{"id":17596,"date":"2026-09-13T19:30:02","date_gmt":"2026-09-13T11:30:02","guid":{"rendered":"https:\/\/fotonmedix.com\/?p=17596"},"modified":"2026-09-13T19:30:02","modified_gmt":"2026-09-13T11:30:02","slug":"multi-band-photons-resolve-canine-lumbosacral-stenosis","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html","title":{"rendered":"I fotoni multibanda risolvono la stenosi lombosacrale nei cani"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian Malinois police patrol dog arrives at the referral center exhibiting pronounced pelvic limb weakness, extreme difficulty rising from down positions, and acute pain vocalization upon direct lordosis testing of the L7-S1 junction. Lumbosacral magnetic resonance imaging reveals severe intervertebral disc protrusion at L7-S1, marked ligamentum flavum hypertrophy, foraminal stenosis, and severe compression of the descending cauda equina nerve roots. Long-term systemic administration of prednisone and meloxicam has induced iatrogenic Cushingoid symptoms and recurrent gastrointestinal bleeding, forcing pharmaceutical withdrawal. When clinicians attempt conservative rehabilitation using low-output units, shallow light scatters across dense lumbodorsal fascia and heavy epaxial musculature, delivering zero measurable joules to the inflamed cauda equina seated six to eight centimeters beneath the skin. Clinicians deploying vet laser therapy find that underpowered devices fail to alter nerve conduction velocity, tying up technicians for forty unproductive minutes while the dog remains in debilitating pain.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Optical Penetration Physics Through Dense Paraspinal Architecture<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Delivering therapeutic photon levels to the canine lumbosacral junction requires navigating massive biological obstacles. The descending nerve roots of the cauda equina sit protected beneath dense skin, heavy subcutaneous fat, the thick thoracolumbar fascia, and bulky longissimus lumborum muscle groups. Photons directed at the L7-S1 interlaminar space encounter severe biological attenuation driven by Rayleigh scattering from microscopic collagen fibrils and Mie scattering from large cellular organelle interfaces.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In dense myofascial and osseous structures, scattering coefficients far outweigh absorption coefficients across shallow visible wavelengths. Sub-watt therapeutic devices deliver inadequate photon flux to penetrate these dense layers. Light scatters within the first few millimeters of superficial dermis, failing to reach the biological fluence threshold of four to eight Joules per square centimeter required to initiate neurocellular repair cascades at deep nerve targets. Delivering therapeutic doses to compressed spinal nerves demands high initial surface irradiance delivered through optimized optical pathways.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Biological dose-response behavior governed by the Arndt-Schulz law dictates that sub-therapeutic photon densities fail to stimulate cellular pathways, while unmodulated continuous energy risks photothermal damage. High-intensity Class IV systems deliver the exact photon density required to break through tough paraspinal envelopes while keeping surface tissues well within safe biological limits.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When high-fluence photons reach compressed motor neurons, Schwann cells, and surrounding fibrous stroma, cytochrome c oxidase within mitochondrial respiratory chain complex IV absorbs the radiation. This stimulates the immediate displacement of inhibitory nitric oxide, restoring electron transport and elevating mitochondrial proton gradients. The resulting surge in adenosine triphosphate production provides the metabolic energy needed to clear neurotoxic debris, support axonal membrane repolarization, and downregulate pro-inflammatory cytokines, including tumor necrosis factor-alpha and interleukin-one beta.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sincronizzazione di due cromofori negli spettri a 980 nm e 1470 nm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Severe lumbosacral stenosis presents two distinct physical obstacles: persistent microvascular ischemia within compressed nerve roots, and water-dense, fibrinous inflammatory edema within the tight neural canal. Monochromatic laser therapy cannot treat both pathological targets effectively. Achieving complete neurovascular salvage requires coordinating complementary wavelengths targeting specific biological chromophores.