{"id":15861,"date":"2026-07-03T16:00:54","date_gmt":"2026-07-03T08:00:54","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-07-03T16:00:54","modified_gmt":"2026-07-03T08:00:54","slug":"volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/","title":{"rendered":"Le contr\u00f4le volum\u00e9trique de la vaporisation permet d'\u00e9viter les risques d'h\u00e9morragie lors d'une n\u00e9phrectomie partielle endoscopique"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Les chirurgiens urologues pratiquant des n\u00e9phrectomies partielles par laparoscopie ou endoscopie sont r\u00e9guli\u00e8rement confront\u00e9s \u00e0 un grave dilemme technique lors de la vaporisation d\u2019un parenchyme hypervasculaire : d\u2019un c\u00f4t\u00e9, la n\u00e9cessit\u00e9 absolue d\u2019assurer une h\u00e9mostase microvasculaire profonde ; de l\u2019autre, l\u2019imp\u00e9ratif crucial de r\u00e9duire au minimum la marge n\u00e9crotique lat\u00e9rale afin de pr\u00e9server les n\u00e9phrons fonctionnels. Les boucles \u00e9lectrochirurgicales monopolaires standard g\u00e9n\u00e8rent des courants \u00e0 haute tension qui traversent sans distinction les tissus parenchymateux adjacents, provoquant une n\u00e9crose cellulaire profonde et impr\u00e9visible ainsi qu\u2019une thrombose thermique au sein des canaux collecteurs sains. L\u2019utilisation d\u2019un laser chirurgical \u00e0 double diode optimis\u00e9 r\u00e9sout ce probl\u00e8me de pr\u00e9cision, en concentrant une \u00e9nergie de vaporisation de pointe \u00e9lev\u00e9e sur la ligne d\u2019incision tout en d\u00e9clenchant simultan\u00e9ment une occlusion capillaire cibl\u00e9e le long de la bordure parenchymateuse, sans \u00e9tendre la zone isch\u00e9mique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'administration coaxiale simultan\u00e9e \u00e0 1 470 nm et 980 nm permet une vaporisation parenchymateuse instantan\u00e9e et une occlusion microvasculaire. Les cycles de d\u00e9clenchement de l'ordre de la microseconde limitent la n\u00e9crose des tissus collat\u00e9raux \u00e0 moins de 0,2 millim\u00e8tre afin de pr\u00e9server les n\u00e9phrons fonctionnels. Les fibres \u00e0 c\u0153ur de quartz haut de gamme de grande puret\u00e9 garantissent une efficacit\u00e9 de transmission optimale pendant les protocoles perop\u00e9ratoires prolong\u00e9s.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Absorption d'\u00e9nergie quantique et limitation des bords n\u00e9crotiques dans le parenchyme vasculaire<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour r\u00e9aliser une incision non traumatique \u00e0 travers un parenchyme r\u00e9nal fortement vascularis\u00e9, il est n\u00e9cessaire de modifier les coefficients d\u2019absorption de l\u2019eau et de l\u2019h\u00e9moglobine par les tissus. La courbe d\u2019att\u00e9nuation spatiale de l\u2019\u00e9nergie optique au sein d\u2019organes denses est r\u00e9gie par les coefficients d\u2019extinction sp\u00e9cifiques des chromophores qui les composent. Les syst\u00e8mes traditionnels fonctionnant exclusivement \u00e0 1 064 nm ou 2 100 nm pr\u00e9sentent des profils de coupe lents ou un comportement de diffusion profonde, ce qui n\u00e9cessite des puissances de sortie \u00e9lev\u00e9es entra\u00eenant une carbonisation importante des tissus et des saignements retard\u00e9s postop\u00e9ratoires.