{"id":14872,"date":"2026-06-15T12:30:22","date_gmt":"2026-06-15T04:30:22","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-06-15T12:30:22","modified_gmt":"2026-06-15T04:30:22","slug":"pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/","title":{"rendered":"L'ottimizzazione della modulazione di impulso limita le perdite di potenza dovute alla micro-flessione nella litotripsia ad alta frequenza"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Il principale problema operativo durante la chirurgia intrarenale retrograda flessibile (RIRS) per i calcoli calicini incastrati \u00e8 il deterioramento della trasmissione ottica causato da sollecitazioni estreme di microflessione all\u2019interno dell\u2019endoscopio flessibile. Quando un conduttore di trasmissione laser \u00e8 sottoposto a una forte deflessione fisica \u2014 che spesso supera i 270 gradi nel polo inferiore profondo del rene \u2014 l\u2019angolo critico per la riflessione totale interna all\u2019interno del nucleo di silice viene alterato. Questa alterazione strutturale costringe una porzione dei fotoni laser a fuoriuscire nel rivestimento circostante e nella guaina protettiva, convertendo l\u2019energia ottica persa in un intenso calore localizzato. Questo accumulo termico localizzato pu\u00f2 fondere la guaina della fibra e distruggere il canale operativo dell\u2019endoscopio. Per risolvere questo dilemma ingegneristico e clinico \u00e8 necessario abbinare una geometria del nucleo ultraflessibile a un\u2019erogazione modulata degli impulsi, al fine di ottenere un\u2019ablazione efficiente dei calcoli a soglie termiche pi\u00f9 basse e pi\u00f9 sicure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Specifiche fototermiche avanzate<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Nucleo di trasmissione dell'apertura<\/strong>: Vetro di silice ad alta purezza ottimizzato per la propagazione di impulsi laser a olmio ad alto picco in condizioni di elevata deflessione.<\/li>\n\n\n\n<li><strong>Contenimento dell'impatto cinetico<\/strong>: Emissione con larghezza d'impulso estesa che converte le onde d'urto meccaniche in un vettore di vaporizzazione termica uniforme.<\/li>\n\n\n\n<li><strong>Irrigazione, idrodinamica, fluidit\u00e0<\/strong>: Profilo fisico ultrasottile che mantiene inalterata l\u2019area della sezione trasversale del canale, garantendo il massimo volume di irrigazione.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Cinetica della dispersione intracorporea tramite profili di potenza di picco attenuati<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per ottenere la rimozione completa di calcoli renali complessi mediante litotripsia con laser ad olmio \u00e8 necessario gestire la relazione fisica tra l\u2019energia laser, l\u2019assorbimento d\u2019acqua e la struttura del calcolo. I calcoli urinari sono strutture complesse composte da strati minerali cristallini legati tra loro da una matrice di mucoproteine. L\u2019obiettivo clinico delle moderne procedure endourologiche \u00e8 quello di utilizzare impulsi laser ad alta frequenza per frantumare questi blocchi minerali densi direttamente in polvere microgranulare fine, eliminando il rischio che frammenti taglienti rimangano incastrati nell\u2019uretere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I metodi tradizionali di emissione del laser a impulsi brevi presentano spesso evidenti svantaggi meccanici quando vengono utilizzati all\u2019interno della delicata pelvi renale. Gli impulsi laser brevi erogano energia in brevi raffiche ad alta energia, generando una violenta onda d\u2019urto meccanica quando l\u2019energia colpisce il calcolo. Questo impatto cinetico provoca una forte retropulsione del calcolo, che viene respinto dalla punta della fibra e spinto pi\u00f9 in profondit\u00e0 nei calici renali, frammentandosi al contempo in pezzi grandi e taglienti che richiedono la rimozione manuale con cestelli di estrazione.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>[Emissione mirata di impulsi brevi] \u2500\u2500\u2500\u25ba Elevata potenza di picco \u2500\u2500\u2500\u25ba Onda d'urto cinetica \u2500\u2500\u2500\u25ba Retropulsione\n \u2502\n \u25bc\n [Pietra in movimento \/ Elevato rischio di fuori bersaglio]\n\n[Emissione di impulsi lunghi sul bersaglio]  \u2500\u2500\u2500\u25ba Bassa potenza di picco  \u2500\u2500\u2500\u25ba Vaporizzazione termica \u2500\u2500\u2500\u25ba Polvere di calcoli inferiore a 1 mm\n \u2502\n \u25bc\n [Zona di eliminazione stabile dei frammenti]\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">L'utilizzo di una configurazione con laser ad olmio a impulso lungo e regolato modifica radicalmente questa dinamica di ablazione. Estendendo la durata di ciascun impulso, il sistema riduce la potenza di picco mantenendo invariata l\u2019energia totale emessa ($J$). Anzich\u00e9 