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La lunghezza d\u2019onda di 980 nm presenta un picco di assorbimento nell\u2019emoglobina deossigenata e ossigenata, associato a una moderata interazione con l\u2019acqua. Le radici nervose spinali intrappolate soffrono di ischemia meccanica e stasi capillare secondaria. L\u2019erogazione di energia a 980 nm induce una vasodilatazione fototermica localizzata all\u2019interno delle reti capillari radicolari collaterali, eliminando i sottoprodotti metabolici acidi e convogliando sangue ossigenato nel tessuto nervoso ipossico. Questo stimolo vascolare innesca il passaggio dei macrofagi dai fenotipi M1 pro-infiammatori a quelli M2 pro-risolutivi, accelerando la riparazione dei tessuti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The 1470nm wavelength interacts directly with intracellular and interstitial water molecules. Its absorption coefficient in water is forty times higher than that of wavelengths in the 800nm to 900nm window. Chronic stenosis is accompanied by dense epidural edema and perineural effusion that elevate compartment pressure inside the vertebral canal. Direct application of 1470nm photon emissions excites water molecules, altering local tissue hydraulic pressure and accelerating lymphatic clearance to relieve pressure within the tight intervertebral foramen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Coordinating 980nm and 1470nm emissions within a synchronized delivery beam creates targeted clinical synergy. The 980nm wavelength restores microvascular circulation and cellular respiration, while the 1470nm wavelength disperses dense fluid pockets that would otherwise scatter forward-traveling light. Clinicians operating a dedicated <a href=\"https:\/\/fotonmedix.com\/it\/resolving-canine-calcaneal-tendinopathy-and-scar-stagnation.html\/\"  data-wpil-monitor-id=\"4870\">macchina per laserterapia canina<\/a> or comprehensive equine laser therapy machine require this dual-action capability to break down fibrous barriers and deliver restorative photon energy straight into damaged neurological structures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Tempo di rilassamento termico e modulazione dinamica del ciclo di lavoro<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L'applicazione di un'elevata potenza media alla densa muscolatura lombosacrale comporta un rischio clinico ben definito: la lesione termica cutanea. Il pelo ruvido e le strutture dermiche ricche di melanina assorbono rapidamente i fotoni, convertendo l'energia radiante in calore. Senza un preciso controllo temporale, la temperatura dei tessuti supera rapidamente la soglia critica di quarantatr\u00e9 gradi Celsius, oltre la quale le proteine cellulari subiscono denaturazione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per superare questa barriera termica \u00e8 necessario adeguare l\u2019erogazione di energia al tempo di rilassamento termico del tessuto animale. Il tempo di rilassamento termico rappresenta il tempo necessario affinch\u00e9 uno strato di tessuto biologico perda il cinquanta per cento del calore accumulato attraverso la dissipazione microvascolare naturale. Il derma canino presenta costanti di rilassamento termico nell\u2019ordine dei millisecondi. L\u2019emissione laser a onda continua immette calore negli strati superficiali pi\u00f9 rapidamente di quanto il flusso sanguigno capillare riesca a dissiparlo, creando picchi termici dolorosi.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"395\" height=\"373\" src=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/09\/laser-therapy-for-dogs247.jpg\" alt=\"Laser therapy for dogs247\" class=\"wp-image-17600\" srcset=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/09\/laser-therapy-for-dogs247.jpg 395w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/09\/laser-therapy-for-dogs247-300x283.jpg 300w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/09\/laser-therapy-for-dogs247-13x12.jpg 13w\" sizes=\"auto, (max-width: 395px) 100vw, 395px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">I cicli di funzionamento a impulsi risolvono questo problema convertendo l'emissione continua di fotoni in rapidi microimpulsi separati da vere e proprie pause di rilassamento termico. Operando con cicli di funzionamento compresi tra il venti e il quaranta per cento, \u00e8 possibile ottenere potenze di picco elevate in grado di attraversare la spessa muscolatura paraspinale, mentre le pause intermedie a emissione zero consentono ai tessuti superficiali di raffreddarsi naturalmente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La regolazione della frequenza cardiaca determina effetti biologici ben distinti:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le frequenze comprese tra dieci e cento hertz stabilizzano le fibre nervose nocicettive periferiche, attenuando la trasmissione del dolore lungo le fibre C non mielinizzate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le frequenze comprese tra cinquecento e mille Hertz stimolano contrazioni linfatiche localizzate, favorendo l'eliminazione degli versamenti infiammatori