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Face de la couche parenchymateuse -&gt; 1 470 nm (vaporisation de l'eau cellulaire) + 980 nm (coagulation du plasma)\n |\nLigne d'incision micro-focale -&gt; Ablation volum\u00e9trique limit\u00e9e \u00e0 une trajectoire cibl\u00e9e de 0,3 mm\n |\nMarge n\u00e9phronique collat\u00e9rale -&gt; La relaxation thermique en microsecondes emp\u00eache la n\u00e9crose profonde\n |\nCanaux collecteurs profonds -&gt; Aucune fuite d'\u00e9nergie, protection structurelle totale\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Pour limiter la n\u00e9crose des tissus environnants \u00e0 moins de 0,2 millim\u00e8tre lors de la r\u00e9section d\u2019organes denses et fortement vascularis\u00e9s, les \u00e9quipements chirurgicaux laser de pointe s\u2019appuient sur une approche synchronis\u00e9e \u00e0 double longueur d\u2019onde. La longueur d\u2019onde de 1 470 nm cible les mol\u00e9cules d\u2019eau pr\u00e9sentes dans la matrice cellulaire parenchymateuse, provoquant une vaporisation cellulaire rapide lorsque l\u2019eau atteint son point d\u2019\u00e9bullition, ce qui permet d\u2019obtenir un bord de coupe net sans frottement m\u00e9canique sur les tissus. Parall\u00e8lement, la composante int\u00e9gr\u00e9e \u00e0 980 nm cible l\u2019h\u00e9moglobine pr\u00e9sente dans les r\u00e9seaux capillaires locaux, scellant instantan\u00e9ment les microvaisseaux le long de la ligne d\u2019incision afin de maintenir un champ op\u00e9ratoire sec et d\u00e9gag\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour contr\u00f4ler avec pr\u00e9cision cette d\u00e9livrance d\u2019\u00e9nergie, il est n\u00e9cessaire de moduler le profil d\u2019\u00e9mission optique au moyen d\u2019un cycle de service fractionn\u00e9. La d\u00e9livrance d\u2019une \u00e9nergie de cr\u00eate \u00e9lev\u00e9e sous forme de salves de l\u2019ordre de la microseconde offre aux tissus sains environnants des phases de relaxation thermique essentielles. Au cours de ces brefs intervalles \u201c d\u2019arr\u00eat \u201d, la circulation capillaire locale dissipe l\u2019accumulation de chaleur en surface, emp\u00eachant ainsi la propagation de l\u2019\u00e9nergie thermique vers les n\u00e9phrons sains et minimisant le gonflement localis\u00e9 ainsi que la desquamation tissulaire diff\u00e9r\u00e9e.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Analyse du co\u00fbt total de possession et des performances op\u00e9rationnelles des blocs op\u00e9ratoires d'urologie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les sp\u00e9cialistes de l'int\u00e9gration des r\u00e9seaux de soins de sant\u00e9 et les responsables des achats hospitaliers, l'analyse du prix d'un laser chirurgical n\u00e9cessite de ne pas se limiter au devis d'investissement initial, mais d'\u00e9valuer \u00e9galement les co\u00fbts d'exploitation \u00e0 long terme et la dur\u00e9e de vie des composants dans le cadre d'un calendrier de bloc op\u00e9ratoire tr\u00e8s charg\u00e9. Les plateformes d'entr\u00e9e de gamme semblent souvent attractives sur le papier, mais finissent par co\u00fbter plus cher \u00e0 long terme en raison des pannes fr\u00e9quentes des diodes et du co\u00fbt \u00e9lev\u00e9 des c\u00e2bles \u00e0 fibre optique propri\u00e9taires.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Indicateur clinique d'approvisionnement<\/strong><\/td><td><strong>Normes professionnelles en mati\u00e8re de mat\u00e9riel informatique<\/strong><\/td><td><strong>Impact op\u00e9rationnel direct sur la clinique<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Conception d'un circuit d'isolation \u00e0 diodes<\/strong><\/td><td>Architecture multi-r\u00e9seaux ind\u00e9pendante avec des pilotes distincts<\/td><td>\u00c9limine tout temps d'arr\u00eat du syst\u00e8me en cas de probl\u00e8me sur un seul canal de diode<\/td><\/tr><tr><td><strong>Stabilisation thermique<\/strong><\/td><td>Refroidissement thermo\u00e9lectrique \u00e0 l'\u00e9tat solide (TEC) sur des blocs de cuivre massifs<\/td><td>Emp\u00eache toute d\u00e9rive de puissance thermique, garantissant une sortie stable du 100% tout au long de la journ\u00e9e<\/td><\/tr><tr><td><strong>Syst\u00e8me de transmission optique<\/strong><\/td><td>C\u00e2bles \u00e0 fibres optiques en quartz, blind\u00e9s d'acier et d\u00e9montables<\/td><td>R\u00e9duit les co\u00fbts d'entretien \u00e0 long terme ; permet un remplacement rapide sans avoir \u00e0 faire appel \u00e0 l'usine<\/td><\/tr><tr><td><strong>Classification des r\u00e9sultats<\/strong><\/td><td>Respect total des exigences en mati\u00e8re de s\u00e9curit\u00e9 chirurgicale de classe IV<\/td><td>Fournit la densit\u00e9 de puissance brute n\u00e9cessaire pour des traitements rapides des grands groupes musculaires<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Les \u00e9tablissements cliniques qui optent pour des configurations modulaires d'\u00e9quipements chirurgicaux au laser peuvent r\u00e9duire consid\u00e9rablement les d\u00e9lais d'intervention sur site. Lorsqu'un appareil \u00e0 carte unique int\u00e9gr\u00e9e tombe en panne, la console enti\u00e8re doit \u00eatre emball\u00e9e et renvoy\u00e9e \u00e0 l'usine, ce qui entra\u00eene plusieurs semaines de perte de chiffre d'affaires et perturbe les rendez-vous des patients. Les plateformes mat\u00e9rielles modulaires propos\u00e9es par fotonmedix.com permettent aux techniciens locaux d'effectuer rapidement des remplacements de composants directement sur place, ce qui garantit le bon d\u00e9roulement de votre activit\u00e9 quotidienne et pr\u00e9serve votre flux de travail clinique.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Registre des cas cliniques : excision partielle \u00e0 double longueur d'onde d'une masse r\u00e9nale exophytique<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'ensemble de donn\u00e9es cliniques ci-dessous rend compte d'une intervention chirurgicale en plusieurs \u00e9tapes r\u00e9alis\u00e9e chez un patient pr\u00e9sentant une masse parenchymateuse exophytique et fortement vascularis\u00e9e. L'intervention a fait appel \u00e0 une plateforme \u00e0 double longueur d'onde et haute puissance de fotonmedix.com afin de r\u00e9aliser une r\u00e9section nette sans provoquer de l\u00e9sions thermiques profondes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Profil du patient et diagnostics de base<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u00c2ge \/ Sexe :<\/strong> 54 ans \/ Femme<\/li>\n\n\n\n<li><strong>Pathologie primaire :<\/strong> Masse parenchymateuse r\u00e9nale exophytique (complexit\u00e9 de grade II selon le syst\u00e8me de notation n\u00e9phrom\u00e9trique R.E.N.A.L.)<\/li>\n\n\n\n<li><strong>Pr\u00e9sentation clinique :<\/strong> Une h\u00e9maturie microscopique persistante, une masse localis\u00e9e tr\u00e8s vascularis\u00e9e mesurant 3,2 cm au niveau du p\u00f4le inf\u00e9rieur, situ\u00e9e \u00e0 proximit\u00e9 imm\u00e9diate de la branche segmentaire de l\u2019art\u00e8re r\u00e9nale, et un risque \u00e9lev\u00e9 de prolongation du temps d\u2019isch\u00e9mie \u00e0 temp\u00e9rature normale en cas de recours \u00e0 des sutures par \u00e9lectrocoagulation avec clampage standard.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Matrice des param\u00e8tres laser perop\u00e9ratoires<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Phase de r\u00e9section chirurgicale<\/strong><\/td><td><strong>Phase 1 (ligne d'incision capsulaire)<\/strong><\/td><td><strong>Phase 2 (vaporisation parenchymateuse)<\/strong><\/td><td><strong>Phase 3 (h\u00e9mostase du lit de la plaie)<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Distribution des longueurs d'onde<\/strong><\/td><td>50% \u00e0 980 nm \/ 50% \u00e0 1 470 nm<\/td><td>30% \u00e0 980 nm \/ 70% \u00e0 1 470 nm<\/td><td>80% \u00e0 980 nm \/ 20% \u00e0 1 470 nm<\/td><\/tr><tr><td><strong>Puissance de sortie moyenne<\/strong><\/td><td>30 Watts<\/td><td>25 Watts<\/td><td>15 Watts<\/td><\/tr><tr><td><strong>Mode de modulation d'impulsions<\/strong><\/td><td>100 Hz (mode d'impulsion synchronis\u00e9e)<\/td><td>400 Hz (mode superpuls\u00e9)<\/td><td>Onde continue (mode CW)<\/td><\/tr><tr><td><strong>Fraction du cycle de service<\/strong><\/td><td>Cycle