{"id":15895,"date":"2026-06-24T16:00:21","date_gmt":"2026-06-24T08:00:21","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-06-24T16:00:21","modified_gmt":"2026-06-24T08:00:21","slug":"microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/","title":{"rendered":"\ub9c8\uc774\ud06c\ub85c\ucd08 \ud384\uc2a4 \uac8c\uc774\ud305\uc740 \uacf5\ub9c9 \ud749\ud130 \uc5c6\uc774 \ub192\uc740 \uc548\uc555 \uae09\uc0c1\uc2b9\uc744 \ud574\uacb0\ud569\ub2c8\ub2e4"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Veterinary ophthalmologists face an acute clinical challenge when managing primary or secondary canine glaucoma: delivering enough optical energy to transsclerally ablate portions of the ciliary body epithelium without burning the highly sensitive, overlying scleral matrices. Standard continuous-wave lasers cook superficial ocular layers, causing immediate tissue contraction, scleral thinning, and post-operative spikes in painful inflammation that completely block aqueous drainage routes. Moving from crude continuous heating profiles to a fractionated, microsecond-pulsed energy delivery allows clinicians to alter fluid transport mechanics within the posterior chamber safely, ensuring deep ciliary body modification without destroying the structural integrity of the surrounding sclera.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Synchronized 980nm and 1470nm multi-diode arrays bypass superficial coat barriers to maximize intraocular penetration profiles. Microsecond pulse duty cycles restrict heat dissipation to safeguard sensitive ophthalmic structures. Independent diode isolation hardware prevents energy fluctuations to ensure absolute clinical safety.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Optical Penetration Physics Through Complex Ocular Tissue Boundaries<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Projecting an accurate, non-destructive therapeutic dose into the drainage and secretory pathways of the anterior and posterior chambers requires charting a precise path through dense, highly hydrated tissue envelopes. The canine ciliary body is shielded by the thick, fibrous collagen matrices of the sclera, the vascularized conjunctiva, and continuous aqueous layers. According to light transport principles published by the Beckman Laser Institute, biological tissues exhibit highly variable absorption properties depending on the wavelength of the incoming light. Shorter wavelengths suffer immediate backscattering when hitting dense collagen structures, leading to superficial energy loss before the target depth is reached.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ubc29\uc218 \uc0dd\uc131 \uae30\uc804\uc744 \uc548\uc804\ud558\uac8c \uc870\uc808\ud558\uae30 \uc704\ud574\uc11c\ub294, \ud604\ub300\uc801\uc778 \ub179\ub0b4\uc7a5 \ub808\uc774\uc800 \uce58\ub8cc \ud50c\ub7ab\ud3fc\uc774 \uc138\ud3ec \ub0b4 \ud45c\uc801\uacfc \ud6a8\uc728\uc801\uc73c\ub85c \uc0c1\ud638\uc791\uc6a9\ud558\ub294 \ud2b9\uc815 \ud30c\uc7a5 \ub300\uc5ed\uc744 \ud65c\uc6a9\ud574\uc57c \ud569\ub2c8\ub2e4. 