persistenti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le frequenze comprese tra duemila e diecimila Hertz massimizzano l'assorbimento della citocromo c ossidasi all'interno dei neuroni e delle cellule di Schwann, accelerando la ramificazione assonale e il rimodellamento della guaina mielinica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Deploying balanced pulse gating on a versatile veterinary laser therapy machine allows clinicians to deliver deep volumetric dosages through dense connective tissues without causing skin burns or animal agitation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Architettura comparativa tra piattaforme veterinarie di Classe IV<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per orientarsi tra le apparecchiature terapeutiche \u00e8 necessario valutare chiare differenze fisiche. Le penne a bassa potenza, i tappetini superficiali e le unit\u00e0 chirurgiche a funzionamento continuo non dispongono delle dinamiche del fascio, della profondit\u00e0 ottica e della gestione termica necessarie per il trattamento di patologie profonde del midollo spinale e di malattie articolari croniche negli animali. La scelta del sistema ad alta potenza pi\u00f9 adatto richiede un confronto diretto delle specifiche fisiche.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Metrica operativa<\/strong><\/td><td><strong>Unit\u00e0 di raffreddamento a basso livello<\/strong><\/td><td><strong>Unit\u00e0 a onda singola continua di Classe IV<\/strong><\/td><td><strong>Sistemi dinamici a onde multiple di classe IV<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Potenza di picco ottica<\/td><td>0,2 W \u2013 0,5 W<\/td><td>10 W \u2013 15 W in funzionamento continuo<\/td><td>15 W \u2013 30 W (picco con modulazione a gate)<\/td><\/tr><tr><td>Lunghezze d'onda delle emissioni<\/td><td>635 nm \u2013 810 nm, monomodale<\/td><td>Esclusivamente 810 nm o 980 nm<\/td><td>980 nm + 1470 nm sincronizzati<\/td><\/tr><tr><td>Profondit\u00e0 di penetrazione cutanea<\/td><td>da 5 mm a 10 mm<\/td><td>da 25 mm a 35 mm<\/td><td>Da 50 mm a 80 mm nelle strutture spinali profonde<\/td><\/tr><tr><td>Rischio di accumulo di calore cutaneo<\/td><td>Assente<\/td><td>Elevato con movimento lento del manipolo<\/td><td>Regolato tramite raffreddamento a ciclo di lavoro con gate<\/td><\/tr><tr><td>Focus clinico<\/td><td>Ferite cutanee superficiali, otite<\/td><td>Stiramenti muscolari superficiali generalizzati<\/td><td>Degenerate lumbosacral stenosis, cauda equina<\/td><\/tr><tr><td>Durata del trattamento della colonna vertebrale canina<\/td><td>da 40 a 50 minuti<\/td><td>Da 15 a 20 minuti<\/td><td>Da 6 a 8 minuti per regione spinale<\/td><\/tr><tr><td>Cromofori cellulari bersaglio<\/td><td>Solo citocromo c ossidasi<\/td><td>Citocromo c ossidasi o emoglobina<\/td><td>Citocromo c ossidasi, emoglobina e acqua<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Equipping a specialty rehabilitation center with hardware that pairs high peak power with distinct multi-wavelength options ensures adequate depth penetration across large and small animal clinical presentations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Protocollo relativo a un caso clinico documentato<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Il seguente caso clinico documentato illustra l'applicazione della fotobiomodulazione della colonna vertebrale profonda in uno studio clinico di neuro-ortopedia per piccoli animali.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Case File Reference: VET-NEURO-2026-4481<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Subject: Canine, Belgian Malinois, Intact Male<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Age: 8 Years 2 Months<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Weight: 34.2 kg<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Confirmed Diagnosis: Severe Degenerative Lumbosacral Stenosis (DLSS) at L7-S1 characterized by dorsal disc protrusion, secondary foraminal stenosis, and severe bilateral compression of the cauda equina nerve roots. Confirmed via high-field MRI and computed tomographic myelography.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prior Therapy: Oral prednisone administered at 0.5 mg\/kg once daily for six weeks combined with gabapentin at 10 mg\/kg three times daily; discontinued due to progressive iatrogenic hyperadrenocorticism and gastrointestinal erosions. Surgical dorsal laminectomy was declined by handlers due to career-ending prognosis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clinical Presentation: Grade 3\/5 pelvic limb paresis, severe reluctance to jump into transport vehicles, marked kyphotic pelvic posture, painful vocalization upon L7-S1 hyperextension (lordosis test), and bilateral delayed proprioceptive positioning in pelvic limbs. Marked bilateral atrophy of the biceps femoris and semitendinosus muscle groups.