de service 40%<\/td><td>Cycle de service 30%<\/td><td>100% Sortie continue<\/td><\/tr><tr><td><strong>Profil de fluence d'ablation<\/strong><\/td><td>20 joules par millim\u00e8tre carr\u00e9<\/td><td>26 joules par millim\u00e8tre carr\u00e9<\/td><td>10 joules par millim\u00e8tre carr\u00e9<\/td><\/tr><tr><td><strong>Dose d'\u00e9nergie cumul\u00e9e<\/strong><\/td><td>4 800 joules au total<\/td><td>6 500 joules au total<\/td><td>2 200 joules au total<\/td><\/tr><tr><td><strong>H\u00e9mostase au niveau du bord de l'incision<\/strong><\/td><td>Coagulation imm\u00e9diate compl\u00e8te<\/td><td>Ablation nette, sans tra\u00een\u00e9e<\/td><td>Occlusion microvasculaire rapide<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Indicateurs longitudinaux de la r\u00e9cup\u00e9ration postop\u00e9ratoire<\/h3>\n\n\n\n<pre class=\"wp-block-code\"><code>[Jour 0 : Intervention chirurgicale]   -&gt; Excision propre 100%, aucun saignement op\u00e9ratoire, carbonisation des marges  \u0152d\u00e8me local minime, aucune desquamation postop\u00e9ratoire, douleur ma\u00eetris\u00e9e\n |\n[Jour 14 : Cicatrisation]  -&gt; R\u00e9\u00e9pith\u00e9lialisation rapide de la muqueuse, base de granulation propre\n |\n[Jour 30 : Sortie] -&gt; Volume structurel normalis\u00e9, maturation compl\u00e8te des tissus sans cicatrice\n |\n[Suivi \u00e0 12 mois]  -&gt; Aucune r\u00e9cidive, fonction m\u00e9canique parfaitement r\u00e9tablie\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Au cours de la phase initiale de section parenchymateuse, le r\u00e9glage de la longueur d\u2019onde de 1 470 nm \u00e0 la puissance 70% a permis au chirurgien de vaporiser en douceur le tissu r\u00e9nal dense et riche en eau sans exercer de frottement m\u00e9canique. Parall\u00e8lement, l\u2019allocation d\u2019une puissance de 30% pour la longueur d\u2019onde de 980 nm a permis une occlusion microvasculaire continue le long de la paroi de l\u2019incision, pr\u00e9servant ainsi le champ op\u00e9ratoire de tout saignement et rendant inutile l\u2019utilisation d\u2019une pince art\u00e9rielle. Les \u00e9chographies postop\u00e9ratoires r\u00e9alis\u00e9es au quatorzi\u00e8me jour ont confirm\u00e9 que les n\u00e9phrons environnants restaient sains et fonctionnels, la zone de l\u00e9sion thermique lat\u00e9rale \u00e9tant limit\u00e9e \u00e0 moins de 0,15 millim\u00e8tre.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dynamique des cibles chromophores et m\u00e9canismes de coagulation capillaire<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le succ\u00e8s clinique de cette approche \u00e0 double longueur d'onde repose sur le ciblage de pics d'absorption sp\u00e9cifiques au sein de la matrice cellulaire. Selon les mod\u00e8les de transport de la lumi\u00e8re publi\u00e9s par le Beckman Laser Institute, les tissus biologiques pr\u00e9sentent des propri\u00e9t\u00e9s d'absorption tr\u00e8s variables en fonction de la longueur d'onde de la lumi\u00e8re incidente. L'\u00e9nergie laser traversant des zones fortement vascularis\u00e9es est normalement diffus\u00e9e par les fibres de collag\u00e8ne denses, mais le choix de longueurs d'onde pr\u00e9cises permet de concentrer l'\u00e9nergie directement sur les chromophores cibles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'application d'un faisceau int\u00e9gr\u00e9 provenant d'un laser chirurgical haute performance canalise l'\u00e9nergie vers deux r\u00e9ponses physiologiques distinctes simultan\u00e9ment. L'\u00e9nergie \u00e0 1 470 nm est absorb\u00e9e par les mol\u00e9cules d'eau intracellulaires, provoquant une micro-vaporisation localis\u00e9e qui sectionne proprement le tissu. Au m\u00eame micro-point, l\u2019\u00e9nergie \u00e0 980 nm est absorb\u00e9e par l\u2019h\u00e9moglobine cellulaire, provoquant une alt\u00e9ration photothermique rapide des prot\u00e9ines plasmatiques