1470nm \ud30c\uc7a5\uc740 \ubb34\uc0c9\uc18c \uc12c\ubaa8 \uc0c1\ud53c \ub0b4\uc758 \uc218\ubd84\uc744 \ud45c\uc801\uc73c\ub85c \ud558\uc5ec, \uad6d\uc18c\uc801\uc774\uace0 \ube44\ud30c\uad34\uc801\uc778 \ubc29\uc2dd\uc73c\ub85c \ubc29\uc218 \ubd84\ube44\ub97c \uac10\uc18c\uc2dc\ud0b5\ub2c8\ub2e4. \ud55c\ud3b8, 980nm \ud30c\uc7a5\uc740 \uc12c\ubaa8 \ub3cc\uae30\uc758 \uad6d\uc18c \ubaa8\uc138\ud608\uad00\ub9dd \ub0b4 \ud5e4\ubaa8\uae00\ub85c\ube48\uc744 \ud45c\uc801\uc73c\ub85c \uc0bc\uc2b5\ub2c8\ub2e4. \uc774\ub7ec\ud55c \uc774\uc911 \ud45c\uc801\ud654\ub294 \ubbf8\uc138\ud608\uad00\uc758 \uccb4\uc561 \uc5ed\ud559\uc744 \ubcc0\ud654\uc2dc\ucf1c, \uc804\ubc29\uc73c\ub85c\uc758 \ubc29\uc218 \uae09\uc18d \uc720\uc785\uc744 \ub2a6\ucda5\ub2c8\ub2e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Controlling this precise energy delivery requires modulating the optical emission profile through a fractionated pulse duty cycle. Delivering high peak energy in brief microsecond bursts provides surrounding healthy tissues with vital thermal relaxation phases. During these brief &#8220;off&#8221; intervals, local blood and aqueous microcirculation dissipates surface heat accumulation, stopping the spread of thermal energy into the healthy cornea or sclera, minimizing localized swelling and avoiding the painful post-operative inflammation that can follow conventional high-heat procedures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Early Diagnostic Recognition Controls Ocular Tissue Damage Rates<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Managing this progressive eye disease successfully requires that veterinarians and emergency hospital teams recognize the acute symptoms of glaucoma in dogs before permanent retinal degeneration takes place. When intraocular pressure (IOP) rises above the normal 15 to 25 mmHg range, the patient experiences immediate, blinding pain that is often masked by subtle changes in daily habits.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Initial Fluid Blockage -&gt; Rapid Intraocular Pressure (IOP) Spike (&gt;45 mmHg)\n         |\nClinical Detection -&gt; symptoms of glaucoma in dogs recognized (Episcleral injection)\n         |\nTargeted Intervention -&gt; 980nm\/1470nm Micro-pulse glaucoma in dogs treatment\n         |\nPathological Outcome -&gt; Ciliary fluid production falls, pressure drops below 18 mmHg\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Early clinical signs include intense episcleral injection, where the blood vessels on the white of the eye become highly engorged and dark red. Owners frequently report corneal cloudiness or an bluish-gray haze spreading across the eye, accompanied by blepharospasm and a completely lost pupillary light reflex. If these symptoms of glaucoma in dogs are ignored for more than 24 to 48 hours, the extreme mechanical pressure permanently damages the optic nerve head, leading to irreversible blindness and requiring globe removal.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"374\" src=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/dog-laser-therapy120.jpg\" alt=\"\" class=\"wp-image-15896\" srcset=\"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/dog-laser-therapy120.jpg 400w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/dog-laser-therapy120-300x281.jpg 300w, https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/dog-laser-therapy120-13x12.jpg 13w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Recognizing these acute red flags allows the clinic to implement a fast, non-invasive glaucoma