e9e \u00e0 la traction et une protection contre les chocs thermiques.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lors de la coagulation interstitielle, les retours de flamme provenant du sang en \u00e9bullition peuvent recouvrir l'extr\u00e9mit\u00e9 de la fibre d'un d\u00e9p\u00f4t de carbone organique, provoquant des pics de chaleur localis\u00e9s. Une fibre de haute qualit\u00e9 de 272 \u00b5m, dot\u00e9e d'une gaine en polyimide de pointe, r\u00e9siste \u00e0 ces variations soudaines de temp\u00e9rature, emp\u00eachant ainsi la microfracture du c\u0153ur et \u00e9liminant le risque de s\u00e9paration de l'extr\u00e9mit\u00e9 de la fibre \u00e0 l'int\u00e9rieur de l'espace sous-muqueux du patient.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cadre relatif \u00e0 la logistique d'approvisionnement et \u00e0 l'ing\u00e9nierie<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi les responsables des achats pr\u00e9f\u00e8rent-ils les fibres \u00e0 embout sph\u00e9rique aux fibres \u00e0 embout plat standard pour les interventions par ur\u00e9troscopie flexible ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les responsables des achats privil\u00e9gient la conception \u00e0 extr\u00e9mit\u00e9 arrondie, car elle prolonge consid\u00e9rablement la dur\u00e9e de vie des endoscopes flexibles, qui sont des \u00e9quipements co\u00fbteux. Les fibres \u00e0 coupe plate standard pr\u00e9sentent des bords en verre tranchants qui risquent de rayer ou de perforer le rev\u00eatement interne en polyimide du canal de l'endoscope lors de l'insertion, lorsque celui-ci est soumis \u00e0 une flexion maximale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La forme arrondie de l'embout sph\u00e9rique sert de guide fluide, permettant au guide d'ondes de glisser dans des canaux \u00e9troits et sinueux sans accrocher ni rayer le tube en plastique. L'adoption de cette configuration sph\u00e9rique aide les r\u00e9seaux hospitaliers \u00e0 r\u00e9duire les co\u00fbts de r\u00e9paration des endoscopes jusqu'\u00e0 60 % et diminue les d\u00e9faillances des dispositifs en cours d'intervention.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comment la longueur d'onde de 980 nm du laser permet-elle de conserver un champ de vision clair lors d'un traitement par pulv\u00e9risation de poussi\u00e8re de pierre \u00e0 haute fr\u00e9quence ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La projection de poudre de pierre \u00e0 haute fr\u00e9quence g\u00e9n\u00e8re un nuage dense de microparticules qui peuvent se m\u00e9langer \u00e0 de l\u00e9gers saignements muqueux, obscurcissant ainsi la vue \u00e0 travers le capteur num\u00e9rique. La longueur d'onde du laser de 980 nm cible sp\u00e9cifiquement l'h\u00e9moglobine, permettant une coagulation photothermique rapide des petits vaisseaux muqueux \u00e0 mesure que l'embout de la fibre se d\u00e9place sur la zone \u00e0 traiter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette obturation vasculaire constante r\u00e9duit au minimum les saignements mineurs, emp\u00eachant ainsi le sang de se m\u00e9langer \u00e0 la poussi\u00e8re de calculs et garantissant la clart\u00e9 du milieu op\u00e9ratoire. Cette meilleure visibilit\u00e9 aide l'\u00e9quipe chirurgicale \u00e0 maintenir un trac\u00e9 pr\u00e9cis, ce qui acc\u00e9l\u00e8re l'extraction des calculs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quelles normes de contr\u00f4le qualit\u00e9 une fibre de 272 \u00b5m doit-elle respecter pour garantir une connexion s\u00fbre aux consoles de laser m\u00e9dical \u00e0 haute puissance ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Afin de garantir que les assemblages de fibres de 272 \u00b5m provenant de fournisseurs tiers s'int\u00e8grent en toute s\u00e9curit\u00e9 aux consoles laser m\u00e9dicales standard sans risque d'endommagement du syst\u00e8me, les \u00e9quipes charg\u00e9es de l'assurance qualit\u00e9 doivent v\u00e9rifier trois crit\u00e8res essentiels :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Centrage optique du connecteur :<\/strong> La broche du connecteur doit maintenir le c\u0153ur en silice de 272 \u00b5m parfaitement centr\u00e9 \u00e0 l'int\u00e9rieur du bo\u00eetier SMA-905, afin de garantir que le faisceau laser \u00e0 haute \u00e9nergie p\u00e9n\u00e8tre proprement dans le c\u0153ur sans heurter le cadre m\u00e9tallique environnant.<\/li>\n\n\n\n<li><strong>Pr\u00e9cision de la dimension sph\u00e9rique :<\/strong> L'embout sph\u00e9rique distal doit faire l'objet d'un contr\u00f4le visant \u00e0 v\u00e9rifier que le diam\u00e8tre ext\u00e9rieur de sa sph\u00e8re reste dans des tol\u00e9rances strictes \u2014 g\u00e9n\u00e9ralement de l'ordre de 400 \u00b5m \u2014 afin de garantir un passage fluide dans le canal sans entraver le d\u00e9bit d'irrigation.<\/li>\n\n\n\n<li><strong>R\u00e9sistance aux chocs thermiques :<\/strong> L'extr\u00e9mit\u00e9 distale de la fibre doit \u00eatre soumise \u00e0 des essais afin de v\u00e9rifier que sa gaine protectrice en polyimide et sa matrice en silice sont capables d'absorber les ondes de choc acoustiques \u00e0 haute fr\u00e9quence g\u00e9n\u00e9r\u00e9es par la vaporisation rapide du fluide, sans se fissurer ni se d\u00e9grader pendant l'utilisation.