{"id":12973,"date":"2026-04-17T10:24:00","date_gmt":"2026-04-17T02:24:00","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-04-14T15:57:35","modified_gmt":"2026-04-14T07:57:35","slug":"precision-photomedicine-optimizing-mitochondrial-signaling-with-high-fluence-laser-integration","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/ja\/precision-photomedicine-optimizing-mitochondrial-signaling-with-high-fluence-laser-integration.html\/","title":{"rendered":"\u7cbe\u5bc6\u5149\u533b\u7642\uff1a\u9ad8\u30d5\u30eb\u30a8\u30f3\u30b9\u30ec\u30fc\u30b6\u30fc\u7d71\u5408\u306b\u3088\u308b\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u30b7\u30b0\u30ca\u30eb\u306e\u6700\u9069\u5316"},"content":{"rendered":"<p>\u73fe\u4ee3\u306e\u30ea\u30cf\u30d3\u30ea\u30c6\u30fc\u30b7\u30e7\u30f3\u533b\u7642\u3067\u306f\u3001\u7de9\u548c\u30b1\u30a2\u304b\u3089\u518d\u751f\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u3078\u306e\u79fb\u884c\u304c\u3001\u591a\u6ce2\u9577\u5149\u5b50\u306e\u6b63\u78ba\u306a\u5fdc\u7528\u306b\u3088\u3063\u3066\u63a8\u9032\u3055\u308c\u3066\u3044\u308b\u3002 <strong>\u9ad8\u51fa\u529b\u30ec\u30fc\u30b6\u30fc\u6cbb\u7642<\/strong> \u306f\u30b7\u30c8\u30af\u30ed\u30e0c\u30aa\u30ad\u30b7\u30c0\u30fc\u30bc\u9175\u7d20\u3092\u8abf\u7bc0\u3057\u3066ATP\u5408\u6210\u3092\u4fc3\u9032\u3057\u3001\u6162\u6027\u708e\u75c7\u30ab\u30b9\u30b1\u30fc\u30c9\u3092\u89e3\u6d88\u3059\u308b\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30d0\u30a4\u30aa\u30a8\u30ca\u30b8\u30a7\u30c6\u30a3\u30c3\u30af\u30fb\u30d5\u30ed\u30f3\u30c6\u30a3\u30a2\uff1a\u6df1\u5ea6\u3068\u7dda\u91cf\u306e\u6bd4\u3092\u89e3\u304f<\/h2>\n\n\n\n<p>For clinical directors overseeing sports medicine or physical therapy departments, the fundamental technical challenge lies in the &#8220;Depth of Penetration&#8221; vs. &#8220;Effective Therapeutic Dose.&#8221; While a standard <strong>\u8d64\u8272\u5149\u30ec\u30fc\u30b6\u30fc\u6cbb\u7642\u5668<\/strong> \u306f\u8868\u9762\u7684\u306a\u5229\u70b9\u3092\u63d0\u4f9b\u3059\u308b\u304b\u3082\u3057\u308c\u306a\u3044\u304c\u30015cm\u304b\u308910cm\u306e\u6df1\u3055\u3067\u6cbb\u7642\u7528\u653e\u5c04\u7167\u5ea6\u3092\u9054\u6210\u3059\u308b\u306b\u306f\u3001\u30d2\u30c8\u306e\u8102\u80aa\u7d44\u7e54\u3068\u7b4b\u8089\u7d44\u7e54\u306b\u304a\u3051\u308b\u6563\u4e71\u4fc2\u6570\uff08$\u306e\u975e\u5bfe\u79f0\u6027\uff09\u3092\u9ad8\u5ea6\u306b\u7406\u89e3\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3002.<\/p>\n\n\n\n<p>\u3092\u5206\u6790\u3059\u308b\u3002 <strong>\u30ec\u30fc\u30b6\u30fc\u6cbb\u7642\u5668 \u4fa1\u683c<\/strong>, professionals must evaluate the system&#8217;s ability to maintain beam collimation. High-end systems like the LaserMedix 3000U5 utilize a &#8220;Top-Hat&#8221; beam profile, ensuring uniform energy distribution across the treatment area. This prevents &#8220;hot spots&#8221; that cause surface thermal discomfort while ensuring the target deep tissue reaches the required threshold of $6-10 J\/cm^2$.