locales. Ce processus forme un bouchon de fibrine s\u00fbr et naturel au niveau des terminaisons capillaires voisines, ce qui permet de maintenir le champ op\u00e9ratoire sec et d\u00e9gag\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De plus, cette approche combin\u00e9e modifie la fa\u00e7on dont l\u2019\u00e9nergie se propage \u00e0 travers les diff\u00e9rentes couches tissulaires. L\u2019\u00e9nergie \u00e0 1 470 nm \u00e9tant absorb\u00e9e tr\u00e8s rapidement par l\u2019eau pr\u00e9sente localement, celle-ci agit comme une barri\u00e8re naturelle qui emp\u00eache le laser de p\u00e9n\u00e9trer trop profond\u00e9ment dans les organes sous-jacents. Ce profil \u00e9nerg\u00e9tique s\u00fbr permet au chirurgien d'intervenir en toute confiance \u00e0 proximit\u00e9 des principaux vaisseaux sanguins ou des voies nerveuses, offrant ainsi une combinaison de vitesse de coupe et de s\u00e9curit\u00e9 que les \u00e9quipements laser chirurgicaux \u00e0 longueur d'onde unique ne peuvent pas fournir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Foire aux questions sur les achats et les op\u00e9rations \u00e0 l'intention des comit\u00e9s d'approvisionnement du secteur de la sant\u00e9<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Quels sont les choix techniques qui influencent les variations de prix d'un appareil laser chirurgical \u00e0 usage commercial ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le prix d\u2019un syst\u00e8me laser chirurgical de qualit\u00e9 m\u00e9dicale d\u00e9pend de trois facteurs principaux : la dur\u00e9e de vie nominale et l\u2019isolation des canaux des r\u00e9seaux de diodes internes, la configuration du syst\u00e8me de refroidissement thermo\u00e9lectrique (TEC) \u00e0 l\u2019\u00e9tat solide, et l\u2019int\u00e9gration de boucles de surveillance automatis\u00e9es pour l\u2019\u00e9talonnage de la puissance. Les syst\u00e8mes \u00e0 bas co\u00fbt font souvent l'impasse sur certains aspects de la fabrication en utilisant des ventilateurs de refroidissement basiques et des cartes \u00e9lectroniques unifi\u00e9es, ce qui entra\u00eene une surchauffe, des baisses de puissance et une d\u00e9faillance pr\u00e9matur\u00e9e des diodes lors d'interventions chirurgicales de longue dur\u00e9e. Investir dans des syst\u00e8mes modulaires dot\u00e9s de circuits de diodes ind\u00e9pendants garantit une alimentation en puissance stable et r\u00e9duit les co\u00fbts de r\u00e9paration \u00e0 long terme.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi une norme de connexion SMA-905 ouverte est-elle importante pour l'acquisition d'\u00e9quipements chirurgicaux \u00e0 laser ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreux fabricants de mat\u00e9riel m\u00e9dical \u00e9quipent leurs appareils de fibres optiques propri\u00e9taires, ce qui oblige les h\u00f4pitaux \u00e0 acheter des c\u00e2bles de rechange co\u00fbteux, sp\u00e9cifiques \u00e0 la marque, pour chaque intervention. En optant pour du mat\u00e9riel dot\u00e9 d\u2019une interface SMA-905 ouverte et non propri\u00e9taire, votre \u00e9quipe d\u2019approvisionnement peut se procurer aupr\u00e8s de fournisseurs ind\u00e9pendants des fibres de quartz universelles de haute qualit\u00e9, renforc\u00e9es d\u2019acier. Cette flexibilit\u00e9 clinique r\u00e9duit consid\u00e9rablement le co\u00fbt par intervention et acc\u00e9l\u00e8re le d\u00e9lai n\u00e9cessaire pour rentabiliser pleinement votre investissement en \u00e9quipement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comment un cycle de service fractionn\u00e9 permet-il de pr\u00e9server la sant\u00e9 du parenchyme \u00e0 proximit\u00e9 des structures organiques fragiles ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les lasers \u00e0 onde continue peuvent entra\u00eener une accumulation rapide de chaleur le long du bord d\u2019une