infliggere un violento colpo fisico, l\u2019impulso prolungato trasferisce l\u2019energia in modo graduale nelle micro-sacche d\u2019acqua intrappolate all\u2019interno del reticolo cristallino del calcolo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'acqua evapora istantaneamente, generando una delicata espansione fototermica che frantuma gli strati superficiali della pietra in polvere di dimensioni inferiori al millimetro. Questa dissoluzione controllata mantiene la pietra da trattare completamente stabile sulla punta della fibra, consentendo un'ablazione continua e riducendo significativamente la durata complessiva della procedura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per convogliare questa energia in modo sicuro negli spazi caliciali completamente deflessi, il sistema di trasmissione deve essere il pi\u00f9 sottile e flessibile possibile. L\u2019utilizzo di una fibra ottica medica da 272um garantisce il profilo sottile e altamente flessibile necessario per passare agevolmente attraverso i canali operativi stretti e curvi dei moderni ureteroscopi digitali. Un diametro del nucleo di 272 \u00b5m riduce significativamente l\u2019attrito fisico all\u2019interno del canale dello strumento, consentendo a quest\u2019ultimo di mantenere la sua piena escursione di flessione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questa flessibilit\u00e0 consente all\u2019operatore di raggiungere e trattare i calcoli presenti nei calici del polo inferiore senza esercitare sollecitazioni meccaniche sui cavi di sterzo interni dell\u2019endoscopio, proteggendo cos\u00ec le costose apparecchiature dall\u2019usura prematura e dai danni strutturali.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Protezione delle apparecchiature endoscopiche tramite la stabilizzazione Micro-Core<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il controllo delle perdite energetiche durante la polverizzazione ad alta frequenza dipende in larga misura dalle dimensioni fisiche e dall\u2019allineamento del nucleo della fibra. La flessibilit\u00e0 di una fibra \u00e8 inversamente proporzionale alla quarta potenza del diametro del suo nucleo, il che significa che anche piccole riduzioni dello spessore della fibra comportano notevoli miglioramenti nella flessibilit\u00e0 di piegatura.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Diametro del nucleo: 365 um \u2500\u2500\u2500\u25ba Elevata rigidit\u00e0 \u2500\u2500\u2500\u25ba Limita la deflessione del cavo \u2500\u2500\u2500\u25ba Elevata perdita di energia per microflessione\nDiametro del nucleo 272 \u00b5m \u2500\u2500\u2500\u25ba Ultraflessibile \u2500\u2500\u2500\u25ba Mantiene la deflessione completa  \u2500\u2500\u2500\u25ba Riflessione interna totale ottimale\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Quando si utilizza una fibra ottica medica ultraflessibile da 272 um al posto di alternative pi\u00f9 spesse, il nucleo in silice sopporta facilmente curve strette senza che la luce fuoriesca attraverso lo strato di rivestimento. Questa configurazione stabile garantisce che l\u2019energia del laser ad olmio rimanga focalizzata in modo sicuro al centro del nucleo della fibra, prevenendo i picchi di calore localizzati che potrebbero bruciare il rivestimento della fibra e distruggere il canale operativo dell\u2019endoscopio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questa maggiore trasmissione di energia consente agli operatori clinici di utilizzare in tutta sicurezza impostazioni di spolveramento ad alta frequenza per lunghi periodi, garantendo eccellenti prestazioni di ablazione del dente e preservando al contempo la sicurezza delle apparecchiature operative.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Registro dei casi clinici: espulsione ad alta frequenza di un calcolo ureterico superiore incastrato<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">I dati clinici riportati di seguito illustrano una procedura di litotripsia con laser ad olmio eseguita con successo utilizzando il sistema FotonMedix LaserMedix 3000U5, dimostrando l\u2019efficacia della frantumazione dei calcoli in posizioni anatomiche anguste e con deflessione completa.