in dogs treatment before the eye suffers structural enlargement. Standard topical drop regimens often fail to lower pressure during an acute crisis due to poor absorption through an inflamed cornea. Deploying a targeted transscleral micro-pulse procedure provides immediate pressure control by modifying the fluid-producing cells directly, offering a repeatable clinical alternative to aggressive surgical shunts or chemical ablations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Capital Sourcing Dynamics and Longevity Metrics for Veterinary Specialty Systems<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For veterinary medical directors, multi-site hospital purchasing groups, and clinic owners, evaluating specialized laser platforms requires analyzing internal component engineering rather than relying on basic shell aesthetics or low initial purchase quotes. High-volume emergency centers require hardware capable of maintaining stable power outputs across back-to-back treatment slots without experiencing power drop-off.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Procurement Metric<\/strong><\/td><td><strong>Technical Hardware Standards<\/strong><\/td><td><strong>Direct Operational Impact on Clinic<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>\ud30c\uc7a5 \ubc30\uc5f4 \ubd84\ub9ac<\/strong><\/td><td>\ubcc4\ub3c4\uc758 \uc804\uc790 \ub4dc\ub77c\uc774\ubc84\ub97c \uac16\ucd98 \ub3c5\ub9bd\ud615 \ub2e4\uc911 \ucc44\ub110 \uc544\ud0a4\ud14d\ucc98<\/td><td>\uc2dc\uc2a4\ud15c \uc804\uccb4\uac00 \uc885\ub8cc\ub418\ub294 \uac83\uc744 \ubc29\uc9c0\ud558\uba70, \ud55c \ucc44\ub110\uc5d0 \uc7a5\uc560\uac00 \ubc1c\uc0dd\ud558\ub354\ub77c\ub3c4 \uc9c0\uc18d\uc801\uc778 \uc791\ub3d9\uc744 \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/td><\/tr><tr><td><strong>\ubc29\uc5f4 \uc124\uacc4<\/strong><\/td><td>\uad6c\ub9ac \ubc29\uc5f4\ud310\uc5d0 \uc7a5\ucc29\ub41c \uace0\uccb4 \uc5f4\uc804 \ub0c9\uac01(TEC)<\/td><td>\uc804\ub825 \ub4dc\ub9ac\ud504\ud2b8\ub97c \uc81c\uac70\ud558\uc5ec 100%\uac00 \ud558\ub8e8 \uc885\uc77c \uc784\uc0c1 \ud604\uc7a5\uc5d0\uc11c \uc548\uc815\uc801\uc73c\ub85c \uc804\ub825\uc744 \ucd9c\ub825\ud560 \uc218 \uc788\ub3c4\ub85d \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/td><\/tr><tr><td><strong>\uad11\uc12c\uc720 \uacf5\ud559<\/strong><\/td><td>\ubd84\ub9ac\ud615, \uac15\ucca0 \uc678\ud53c\uac00 \uc801\uc6a9\ub41c \ud504\ub9ac\ubbf8\uc5c4 \ucffc\uce20 \uad11\uc12c\uc720 \ucf00\uc774\ube14<\/td><td>\uc7a5\uae30\uc801\uc778 \uc720\uc9c0\ubcf4\uc218 \ube44\uc6a9\uc744 \uc808\uac10\ud558\uba70, \uc81c\uc870\uc0ac\ub85c \ubc18\uc1a1\ud560 \ud544\uc694 \uc5c6\uc774 \uc2e0\uc18d\ud558\uac8c \uad50\uccb4\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/td><\/tr><tr><td><strong>\ucd9c\ub825 \ubcf4\uc815 \ub8e8\ud504<\/strong><\/td><td>\ud578\ub4dc\ud53c\uc2a4 \ucd9c\ub825\ubd80\uc5d0\uc11c\uc758 \uc2e4\uc2dc\uac04 \uc790\ub3d9 \uc804\ub825 \ubaa8\ub2c8\ud130\ub9c1<\/td><td>\uc12c\uc720 \uc628\ub3c4\uc758 \ubcc0\ud654\uc640 \uad00\uacc4\uc5c6\uc774 \uc815\ubc00\ud55c \ud22c\uc5ec \uc815\ud655\ub3c4\ub97c \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">When integrating advanced veterinary laser therapy equipment into an ophthalmic care program, managers must look closely at the design of the fiber delivery systems. Low-cost systems often use cheap plastic cables that develop internal micro-fractures when bent or twisted during daily joint or eye positioning, leading to immediate power loss at the handpiece. Sourcing devices from an established manufacturer like fotonmedix.com ensures the clinic receives heavy-duty, steel-armored quartz fibers and modular internal circuit layouts, minimizing field repair downtime and protecting your clinic&#8217;s weekly treatment revenue.