incision, ce qui risque de br\u00fbler les tissus sains voisins et de provoquer une n\u00e9crose cellulaire profonde. Un cycle de service fractionn\u00e9 d\u00e9livre l'\u00e9nergie par salves de l'ordre de la microseconde, cr\u00e9ant ainsi de br\u00e8ves fen\u00eatres de relaxation thermique entre chaque impulsion. Cet intervalle permet \u00e0 la circulation sanguine capillaire locale d'\u00e9vacuer l'exc\u00e8s de chaleur en surface, ce qui garantit une coupe nette et pr\u00e9cise tout en prot\u00e9geant les structures d\u00e9licates voisines contre tout dommage thermique accidentel.<\/p>","protected":false},"excerpt":{"rendered":"<p>Urological surgeons performing laparoscopic or endoscopic partial nephrectomies regularly confront a severe technical contradiction when vaporizing hypervascular parenchyma: the absolute need for deep micro-vascular hemostasis vs. the critical imperative to minimize the lateral necrotic border to preserve functional nephrons. Standard monopolar electrosurgical loops deliver high-voltage current paths that travel indiscriminately through adjacent parenchymal tissues, causing [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[19],"tags":[827],"class_list":["post-15861","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-surgical-laser"],"metadata":{"_edit_lock":["1782107803:1"],"_edit_last":["1"],"_aioseo_title":["Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health"],"_aioseo_description":["A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"catce":["sidebar-widgets4"],"wpil_sync_report3":["1"],"views":["68"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health\" \/>\n\t\t<meta property=\"og:description\" content=\"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-07-03T08:00:54+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-07-03T08:00:54+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health\" \/>\n\t\t<meta name=\"twitter:description\" content=\"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#blogposting\",\"name\":\"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health\",\"headline\":\"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#articleImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"},\"datePublished\":\"2026-07-03T16:00:54+08:00\",\"dateModified\":\"2026-07-03T16:00:54+08:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#webpage\"},\"articleSection\":\"Industry News, Surgical Laser\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/fr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#listItem\",\"name\":\"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#listItem\",\"position\":4,\"name\":\"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/categorie\\\/nouvelles\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/\",\"name\":\"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health\",\"description\":\"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/author\\\/fengmaiadmin\\\/#author\"},\"datePublished\":\"2026-07-03T16:00:54+08:00\",\"dateModified\":\"2026-07-03T16:00:54+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/fr\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health<\/title>\n\n","aioseo_head_json":{"title":"Un laser chirurgical \u00e0 double longueur d'onde pr\u00e9serve la sant\u00e9 du parenchyme","description":"Analyse technique de l'utilisation d'\u00e9quipements chirurgicaux \u00e0 laser de haute puissance \u00e0 1 470 nm et 980 nm pour r\u00e9aliser une coupe pr\u00e9cise du parenchyme tout en minimisant les dommages thermiques.","canonical_url":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#blogposting","name":"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health","headline":"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy","author":{"@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/fr\/#person"},"image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#articleImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"},"datePublished":"2026-07-03T16:00:54+08:00","dateModified":"2026-07-03T16:00:54+08:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#webpage"},"articleSection":"Industry