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Protocollo terapeutico clinico completo<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Indice delle sessioni<\/strong><\/td><td><strong>Cronologia trascorsa<\/strong><\/td><td><strong>Bilanciamento della lunghezza d'onda (980 nm \/ 1470 nm)<\/strong><\/td><td><strong>Potenza di picco in funzionamento (W)<\/strong><\/td><td><strong>Frequenza di impulso e ciclo di lavoro<\/strong><\/td><td><strong>Energia totale erogata (joule)<\/strong><\/td><td><strong>Fluence sulla superficie cutanea (J\/cm\u00b2)<\/strong><\/td><td><strong>Osservazioni cliniche e tappe fondamentali della biomeccanica<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Sessione 1<\/td><td>Giorno 1<\/td><td>75% \/ 25%<\/td><td>14,0 W<\/td><td>50 Hz, ciclo di lavoro 30%<\/td><td>4.200 J<\/td><td>21 J\/cm\u00b2<\/td><td>Severe myofascial tension; continuous sweeping applied across L6-S2 paraspinal borders; patient settled calmly.<\/td><\/tr><tr><td>Sessione 2<\/td><td>Giorno 3<\/td><td>70% \/ 30%<\/td><td>16,0 W<\/td><td>50 Hz, ciclo di lavoro 35%<\/td><td>4.800 J<\/td><td>24 J\/cm\u00b2<\/td><td>Marked reduction in superficial paraspinal spasms; improved tolerance to firm palpation over the lumbosacral junction.<\/td><\/tr><tr><td>Sessione 3<\/td><td>Giorno 6<\/td><td>65% \/ 35%<\/td><td>18,0 W<\/td><td>100 Hz, ciclo di lavoro 40%<\/td><td>5,400 J<\/td><td>27 J\/cm\u00b2<\/td><td>Delayed proprioception returned to normal in right pelvic limb; dog rises from recumbency with noticeably less effort.<\/td><\/tr><tr><td>Sessione 4<\/td><td>Giorno 9<\/td><td>60% \/ 40%<\/td><td>20,0 W<\/td><td>250 Hz, ciclo di lavoro 40%<\/td><td>6,000 J<\/td><td>30 J\/cm\u00b2<\/td><td>Pelvic limb stride length increased during trot; lordosis test produced minimal resistance or discomfort.<\/td><\/tr><tr><td>Sessione 5<\/td><td>Giorno 14<\/td><td>50% \/ 50%<\/td><td>22,0 W<\/td><td>500 Hz, ciclo di lavoro 45%<\/td><td>6,600 J<\/td><td>33 J\/cm\u00b2<\/td><td>Follow-up neurological testing showed normal postural reactions bilateral; dog clears vehicle entry ramp without refusal.<\/td><\/tr><tr><td>Sessione 6<\/td><td>Giorno 19<\/td><td>50% \/ 50%<\/td><td>24,0 W<\/td><td>1.000 Hz, ciclo di lavoro 45%<\/td><td>7,200 J<\/td><td>36 J\/cm\u00b2<\/td><td>Paresis resolved; dog voluntarily initiating canter during exercise; thigh circumference increased by 1.8 cm bilateral.<\/td><\/tr><tr><td>Sessione 7<\/td><td>Giorno 25<\/td><td>40% \/ 60%<\/td><td>25,0 W<\/td><td>2.500 Hz, ciclo di lavoro 50%<\/td><td>7,500 J<\/td><td>37,5 J\/cm\u00b2<\/td><td>Agility foundation obstacle negotiation resumed; zero reactive heat, pain, or spinal stiffness post-training.<\/td><\/tr><tr><td>Sessione 8<\/td><td>Giorno 33<\/td><td>40% \/ 60%<\/td><td>25,0 W<\/td><td>5.000 Hz, ciclo di lavoro 50%<\/td><td>7,500 J<\/td><td>37,5 J\/cm\u00b2<\/td><td>Glasgow composite pain score dropped to 0\/10; symmetrical hindlimb muscle engagement verified on pressure sensor mat.<\/td><\/tr><tr><td>Sessione 9<\/td><td>Giorno 45<\/td><td>50% \/ 50%<\/td><td>20,0 W<\/td><td>1.000 Hz, ciclo di lavoro 40%<\/td><td>6,000 J<\/td><td>30 J\/cm\u00b2<\/td><td>Maintenance phase entry; dog engaged in full thirty-minute obedience drills without post-exercise fatigue.<\/td><\/tr><tr><td>Sessione 10<\/td><td>Giorno 60<\/td><td>50% \/ 50%<\/td><td>18,0 W<\/td><td>500 Hz, ciclo di lavoro 35%<\/td><td>5,400 J<\/td><td>27 J\/cm\u00b2<\/td><td>Full clinical recovery; cleared for active service duty; complete resolution of iatrogenic pharmaceutical side effects.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Therapy was delivered using an ergonomic divergent contact handpiece held perpendicular to the clipped dorsal lumbosacral region. Longitudinal and cross-frictional strokes were administered continuously to treat the L6-S2 dorsal lamina, the exiting sciatic nerve roots, and adjacent epaxial muscle masses across a treatment area of approximately two hundred square centimeters.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Risultati clinici e integrazione nella pratica clinica<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Relying exclusively on systemic corticosteroids and non-steroidal anti-inflammatory drugs for canine degenerative lumbosacral stenosis carries substantial clinical risks. Suppressing inflammatory cascades masks progressive nerve root entrapment without addressing mechanical compression or local microvascular ischemia. Prolonged pharmaceutical use frequently causes severe gastric ulceration, iatrogenic Cushing&#8217;s syndrome, and hepatic strain, leaving clinicians with few options once drug toxicity forces treatment cessation. Furthermore, decompressive dorsal laminectomy carries high financial costs, significant post-operative morbidity, and risk of fibrous scar tissue formation that can re-compress the cauda equina, often ending a working dog&#8217;s active service career.