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Parametro clinico<\/strong><\/td><td><strong>Indicatori di rendimento dei pazienti<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Profilo del paziente<\/strong><\/td><td>Donna di 51 anni<\/td><\/tr><tr><td><strong>Valori di riferimento patologici<\/strong><\/td><td>Calcolo denso di 11 mm incastrato a livello della giunzione ureteropelvica (UPJ)<\/td><\/tr><tr><td><strong>Densit\u00e0 della composizione<\/strong><\/td><td>Miscela di ossalato di calcio diidrato (misura CT: 1050 unit\u00e0 Hounsfield)<\/td><\/tr><tr><td><strong>Sistema di emissione laser<\/strong><\/td><td>Nucleo di un laser ad olmio a impulso lungo modulato<\/td><\/tr><tr><td><strong>Dimensioni del nucleo in fibra<\/strong><\/td><td>Fibra ottica medica con nucleo in silice ad alta purezza da 272 \u00b5m<\/td><\/tr><tr><td><strong>Energia erogata per impulso<\/strong><\/td><td>Impostazione a bassa energia: 0,4 joule<\/td><\/tr><tr><td><strong>Selezione della frequenza del impulso<\/strong><\/td><td>Configurazione ad alta frequenza a 50 Hertz<\/td><\/tr><tr><td><strong>Potenza operativa totale<\/strong><\/td><td>Potenza in uscita regolata: 20 Watt<\/td><\/tr><tr><td><strong>Energia cumulativa erogata<\/strong><\/td><td>6.400 joule di energia erogata complessivamente durante la seduta<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Calendario delle valutazioni post-operatorie<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Stato intraoperatorio<\/strong>: L'endoscopio flessibile ha raggiunto il posizionamento anatomico completo senza alcuna resistenza nel canale; il calcolo \u00e8 stato frantumato sul posto senza alcuna retropulsione o spostamento.<\/li>\n\n\n\n<li><strong>1\u00b0 giorno dopo l'intervento<\/strong>: La radiografia standard conferma la completa rimozione della massa litica primaria; le particelle residue sono inferiori a 1 mm; il paziente riferisce un basso livello di dolore (2\/10) grazie all\u2019assunzione di analgesici per via orale.<\/li>\n\n\n\n<li><strong>Settimana 4 dopo l'intervento<\/strong>: L'ecografia di controllo conferma la completa rimozione di tutte le particelle di polvere residue; nessun segno di idronefrosi o stenosi ureterale; ripristinato il normale flusso urinario.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Miglioramento dell'uniformit\u00e0 dell'ablazione tramite tecniche di \"painting\" continuo<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per ottenere una vaporizzazione efficiente e completa dei calcoli duri \u00e8 necessario combinare le impostazioni del laser a impulso lungo con una tecnica di spostamento manuale sistematica in corrispondenza dell\u2019interfaccia con il calcolo. Durante una procedura di litotripsia con laser ad olmio, l\u2019operatore allinea la punta della fibra ottica medica da 272 \u00b5m con la superficie esterna del calcolo sotto visualizzazione digitale diretta.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>                  [Punta in fibra Advance da 272um]\n \u2502\n \u25bc\n [Movimento di verniciatura continuo] \u2500\u2500\u2500\u25ba Scorre lungo la superficie della pietra da un lato all\u2019altro\n \u2502\n \u25bc\n  [Campo di microbolle di vapore]   \u2500\u2500\u2500\u25ba Dissolve delicatamente la crosta superficiale\n \u2502\n \u25bc\n  [Rimozione spontanea della polvere] \u2500\u2500\u2500\u25ba Elimina la necessit\u00e0 di cestelli di raccolta\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Muovendo la punta della fibra con un movimento costante, da un lato all\u2019altro, come se si dipingesse, lungo la superficie della pietra, si garantisce che l\u2019energia laser dissolva il calcolo in modo uniforme, strato dopo strato. Quando l\u2019energia pulsata interagisce con la superficie del calcolo, crea un campo di vapore localizzato che scompone il guscio minerale duro direttamente in un fine sedimento, che viene continuamente espulso dal rene dal liquido di irrigazione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questo approccio sistematico alla verniciatura impedisce alla pietra di frammentarsi in pezzi grandi e irregolari, eliminando la necessit\u00e0 di noiose operazioni di recupero con cestello. Poich\u00e9 l\u2019energia termica \u00e8 confinata in una zona ristretta di 0,4 mm sulla punta della fibra, le pareti ureterali circostanti e il tessuto mucoso sensibile sono completamente protetti da danni accidentali causati dal calore. Questo controllo preciso offre ai responsabili degli acquisti nel settore medico B2B una soluzione altamente affidabile ed economicamente vantaggiosa che riduce i tempi degli interventi e ottimizza gli standard di sicurezza dei pazienti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Domande frequenti su aspetti tecnici e appalti<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">In che modo il diametro del nucleo della fibra di 272 um migliora il flusso dell'irrigazione salina rispetto a una fibra da 365 um?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">All\u2019interno di un canale operatorio standard da 3,6 French di un ureteroscopio flessibile, una fibra ottica medica da 272 um occupa uno spazio trasversale significativamente inferiore rispetto a una fibra da 365 um. Questa differenza di dimensioni lascia oltre 40% di area libera in pi\u00f9 all\u2019interno del canale, consentendo un flusso molto pi\u00f9 elevato di soluzione salina per l\u2019irrigazione. Questo aumento di flusso \u00e8 essenziale per mantenere il campo operatorio libero dalla polvere di calcoli e per raffreddare la pelvi renale durante le procedure di polverizzazione ad alta frequenza.