News, Surgical Laser"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/fr","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#listItem","name":"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#listItem","position":4,"name":"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author","url":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#webpage","url":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/","name":"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health","description":"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/fotonmedix.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/fr\/author\/fengmaiadmin\/#author"},"datePublished":"2026-07-03T16:00:54+08:00","dateModified":"2026-07-03T16:00:54+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/fr\/#website","url":"https:\/\/fotonmedix.com\/fr\/","name":"FotonMedix","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/fotonmedix.com\/fr\/#person"}}]},"og:locale":"fr_FR","og:site_name":"FotonMedix |","og:type":"article","og:title":"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health","og:description":"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage.","og:url":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/","article:published_time":"2026-07-03T08:00:54+00:00","article:modified_time":"2026-07-03T08:00:54+00:00","twitter:card":"summary_large_image","twitter:title":"Dual Wavelength Surgical Laser Machine Preserves Parenchymal Health","twitter:description":"A technical analysis of using high-power 1470nm and 980nm surgical laser equipment to achieve precise parenchymal cutting with minimal heat damage."},"aioseo_meta_data":{"post_id":"15861","title":"Un laser chirurgical \u00e0 double longueur d'onde pr\u00e9serve la sant\u00e9 du parenchyme","description":"Analyse technique de l'utilisation d'\u00e9quipements chirurgicaux \u00e0 laser de haute puissance \u00e0 1 470 nm et 980 nm pour r\u00e9aliser une coupe pr\u00e9cise du parenchyme tout en minimisant les dommages thermiques.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-07-03 09:02:14","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-06-22 05:56:11","updated":"2026-07-03 09:02:14"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/fr\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/\" title=\"News\">News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/\" title=\"Industry News\">Industry News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tVolumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/fr"},{"label":"News","link":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/fr\/categorie\/nouvelles\/industry-news\/"},{"label":"Volumetric Vaporization Control Overcomes Hemorrhagic Risks in Endoscopic Partial Partial Nephrectomy","link":"https:\/\/fotonmedix.com\/fr\/volumetric-vaporization-control-overcomes-hemorrhagic-risks-in-endoscopic-partial-partial-nephrectomy.html\/"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts\/15861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/comments?post=15861"}],"version-history":[{"count":2,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts\/15861\/revisions"}],"predecessor-version":[{"id":16160,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/posts\/15861\/revisions\/16160"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/media?parent=15861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/categories?post=15861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/fr\/wp-json\/wp\/v2\/tags?post=15861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}