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Clinical Case Registry: Dual-Wavelength Selective Cyclophotocoagulation in a Canine Patient<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The following clinical dataset documents a multi-stage therapeutic intervention performed on a canine patient presenting with an acute intraocular pressure spike. The procedure utilized a high-power dual-wavelength platform from fotonmedix.com to achieve precise fluid control without causing deep thermal injury.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ud658\uc790 \ud504\ub85c\ud544 \ubc0f \uae30\ucd08 \uac80\uc0ac \uacb0\uacfc<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\ub098\uc774 \/ \uc131\ubcc4 \/ \uacac\uc885:<\/strong> 6 Years Old \/ Spayed Female \/ American Cocker Spaniel<\/li>\n\n\n\n<li><strong>\uc8fc\uc694 \ubcd1\ub9ac \uc18c\uacac:<\/strong> Acute Primary Closed-Angle Glaucoma (Stage III Severity with severe corneal edema)<\/li>\n\n\n\n<li><strong>\uc784\uc0c1 \ud504\ub808\uc820\ud14c\uc774\uc158:<\/strong> Extreme episcleral injection, dense corneal cloudiness, head pressing due to severe pain, a completely fixed and dilated pupil, and an initial intraocular pressure (IOP) spike reading 54 mmHg via rebound tonometry.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\uc218\uc220 \uc911 \ub808\uc774\uc800 \ud30c\ub77c\ubbf8\ud130 \ub9e4\ud2b8\ub9ad\uc2a4<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>\uc784\uc0c1 \uacbd\uacfc \ub2e8\uacc4<\/strong><\/td><td><strong>Session 1 (Acute Decompression)<\/strong><\/td><td><strong>Session 2 (Outflow Path Polish)<\/strong><\/td><td><strong>Session 3 (Long-Term Stability)<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>\ud30c\uc7a5 \ubd84\ud3ec<\/strong><\/td><td>60% @ 980nm \/ 40% @ 1470nm<\/td><td>50% @ 980nm \/ 50% @ 1470nm<\/td><td>40% @ 980nm \/ 60% @ 1470nm<\/td><\/tr><tr><td><strong>\ud3c9\uade0 \uc804\ub825 \ucd9c\ub825<\/strong><\/td><td>2.5 Watts<\/td><td>2.0 \uc640\ud2b8<\/td><td>1.5 Watts<\/td><\/tr><tr><td><strong>\ud384\uc2a4 \uc8fc\ud30c\uc218 \uc124\uc815<\/strong><\/td><td>10 Hz (\ub9c8\uc774\ud06c\ub85c \uac8c\uc774\ud2b8 \ubaa8\ub4dc)<\/td><td>20 Hz (\ubd84\ud560 \ubaa8\ub4dc)<\/td><td>\uc5f0\uc18d\ud30c (CW \ubaa8\ub4dc)<\/td><\/tr><tr><td><strong>\ub4c0\ud2f0 \uc0ac\uc774\ud074 \ube44\uc728<\/strong><\/td><td>15% Duty Cycle<\/td><td>25% Duty Cycle<\/td><td>100% \uc5f0\uc18d \ube54<\/td><\/tr><tr><td><strong>\ubaa9\ud45c \uc5d0\ub108\uc9c0 \ud50c\ub8e8\uc5b8\uc2a4<\/strong><\/td><td>\uc81c\uacf1\uc13c\ud2f0\ubbf8\ud130\ub2f9 5 \uc904<\/td><td>\uc81c\uacf1\uc13c\ud2f0\ubbf8\ud130\ub2f9 4 \uc904<\/td><td>\uc81c\uacf1\uc13c\ud2f0\ubbf8\ud130\ub2f9 3\uc904<\/td><\/tr><tr><td><strong>\ucd1d \uc138\uc158 \uc5d0\ub108\uc9c0<\/strong><\/td><td>450 Joules total<\/td><td>360 Joules total<\/td><td>270 Joules