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">High-power Class IV multi-wavelength laser therapy provides a non-invasive, drug-free alternative that targets the biological roots of neurovascular breakdown. Coordinating 980nm microvascular stimulation with 1470nm water absorption delivers therapeutic photons through dense paraspinal musculature directly into the damaged cauda equina canal. Cellular ATP production increases, micro-ischemia clears, and chronic inflammatory effusions drain through stimulated lymphatic routes without requiring surgical cutting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Integrating an advanced veterinary laser platform into daily clinical workflows improves treatment efficiency and elevates patient care standards. Rehabilitation protocols wrap up in under eight minutes per anatomical site, and measurable biomechanical improvements appear within four treatments. Patients regain sound performance without systemic organ toxicity, sparing handlers the financial and emotional stress of complicated surgeries. Adopting high-performance laser technology equips modern veterinary facilities with a reliable, evidence-backed treatment foundation that preserves long-term athletic soundness and enhances patient quality of life.<\/p>","protected":false},"excerpt":{"rendered":"<p>Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"slim_seo":{"title":"Deep Canine Lumbosacral Stenosis Laser Solutions","description":"Resolve canine degenerative lumbosacral stenosis and cauda equina pain using dual-wavelength Class IV laser therapy engineered for deep tissue recovery."},"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"","_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[19],"tags":[845,815,847,840,841],"class_list":["post-17596","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-canine-laser-therapy","tag-laser-therapy-machine","tag-equine-laser-therapy","tag-veterinary-laser-therapy","tag-vet-laser-therapy"],"metadata":{"_edit_lock":["1788415812:1"],"_edit_last":["1"],"_aioseo_title":[null],"_aioseo_description":[null],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"catce":["sidebar-widgets4"],"slim_seo":["a:2:{s:5:\"title\";s:48:\"Deep Canine Lumbosacral Stenosis Laser Solutions\";s:11:\"description\";s:152:\"Resolve canine degenerative lumbosacral stenosis and cauda equina pain using dual-wavelength Class IV laser therapy engineered for deep tissue recovery.\";}"],"_wp_old_date":["2026-09-13"],"views":["58"],"wpil_links_inbound_internal_count":["1"],"wpil_links_inbound_internal_count_data":["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"],"wpil_links_outbound_internal_count":["1"],"wpil_links_outbound_internal_count_data":["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"],"wpil_links_outbound_external_count":["0"],"wpil_links_outbound_external_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_sync_report3":["1"],"wpil_sync_report2_time":["2026-09-16T07:35:44+00:00"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix\" \/>\n\t\t<meta property=\"og:description\" content=\"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-09-13T11:30:02+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-13T11:30:02+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#blogposting\",\"name\":\"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix\",\"headline\":\"Multi Band Photons Resolve Canine Lumbosacral Stenosis\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/laser-therapy-for-dogs247.jpg\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html\\\/#articleImage\",\"width\":395,\"height\":373,\"caption\":\"Laser therapy for dogs247\"},\"datePublished\":\"2026-09-13T19:30:02+08:00\",\"dateModified\":\"2026-09-13T19:30:02+08:00\",\"inLanguage\":\"it-IT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#webpage\"},\"articleSection\":\"Industry News, Canine Laser Therapy, Laser Therapy Machine, Equine Laser Therapy, Veterinary Laser Therapy, Vet Laser Therapy\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/it\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#listItem\",\"name\":\"Multi Band Photons Resolve Canine Lumbosacral Stenosis\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#listItem\",\"position\":4,\"name\":\"Multi Band Photons Resolve Canine Lumbosacral Stenosis\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/categoria\\\/notizie\\\/industry-news#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html\",\"name\":\"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix\",\"description\":\"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian\",\"inLanguage\":\"it-IT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/author\\\/fengmaiadmin#author\"},\"datePublished\":\"2026-09-13T19:30:02+08:00\",\"dateModified\":\"2026-09-13T19:30:02+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"it-IT\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/it\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix","description":"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian","canonical_url":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#blogposting","name":"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix","headline":"Multi