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Perch\u00e9 un laser ad olmio a impulso lungo modulato riduce il rischio di carbonizzazione della punta della fibra?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le impostazioni tradizionali a impulso breve erogano energia in raffiche improvvise e di picco elevato che generano un calore localizzato intenso, in grado di fondere rapidamente la punta della fibra e di far aderire i detriti tissutali al vetro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le impostazioni con impulsi lunghi modulati distribuiscono l'energia laser su un arco di tempo pi\u00f9 lungo, riducendo la temperatura di picco sulla punta. Questo rilascio pi\u00f9 graduale dell'energia impedisce il surriscaldamento del vetro e riduce la carbonizzazione dei tessuti, garantendo una trasmissione costante della potenza laser durante i trattamenti prolungati.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quali protocolli di controllo deve seguire il personale clinico prima di inserire una fibra da 272 um in un endoscopio flessibile?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prima dell\u2019inserimento, il personale deve ispezionare l\u2019intera lunghezza della fibra da 272 \u00b5m alla ricerca di eventuali crepe visibili, piegature o difetti dell\u2019isolamento utilizzando una lente di ingrandimento standard. L\u2019endoscopio deve essere tenuto completamente dritto durante il processo di inserimento per evitare che la punta della fibra si impigli e fori il rivestimento del canale interno. Infine, il connettore laser SMA-905 deve essere controllato con uno strumento per endoscopia a fibra per assicurarsi che sia pulito e privo di polvere o tracce di olio, evitando cos\u00ec riflessi di energia che potrebbero danneggiare le porte di allineamento interne del sistema laser.<\/p>","protected":false},"excerpt":{"rendered":"<p>The primary operational failure during flexible retrograde intrarenal surgery (RIRS) for impacted calyceal calculi is the degradation of optical transmission caused by extreme micro-bending stress within the flexible endoscope. When a laser transmission conduit is subjected to severe physical deflection\u2014often exceeding 270 degrees in the deep lower pole of the kidney\u2014the critical angle for internal [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[19],"tags":[],"class_list":["post-14872","post","type-post","status-publish","format-standard","hentry","category-industry-news"],"metadata":{"_edit_lock":["1781146276:1"],"_edit_last":["1"],"_aioseo_title":["Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion"],"_aioseo_description":["See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes."],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"catce":["sidebar-widgets4"],"wpil_sync_report3":["1"],"views":["44"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.8 - aioseo.com -->\n\t<meta name=\"description\" content=\"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.8\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion\" \/>\n\t\t<meta property=\"og:description\" content=\"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-06-15T04:30:22+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-06-15T04:30:22+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion\" \/>\n\t\t<meta name=\"twitter:description\" content=\"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#blogposting\",\"name\":\"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion\",\"headline\":\"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#articleImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"},\"datePublished\":\"2026-06-15T12:30:22+08:00\",\"dateModified\":\"2026-06-15T12:30:22+08:00\",\"inLanguage\":\"it-IT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#webpage\"},\"articleSection\":\"Industry News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/it\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news\\\/#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#listItem\",\"name\":\"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#listItem\",\"position\":4,\"name\":\"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin\\\/#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin\\\/\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/\",\"name\":\"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion\",\"description\":\"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes.\",\"inLanguage\":\"it-IT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin\\\/#author\"},\"datePublished\":\"2026-06-15T12:30:22+08:00\",\"dateModified\":\"2026-06-15T12:30:22+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"it-IT\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion<\/title>\n\n","aioseo_head_json":{"title":"Il trattamento con laser ad olmio a impulso lungo elimina la retropulsione della pietra","description":"Scoprite come la combinazione di un laser ad olmio a impulso lungo con una fibra ottica medica ultraflessibile da 272 um ottimizzi la polverizzazione dei calcoli, proteggendo al contempo gli endoscopi flessibili.","canonical_url":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#blogposting","name":"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion","headline":"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy","author":{"@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin\/#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/it\/#person"},"image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#articleImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"},"datePublished":"2026-06-15T12:30:22+08:00","dateModified":"2026-06-15T12:30:22+08:00","inLanguage":"it-IT","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#webpage"},"articleSection":"Industry News"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/it","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\/#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\/#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#listItem","name":"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#listItem","position":4,"name":"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\/#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin\/#author","url":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin\/","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#webpage","url":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/","name":"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion","description":"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes.","inLanguage":"it-IT","isPartOf":{"@id":"https:\/\/fotonmedix.com\/it\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin\/#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin\/#author"},"datePublished":"2026-06-15T12:30:22+08:00","dateModified":"2026-06-15T12:30:22+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/it\/#website","url":"https:\/\/fotonmedix.com\/it\/","name":"FotonMedix","inLanguage":"it-IT","publisher":{"@id":"https:\/\/fotonmedix.com\/it\/#person"}}]},"og:locale":"it_IT","og:site_name":"FotonMedix |","og:type":"article","og:title":"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion","og:description":"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes.","og:url":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/","article:published_time":"2026-06-15T04:30:22+00:00","article:modified_time":"2026-06-15T04:30:22+00:00","twitter:card":"summary_large_image","twitter:title":"Long Pulse Holmium Laser Dusting Eliminates Stone Retropulsion","twitter:description":"See how combining a long-pulse holmium laser with an ultra-flexible 272um medical optical fiber optimizes stone dusting while protecting flexible endoscopes."},"aioseo_meta_data":{"post_id":"14872","title":"Il trattamento con laser ad olmio a impulso lungo elimina la retropulsione della pietra","description":"Scoprite come la combinazione di un laser ad olmio a impulso lungo con una fibra ottica medica ultraflessibile da 272 um ottimizzi la polverizzazione dei calcoli, proteggendo al contempo gli endoscopi flessibili.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-06-11 02:47:12","updated":"2026-06-15 04:53:55"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/it\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/\" title=\"News\">News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\/\" title=\"Industry News\">Industry News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tPulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/it"},{"label":"News","link":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\/"},{"label":"Pulse Modulation Optimization Restricts Micro-Bending Power Losses in High-Frequency Lithotripsy","link":"https:\/\/fotonmedix.com\/it\/pulse-modulation-optimization-restricts-micro-bending-power-losses-in-high-frequency-lithotripsy.html\/"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts\/14872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/comments?post=14872"}],"version-history":[{"count":2,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts\/14872\/revisions"}],"predecessor-version":[{"id":14929,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts\/14872\/revisions\/14929"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/media?parent=14872"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/categories?post=14872"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/tags?post=14872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}