<\/p>\n\n\n\n<p>The quantum efficiency of this process is tied to the mitochondrial absorption spectrum. The rate of photo-dissociation of Nitric Oxide (NO) from Cytochrome c Oxidase ($CcO$)\u2014a critical step in restoring cellular respiration\u2014is wavelength-dependent. We can model the photon density requirement ($\\phi$) using the following transport equation:<\/p>\n\n\n\n<p>$$\\frac{1}{c} \\frac{\\partial \\Phi(\\mathbf{r}, t)}{\\partial t} &#8211; D \\nabla^2 \\Phi(\\mathbf{r}, t) + \\mu_a \\Phi(\\mathbf{r}, t) = S(\\mathbf{r}, t)$$<\/p>\n\n\n\n<p>\u3053\u3053\u3067\u3001$D$\u306f\u62e1\u6563\u4fc2\u6570\u3001$S$\u306f\u30bd\u30fc\u30b9\u9805\u3067\u3042\u308b\u3002\u81e8\u5e8a\u533b\u306b\u3068\u3063\u3066\u3001\u3053\u308c\u306f\u4ee5\u4e0b\u3092\u610f\u5473\u3059\u308b\u3002 <strong>\u30ec\u30fc\u30b6\u30fc\u6cbb\u7642\u5668<\/strong> must deliver high peak power to overcome the &#8220;optical barrier&#8221; of the dermis, ensuring that a sufficient number of photons reach the hypoxic cells to trigger the transition from the $M1$ (pro-inflammatory) to the $M2$ (anti-inflammatory) macrophage phenotype.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"374\" src=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/deep-tissue-laser-therapy43.jpg\" alt=\"\" class=\"wp-image-12974\" srcset=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/deep-tissue-laser-therapy43.jpg 400w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/deep-tissue-laser-therapy43-300x281.jpg 300w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/04\/deep-tissue-laser-therapy43-13x12.jpg 13w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">\u81e8\u5e8a\u7684\u6709\u52b9\u6027\uff1a\u30af\u30e9\u30b94\u30c0\u30a4\u30aa\u30fc\u30c9\u30b7\u30b9\u30c6\u30e0\u3068\u5f93\u6765\u306e\u6cbb\u7642\u6cd5\u306e\u6bd4\u8f03<\/h2>\n\n\n\n<p>B2B procurement decisions in the medical sector are increasingly based on &#8220;Time-to-Resolution&#8221; metrics. The ability of the VetMedix and LaserMedix series to deliver 15W to 30W of continuous or pulsed power fundamentally alters the clinical workflow compared to Low-Level Laser Therapy (LLLT) or ultrasound.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>\u81e8\u5e8a\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc<\/strong><\/td><td><strong>\u5f93\u6765\u306eLLLT\uff08\u30af\u30e9\u30b93b\uff09<\/strong><\/td><td><strong>Fotonmedix \u30af\u30e9\u30b94\u30b7\u30b9\u30c6\u30e0<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>\u30d1\u30ef\u30fc\u5bc6\u5ea6<\/strong><\/td><td>$&lt; 0.5\u30ef\u30c3\u30c8$<\/td><td>$15W &#8211; 45W$<\/td><\/tr><tr><td><strong>\u6cbb\u7642\u6642\u9593\uff0810k\u30b8\u30e5\u30fc\u30eb\uff09<\/strong><\/td><td>$&gt;330\u5206$<\/td><td>$11\u5206$\uff0815W\u6642\uff09<\/td><\/tr><tr><td><strong>\u30d0\u30a4\u30aa\u523a\u6fc0\u6df1\u5ea6<\/strong><\/td><td>$0.5cm &#8211; 