Band Photons Resolve Canine Lumbosacral Stenosis","author":{"@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/it\/#person"},"image":{"@type":"ImageObject","url":"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/09\/laser-therapy-for-dogs247.jpg","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html\/#articleImage","width":395,"height":373,"caption":"Laser therapy for dogs247"},"datePublished":"2026-09-13T19:30:02+08:00","dateModified":"2026-09-13T19:30:02+08:00","inLanguage":"it-IT","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#webpage"},"articleSection":"Industry News, Canine Laser Therapy, Laser Therapy Machine, Equine Laser Therapy, Veterinary Laser Therapy, Vet Laser Therapy"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/it","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/it\/categoria\/notizie","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#listItem","name":"Multi Band Photons Resolve Canine Lumbosacral Stenosis"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#listItem","position":4,"name":"Multi Band Photons Resolve Canine Lumbosacral Stenosis","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin#author","url":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#webpage","url":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html","name":"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix","description":"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian","inLanguage":"it-IT","isPartOf":{"@id":"https:\/\/fotonmedix.com\/it\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/it\/author\/fengmaiadmin#author"},"datePublished":"2026-09-13T19:30:02+08:00","dateModified":"2026-09-13T19:30:02+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/it\/#website","url":"https:\/\/fotonmedix.com\/it\/","name":"FotonMedix","inLanguage":"it-IT","publisher":{"@id":"https:\/\/fotonmedix.com\/it\/#person"}}]},"og:locale":"it_IT","og:site_name":"FotonMedix |","og:type":"article","og:title":"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix","og:description":"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian","og:url":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html","article:published_time":"2026-09-13T11:30:02+00:00","article:modified_time":"2026-09-13T11:30:02+00:00","twitter:card":"summary_large_image","twitter:title":"Multi Band Photons Resolve Canine Lumbosacral Stenosis | FotonMedix","twitter:description":"Dual-spectrum Class IV emission delivers direct cauda equina photon saturation, pairs microvascular reperfusion with compressive epidural edema evacuation, and suppresses dermal thermal spikes through millisecond pulse duty gating. Small animal orthopedic surgeons and canine rehabilitation specialists consistently encounter severe clinical stagnation when treating degenerate lumbosacral stenosis (cauda equina syndrome) in working breeds. An eight-year-old Belgian"},"aioseo_meta_data":{"post_id":"17596","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":null,"breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-09-03 06:10:09","updated":"2026-09-13 12:18:12","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/it\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/it\/categoria\/notizie\" title=\"News\">News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news\" title=\"Industry News\">Industry News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tMulti Band Photons Resolve Canine Lumbosacral Stenosis\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/it"},{"label":"News","link":"https:\/\/fotonmedix.com\/it\/categoria\/notizie"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/it\/categoria\/notizie\/industry-news"},{"label":"Multi Band Photons Resolve Canine Lumbosacral Stenosis","link":"https:\/\/fotonmedix.com\/it\/multi-band-photons-resolve-canine-lumbosacral-stenosis.html"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts\/17596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/comments?post=17596"}],"version-history":[{"count":3,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts\/17596\/revisions"}],"predecessor-version":[{"id":18690,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/posts\/17596\/revisions\/18690"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/media?parent=17596"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/categories?post=17596"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/it\/wp-json\/wp\/v2\/tags?post=17596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}