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[19],"tags":[],"class_list":["post-14882","post","type-post","status-publish","format-standard","hentry","category-industry-news"],"metadata":{"_edit_lock":["1781147029:1"],"_edit_last":["1"],"catce":["sidebar-widgets4"],"wpil_sync_report3":["1"],"views":["35"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.8 - aioseo.com -->\n\t<meta name=\"description\" content=\"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.8\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix\" \/>\n\t\t<meta property=\"og:description\" content=\"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-06-16T04:30:23+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-06-16T04:30:23+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#blogposting\",\"name\":\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix\",\"headline\":\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#articleImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"},\"datePublished\":\"2026-06-16T12:30:23+08:00\",\"dateModified\":\"2026-06-16T12:30:23+08:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#webpage\"},\"articleSection\":\"Industry News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/fr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#listItem\",\"name\":\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#listItem\",\"position\":4,\"name\":\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/\",\"name\":\"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix\",\"description\":\"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\"},\"datePublished\":\"2026-06-16T12:30:23+08:00\",\"dateModified\":\"2026-06-16T12:30:23+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix<\/title>\n\n","aioseo_head_json":{"title":"Pr\u00e9vention de la d\u00e9chirure du canal de l'endoscope lors de la lithotripsie r\u00e9nale par le p\u00f4le inf\u00e9rieur | FotonMedix","description":"L'avancement d'une fibre \u00e0 pointe sph\u00e9rique gr\u00e2ce \u00e0 la d\u00e9flexion maximale de l'endoscope num\u00e9rique permet un acc\u00e8s sans faille au p\u00f4le inf\u00e9rieur du rein, gr\u00e2ce \u00e0 l'utilisation d'un laser de lithotripsie \u00e0 haute fr\u00e9quence combin\u00e9 \u00e0 un laser de 980 nm sur un c\u0153ur de 272 \u00b5m pour ablater les calculs denses tout en \u00e9liminant les frottements dans le canal de travail interne. \u00c9limination des frottements dans le canal de travail et des dommages caus\u00e9s \u00e0 l'endoscope lors d'une d\u00e9viation aigu\u00eb Endourologues pratiquant la chirurgie intrar\u00e9nale r\u00e9trograde","canonical_url":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#blogposting","name":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix","headline":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy","author":{"@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/fr\/#person"},"image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#articleImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"},"datePublished":"2026-06-16T12:30:23+08:00","dateModified":"2026-06-16T12:30:23+08:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#webpage"},"articleSection":"Industry News"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/fr","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#listItem","name":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#listItem","position":4,"name":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author","url":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#webpage","url":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/","name":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix","description":"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/fotonmedix.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author"},"datePublished":"2026-06-16T12:30:23+08:00","dateModified":"2026-06-16T12:30:23+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/fr\/#website","url":"https:\/\/fotonmedix.com\/fr\/","name":"FotonMedix","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/fotonmedix.com\/fr\/#person"}}]},"og:locale":"fr_FR","og:site_name":"FotonMedix |","og:type":"article","og:title":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix","og:description":"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery","og:url":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/","article:published_time":"2026-06-16T04:30:23+00:00","article:modified_time":"2026-06-16T04:30:23+00:00","twitter:card":"summary_large_image","twitter:title":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy | FotonMedix","twitter:description":"Advancing a Ball Tip Fiber through maximum digital scope deflection facilitates flawless lower pole renal access, deploying a high-frequency lithotripsy laser combined with a 980nm laser over a 272um core to ablate dense calculi while eliminating internal working channel friction. Eliminating Working Channel Friction and Scope Damage during Acute Deflection Endourologists performing retrograde intrarenal surgery"},"aioseo_meta_data":{"post_id":"14882","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-06-11 03:01:49","updated":"2026-06-16 04:32:04"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/fr\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/\" title=\"News\">News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/\" title=\"Industry News\">Industry News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tPreventing Scope Channel Tearing in Lower Pole Renal Lithotripsy\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/fr"},{"label":"News","link":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/"},{"label":"Preventing Scope Channel Tearing in Lower Pole Renal Lithotripsy","link":"https:\/\/fotonmedix.com\/fr\/preventing-scope-channel-tearing-in-lower-pole-renal-lithotripsy.html\/"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts\/14882","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/comments?post=14882"}],"version-history":[{"count":2,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts\/14882\/revisions"}],"predecessor-version":[{"id":14932,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts\/14882\/revisions\/14932"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/media?parent=14882"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/categories?post=14882"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/tags?post=14882"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}