1.0cm$<\/td><td>\u6700\u5927$12cm$<\/td><\/tr><tr><td><strong>\u30b5\u30fc\u30de\u30eb\u30fb\u30e2\u30b8\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3<\/strong><\/td><td>\u306a\u3057\uff08\u30b5\u30fc\u30de\u30eb\uff09<\/td><td>\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff08\u30a6\u30a9\u30fc\u30e0\u30bd\u30fc\u30af\u52b9\u679c\uff09<\/td><\/tr><tr><td><strong>\u60a3\u8005\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8<\/strong><\/td><td>1\uff5e2\u4eba\/\u6642\u9593<\/td><td>4\uff5e6\u4eba\/\u6642\u9593<\/td><\/tr><tr><td><strong>\u81e8\u5e8a\u9069\u5fdc<\/strong><\/td><td>\u8868\u5728\u6027\u306e\u5275\u50b7\u306e\u307f<\/td><td>\u6df1\u90e8\u795e\u7d4c\u969c\u5bb3, \u810a\u690e\u75c5\u7406<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b1\u30fc\u30b9\u30b9\u30bf\u30c7\u30a3\u30b0\u30ec\u30fc\u30c9\u2161\u306e\u5185\u5074\u5074\u526f\u976d\u5e2f\uff08MCL\uff09\u65ad\u88c2\u306e\u6cbb\u7642<\/h2>\n\n\n\n<p><strong>\u60a3\u8005\u306e\u80cc\u666f<\/strong> A 29-year-old professional rugby player sustained a Grade II MCL tear during competition. Significant joint laxity, localized edema, and inability to bear weight. Traditional prognosis suggested 6\u20138 weeks for return to play.<\/p>\n\n\n\n<p><strong>\u6700\u521d\u306e\u8a3a\u65ad<\/strong> MRI\u3067MCL\u306e\u90e8\u5206\u65ad\u88c2\u304c\u78ba\u8a8d\u3055\u308c\u3001\u75c5\u5de3\u5468\u56f2\u306e\u6d6e\u816b\u3068\u95a2\u7bc0\u5185\u6db2\u8caf\u7559\u304c\u8457\u660e\u3067\u3042\u3063\u305f\u3002\u75bc\u75db\u30b9\u30b3\u30a2\uff08VAS\uff09\u306f9\/10\u3002.<\/p>\n\n\n\n<p><strong>\u6cbb\u7642\u30d7\u30ed\u30c8\u30b3\u30eb\uff08LaserMedix 3000U5\uff09\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6ce2\u9577\u30b7\u30ca\u30b8\u30fc\uff1a<\/strong> 810nm (\u9178\u7d20\u5316) + 980nm (\u75db\u307f\u6291\u5236) + 1064nm (\u6df1\u90e8\u69cb\u9020\u4fee\u5fa9)\u3002.<\/li>\n\n\n\n<li><strong>\u30e2\u30fc\u30c9\u3060\uff1a<\/strong> \u30b9\u30fc\u30d1\u30fc\u30d1\u30eb\u30b9\uff08\u71b1\u7de9\u548c\u3092\u53ef\u80fd\u306b\u3057\u306a\u304c\u3089\u30d4\u30fc\u30af\u30d1\u30ef\u30fc\u3092\u6700\u5927\u5316\u3059\u308b\uff09\u3002.<\/li>\n\n\n\n<li><strong>\u983b\u5ea6\uff1a<\/strong> \u6700\u521d\u306e5\u65e5\u9593\u306f\u6bce\u65e5\u3001\u305d\u306e\u5f8c\u306f\u90313\u56de\u3002.<\/li>\n\n\n\n<li><strong>\u6295\u4e0e\u91cf\uff1a<\/strong> $15 J\/cm^2$\u3092\u976d\u5e2f\u633f\u5165\u70b9\u4e0a\u30671\u56de\u3042\u305f\u308a\u3002.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u56de\u5fa9\u306e\u30bf\u30a4\u30e0\u30e9\u30a4\u30f3<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>3\u65e5\u76ee<\/strong> \u6d6e\u816b\u306f50%\u306b\u3088\u308a\u8efd\u6e1b\u3057\u305f\u3002\u60a3\u8005\u306fVAS 4\/10\u3068\u5831\u544a\u3057\u305f\u3002.<\/li>\n\n\n\n<li><strong>10\u65e5\u76ee<\/strong> Joint stability improved significantly. Range of motion (ROM) increased from 45\u00b0 to 110\u00b0.<\/li>\n\n\n\n<li><strong>21\u65e5\u76ee<\/strong> \u30d5\u30a9\u30ed\u30fc\u30a2\u30c3\u30d7\u306e\u8d85\u97f3\u6ce2\u691c\u67fb\u3067\u306f\u3001\u30b3\u30e9\u30fc\u30b2\u30f3\u7dda\u7dad\u306e\u914d\u5217\u304c\u9032\u307f\u3001\u6b8b\u5b58\u6db2\u306f\u6700\u5c0f\u9650\u3067\u3042\u3063\u305f\u3002.<\/li>\n\n\n\n<li><strong>28\u65e5\u76ee\uff08\u7d50\u8ad6\uff09\uff1a<\/strong> Patient cleared for non-contact training\u20143 weeks ahead of the standard clinical timeline.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u30a8\u30cd\u30eb\u30ae\u30fc\u4f9b\u7d66\u30d1\u30e9\u30e1\u30fc\u30bf\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>\u30d5\u30a7\u30fc\u30ba<\/strong><\/td><td><strong>\u671f\u9593<\/strong><\/td><td><strong>\u6ce2\u9577 (nm)<\/strong><\/td><td><strong>\u30d4\u30fc\u30af\u51fa\u529b (W)<\/strong><\/td><td><strong>\u5e73\u5747\u51fa\u529b (W)<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>\u93ae\u75db\u671f<\/strong><\/td><td>4\u5206<\/td><td>980<\/td><td>30W<\/td><td>10W<\/td><\/tr><tr><td><strong>\u4fee\u7406\u6bb5\u968e<\/strong><\/td><td>8\u5206<\/td><td>810 \/ 1064<\/td><td>25W<\/td><td>15W<\/td><\/tr><tr><td><strong>\u30ea\u30f3\u30d1\u30c9\u30ec\u30ca\u30fc\u30b8\u30e5<\/strong><\/td><td>3\u5206<\/td><td>650<\/td><td>2W<\/td><td>2W<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3068\u904b\u7528\u5bff\u547d\uff1aB2B\u4fe1\u983c\u6027\u57fa\u6e96<\/h2>\n\n\n\n<p>\u30af\u30ea\u30cb\u30c3\u30af\u3084\u5730\u57df\u306e\u8ca9\u58f2\u4ee3\u7406\u5e97\u306b\u3068\u3063\u3066\u3001\u305d\u306e\u8010\u4e45\u6027\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3042\u308b\u3002 <strong>\u30ec\u30fc\u30b6\u30fc\u6cbb\u7642\u5668<\/strong> is as critical as their clinical performance. Our engineering focus centers on &#8220;Diode Integrity&#8221; and &#8220;Optical Path Protection.&#8221;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u9ad8\u5ea6\u306a\u5185\u90e8\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3<\/h3>\n\n\n\n<p>\u3059\u3079\u3066\u306eFotonmedix\u30c7\u30d0\u30a4\u30b9\u306b\u306f\u3001\u8d77\u52d5\u6642\u306b\u81ea\u5df1\u6821\u6b63\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3046\u5185\u8535\u30d1\u30ef\u30fc\u30e1\u30fc\u30bf\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a <strong>\u7b2c4\u7a2e\u30ec\u30fc\u30b6\u30fc\u6cbb\u7642\u5668<\/strong> maintains a linear output. If the diode\u2019s efficiency drops due to environmental heat stress, the system\u2019s intelligent &#8220;Auto-Compensation&#8221; algorithm adjusts the current to maintain the user-defined Wattage, preventing under-dosing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u4eba\u9593\u5de5\u5b66\u3068\u30d5\u30a1\u30a4\u30d0\u30fc\u30fb\u30de\u30cd\u30b8\u30e1\u30f3\u30c8<\/h3>\n\n\n\n<p>In the busy environment of a private practice, handpiece durability is a common pain point. Our therapeutic handpieces utilize &#8220;Military-Grade&#8221; armored cables that protect the delicate quartz fibers from micro-fractures during frequent movement. Furthermore, the quick-change lens system allows practitioners to switch from a 10mm spot size for trigger points to a 30mm spot size for large muscle groups (like the quadriceps) in seconds, maximizing the utility of the <strong>\u30d7\u30ed\u30d5\u30a7\u30c3\u30b7\u30e7\u30ca\u30eb\u533b\u7642\u30ec\u30fc\u30b6\u30fc\u30b7\u30b9\u30c6\u30e0<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u3088\u304f\u3042\u308b\u8cea\u554f\u30d7\u30ed\u30d5\u30a7\u30c3\u30b7\u30e7\u30ca\u30eb\u30fb\u30a4\u30f3\u30c6\u30b0\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u305f\u3081\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30fb\u30ac\u30a4\u30c0\u30f3\u30b9<\/h2>\n\n\n\n<p><strong>Q: 1064nm\u306e\u6ce2\u9577\u306f\u3001\u7279\u306b\u6df1\u90e8\u306e\u7b4b\u9aa8\u683c\u7cfb\u306e\u4fee\u5fa9\u306b\u3069\u306e\u3088\u3046\u306b\u5f79\u7acb\u3061\u307e\u3059\u304b\uff1f<\/strong><\/p>\n\n\n\n<p>A: 1064nm has the lowest absorption in melanin and water, allowing it to bypass the skin&#8217;s surface more efficiently than shorter wavelengths. This makes it the &#8220;gold standard&#8221; for treating deep-seated pathologies like hip bursitis or lower back disc herniations.<\/p>\n\n\n\n<p><strong>Q:\u30af\u30e9\u30b94\u30ec\u30fc\u30b6\u30fc\u3067\u767a\u751f\u3059\u308b\u71b1\u306f\u3001\u8853\u5f8c\u306e\u30a4\u30f3\u30d7\u30e9\u30f3\u30c8\u306b\u5b89\u5168\u3067\u3059\u304b\uff1f<\/strong><\/p>\n\n\n\n<p>A: Yes, provided the &#8220;Scanning Technique&#8221; is used. Unlike ultrasound, which can cause &#8220;standing waves&#8221; and heat metal implants rapidly, laser energy is absorbed primarily by chromophores in the tissue. The heat generated is a secondary effect of the metabolic surge and is generally safe around orthopedic hardware.<\/p>\n\n\n\n<p><strong>Q: HorseVet\u30b7\u30ea\u30fc\u30ba\u3068\u4eba\u9593\u306eLaserMedix\u30b7\u30ea\u30fc\u30ba\u306e\u4e3b\u306a\u9055\u3044\u306f\u4f55\u3067\u3059\u304b\uff1f<\/strong><\/p>\n\n\n\n<p>A: The difference lies in the &#8220;Optical Power Density.&#8221; Equine skin and coat absorb more energy at the surface. The HorseVet 3000U5 is calibrated with a higher power floor to ensure that despite the hair-coat interference, the underlying tendons receive a therapeutic dose equivalent to human protocols.<\/p>","protected":false},"excerpt":{"rendered":"<p>In the landscape of modern rehabilitative medicine, the transition from palliative care to regenerative protocols is driven by the precise application of multi-wavelength photons, where high power laser therapy modulates the cytochrome c oxidase enzyme to accelerate ATP synthesis and resolve chronic inflammatory cascades. The Bio-Energetic Frontier: Solving the Depth-to-Dose Ratio For clinical directors overseeing sports medicine or physical therapy departments, the fundamental technical challenge lies in the &#8220;Depth of Penetration&#8221; vs. &#8220;Effective Therapeutic Dose.&#8221; While a standard red light laser therapy machine might offer superficial benefits, achieving therapeutic irradiance at depths of 5cm to 10cm requires a sophisticated understanding of the scattering coefficient ($\\mu_s$) in human adipose and muscle [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":"","_wpscp_schedule_draft_date":"","_wpscp_schedule_republish_date":"","_wpscppro_advance_schedule":false,"_wpscppro_advance_schedule_date":"","_wpscppro_dont_share_socialmedia":false,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"default","_instagram_share_type":"default","_medium_share_type":"default","_threads_share_type":"default","_google_business_share_type":"default","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[19],"tags":[815,863,817,820],"class_list":["post-12973","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-laser-therapy-machine","tag-laser-therapy-machine-price","tag-class-4-laser-therapy","tag-high-power-laser-therapy"],"metadata":{"_facebook_share_type":["default"],"_twitter_share_type":["default"],"_linkedin_share_type":["default"],"_pinterest_share_type":["default"],"_instagram_share_type":["default"],"_medium_share_type":["default"],"_threads_share_type":["default"],"_google_business_share_type":["default"],"_wpsp_custom_templates":["a:7:{s:8:\"facebook\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:7:\"twitter\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:8:\"linkedin\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:9:\"pinterest\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:9:\"instagram\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:6:\"medium\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:7:\"threads\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}}"],"_edit_lock":["1776153501:1"],"_wpsp_social_scheduling":["a:11:{s:7:\"enabled\";b:0;s:8:\"datetime\";N;s:9:\"platforms\";a:0:{}s:6:\"status\";s:13:\"template_only\";s:10:\"dateOption\";s:5:\"today\";s:10:\"timeOption\";s:3:\"now\";s:10:\"customDays\";s:0:\"\";s:11:\"customHours\";s:0:\"\";s:10:\"customDate\";s:0:\"\";s:10:\"customTime\";s:0:\"\";s:14:\"schedulingType\";s:8:\"absolute\";}"],"wpil_sync_report3":["1"],"themepark_post_bcolor":["#f5f5f5"],"themepark_post_width":["1022px"],"themepark_post_img":[""],"themepark_post_img_po":["left"],"themepark_post_img_re":[""],"themepark_post_img_cover":[""],"themepark_post_img_fixed":[""],"themepark_post_hide_title":[""],"themepark_post_main_b":[""],"themepark_post_main_p":["100"],"themepark_paddingblock":[""],"footnotes":[""],"_wpscp_schedule_draft_date":[""],"_wpscp_schedule_republish_date":[""],"_wpscppro_advance_schedule_date":[""],"_wpscppro_dont_share_socialmedia":[""],"_wpscppro_custom_social_share_image":["0"],"_linkedin_share_type_page":["default"],"_selected_social_profile":["a:0:{}"],"_wpsp_enable_custom_social_template":[""],"_wpsp_active_default_template":["1"],"_edit_last":["1"],"_aioseo_title":["High Power Laser Therapy Machine Price &amp; 1064nm Clinical Efficacy"],"_aioseo_description":["Technical guide on Class 4 laser therapy machines for deep tissue repair. Analyze 1064nm penetration, ROI for clinics, and clinical cases in sports medicine."],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"catce":["sidebar-widgets4"],"views":["11"]},"aioseo_notices":[],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/posts\/12973","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/comments?post=12973"}],"version-history":[{"count":1,"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/posts\/12973\/revisions"}],"predecessor-version":[{"id":12975,"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/posts\/12973\/revisions\/12975"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/media?parent=12973"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/categories?post=12973"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/ja\/wp-json\/wp\/v2\/tags?post=12973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}