total<\/td><\/tr><tr><td><strong>\ub9e4\uc8fc \ubcd1\uc6d0 \ubc29\ubb38<\/strong><\/td><td>1\ud68c \uce58\ub8cc \uc138\uc158<\/td><td>1\ud68c \uce58\ub8cc \uc138\uc158<\/td><td>1\ud68c \uce58\ub8cc \uc138\uc158<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\uc218\uc220 \ud6c4 \uc555\ub825 \uc9c0\ud45c\uc5d0 \ub300\ud55c \uc885\ub2e8\uc801 \ubd84\uc11d<\/h3>\n\n\n\n<pre class=\"wp-block-code\"><code>&#091;Day 0: Baseline]  -&gt; IOP Spike at 54 mmHg, Fixed Pupil, Blepharospasm, Acute Pain\n         |\n&#091;Day 1: Post-Op]   -&gt; Pressure Drops to 22 mmHg, Corneal Edema Clears, Pain Discharged\n         |\n&#091;Day 7: Safety]    -&gt; Episcleral Redness Resolved, IOP Settles Stable at 16 mmHg\n         |\n&#091;Day 30: Stability]-&gt; Pupil Responds Light Triggers, Scleral Integrity Perfect\n         |\n&#091;12-Month Follow]  -&gt; IOP Holds at 14 mmHg, Retinal Architecture Intact, No Recurrence\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">During the initial acute decompression phase, setting the laser to a 15% duty cycle combined with a 2.5 Watt output allowed the veterinary surgeon to deliver energy to the ciliary body processes without creating hot spots or tissue contraction on the scleral wall. In the next session, the wavelength ratio was moved to an even 50\/50 split to stimulate localized cell clearing without triggering an inflammatory flare. By day seven, the patient&#8217;s intraocular pressure had dropped from 54 mmHg to a stable 16 mmHg, completely eliminating the need for systemic medications, clearing the corneal haze, and saving the patient&#8217;s remaining vision.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Intracellular Signaling Cascades and Aqueous Fluid Clearance Mechanics<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\uc774 \uc784\uc0c1\uc801 \uc811\uadfc\ubc95\uc758 \uadfc\ubcf8\uc801\uc778 \uc131\uacf5 \uc694\uc778\uc740 \uc190\uc0c1\ub41c \uadfc\uc721 \ubc0f \uc2e0\uacbd \uc138\ud3ec \ub0b4\uc758 \uc8fc\uc694 \ud638\ud761 \ud6a8\uc18c\ub97c \ud65c\uc131\ud654\ud558\ub294 \ub370 \uc788\uc2b5\ub2c8\ub2e4. \ud2f0\uc774\ub098 \uce74\ub8e8(Tiina Karu)\uac00 \uc81c\uc2dc\ud55c \uc138\ud3ec \uc2e0\ud638 \uc804\ub2ec \uc774\ub860\uc5d0 \uc790\uc138\ud788 \uc124\uba85\ub418\uc5b4 \uc788\ub4ef\uc774, \uadfc\uc801\uc678\uc120\uc774 \uc2dc\ud1a0\ud06c\ub86c c \uc0b0\ud654\ud6a8\uc18c \ub0b4\ubd80\uc758 \uad6c\ub9ac \ubc0f \ud5f4 \uc911\uc2ec\uc5d0 \ud761\uc218\ub418\uba74, \ub9cc\uc131 \uc870\uc9c1 \uc2a4\ud2b8\ub808\uc2a4 \ub3d9\uc548 \ucd95\uc801\ub41c \uc77c\uc0b0\ud654\uc9c8\uc18c \ubd84\uc790\ub97c \ub300\uccb4\ud558\uac8c \ub429\ub2c8\ub2e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\uace0\uc131\ub2a5 \uac1c \ub179\ub0b4\uc7a5 \uce58\ub8cc \uc2dc\uc2a4\ud15c\uc5d0\uc11c \ucd5c\uc801\ud654\ub41c \uc5d0\ub108\uc9c0 \ube54\uc744 \uc870\uc0ac\ud568\uc73c\ub85c\uc368, \uc774\ub7ec\ud55c \uc0b0\ud654\uc9c8\uc18c \ucc28\ub2e8 \ud604\uc0c1\uc774 \ud574\uc18c\ub429\ub2c8\ub2e4. \uc774\ub97c \ud1b5\ud574 \uc0b0\uc18c\uac00 \ud6a8\uc18c \ubcf5\ud569\uccb4\uc5d0 \ud6a8\uc728\uc801\uc73c\ub85c \uacb0\ud569\ud558\uac8c \ub418\uc5b4, \ubbf8\ud1a0\ucf58\ub4dc\ub9ac\uc544 \ub9e4\ud2b8\ub9ad\uc2a4\ub97c \ud1b5\ud55c \uc815\uc0c1\uc801\uc778 \uc804\uc790 \ud750\ub984\uc774 \ud68c\ubcf5\ub429\ub2c8\ub2e4. \uadf8 \uacb0\uacfc \uc138\ud3ec\ub294 \ub354 \ub9ce\uc740 \uc544\ub370\ub178\uc2e0 \uc0bc\uc778\uc0b0(ATP)\uc744 \uc0dd\uc131\ud560 \uc218 \uc788\uac8c \ub418\uc5b4, \ud65c\uc131 \uc774\uc628 \ud38c\ud504\ub97c \uc791\ub3d9\uc2dc\ud0a4\uace0, \uc138\ud3ec \ub0b4 \ubd80\uc885\uc744 \uc644\ud654\ud558\uba70, \uc12c\ubaa8\uccb4 \uc138\ud3ec\uc758 \uc7ac\uad6c\uc131\uc744 \uac00\uc18d\ud654\ud558\ub294 \ub370 \ud544\uc694\ud55c \uc5d0\ub108\uc9c0\ub97c \uacf5\uae09\ud569\ub2c8\ub2e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ub3d9\uc2dc\uc5d0, 1470nm \ud30c\uc7a5\uc740 \uc8fc\ubcc0\uc758 \ub450\uaebc\uc6b4 \uadfc\ub9c9 \ub0b4 \uc218\ubd84 \ubd84\uc790\uc640 \uc9c1\uc811 \uc0c1\ud638\uc791\uc6a9\ud569\ub2c8\ub2e4. \uc774\ub7ec\ud55c \uc0c1\ud638\uc791\uc6a9\uc740 \ucd95\uc801\ub41c \uc138\ud3ec\uc678\uc561\uc758 \uc810\ub3c4\ub97c \ubcc0\ud654\uc2dc\ucf1c, \uc804\ubc29\uac01\uc5d0 \uac07\ud78c \uc5fc\uc99d \uc720\ubc1c \uc0ac\uc774\ud1a0\uce74\uc778\uc744 \uc81c\uac70\ud558\ub294 \ub370 \ub3c4\uc6c0\uc744 \uc90d\ub2c8\ub2e4. \ud5a5\uc0c1\ub41c \uc138\ud3ec \uc5d0\ub108\uc9c0\uc640 \uc2e0\uc18d\ud55c \uccb4\uc561 \ubc30\ucd9c\uc774 \uacb0\ud569\ub418\uba74 \uc548\uad6c \uc870\uc9c1\uc5d0 \uac00\ud574\uc9c0\ub294 \uc9c1\uc811\uc801\uc778 \ubb3c\ub9ac\uc801 \uc555\ub825\uc774 \ube60\ub974\uac8c \uac10\uc18c\ud558\uc5ec, \uae30\uc874\uc758 \ud45c\uba74 \uce58\ub8cc\ubc95\uc73c\ub85c\ub294 \ub2ec\uc131\ud560 \uc218 \uc5c6\ub294 \uc9c0\uc18d\uc801\uc778 \ud1b5\uc99d \uc644\ud654 \ubc0f \uad6c\uc870\uc801 \ud68c\ubcf5\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Procurement and Operational Infrastructure FAQ for Veterinary Networks<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\ub3c5\ub9bd\ud615 \uba40\ud2f0 \uc5b4\ub808\uc774 \ub4dc\ub77c\uc774\ubc84\uac00 \uc218\uc758\ud559\uc6a9 \uc548\uacfc \ub808\uc774\uc800\uc758 \uc7a5\uae30\uc801\uc778 \uc720\uc9c0\ubcf4\uc218 \ube44\uc6a9\uc744 \uc808\uac10\ud558\ub294 \uc774\uc720\ub294 \ubb34\uc5c7\uc77c\uae4c\uc694?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\uc77c\ubc18\uc801\uc778 \uc800\uac00\ud615 \ub808\uc774\uc800 \uae30\uae30\ub294 \ub0b4\ubd80 \ub808\uc774\uc800 \ubc29\ucd9c \uc18c\uc790\ub97c \ubaa8\ub450 \ud558\ub098\uc758 \uacf5\uc6a9 \ud68c\ub85c \uae30\ud310\uc5d0 \ubc30\uce58\ud558\ub294 \uacbd\uc6b0\uac00 \ub9ce\uc2b5\ub2c8\ub2e4. \uc774 \uacbd\uc6b0, \ub2e8 \ud558\ub098\uc758 \ubd80\ud488\uc774\ub098 \ud30c\uc7a5 \ucc44\ub110\uc5d0 \ubb38\uc81c\uac00 \ubc1c\uc0dd\ud574\ub3c4 \uae30\ud310 \uc804\uccb4\uac00 \uace0\uc7a5 \ub0a0 \uc218 \uc788\uc5b4, \ud074\ub9ac\ub2c9\uc5d0\uc11c\ub294 \uc2dc\uc220\uc744 \uc911\ub2e8\ud558\uace0 \uae30\uae30\ub97c \uacf5\uc7a5\uc73c\ub85c \ubcf4\ub0b4 \uace0\uac00\uc758 \uc218\ub9ac \ube44\uc6a9\uc744 \uc9c0\ubd88\ud574\uc57c\ub9cc \ud569\ub2c8\ub2e4. \ubaa8\ub4c8\uc2dd \uc124\uacc4\ub294 \uac01 \ud30c\uc7a5 \uc5b4\ub808\uc774\ub97c \ub3c5\ub9bd\uc801\uc778 \uc804\uc790 \ub4dc\ub77c\uc774\ubc84\ub85c \ubd84\ub9ac\ud569\ub2c8\ub2e4. \ud55c \ucc44\ub110\uc5d0 \ubb38\uc81c\uac00 \ubc1c\uc0dd\ud558\ub354\ub77c\ub3c4 \ub098\uba38\uc9c0 \uc5b4\ub808\uc774\uac00 \uc790\ub3d9\uc73c\ub85c \uc870\uc815\ub418\uc5b4 \uae30\uae30\uac00 \uc548\uc804\ud558\uac8c \uc791\ub3d9\ud558\ub3c4\ub85d \uc720\uc9c0\ud558\ubbc0\ub85c, \uc9c4\ub8cc\uc18c\uc758 \uc77c\uc0c1\uc801\uc778 \uc5c5\ubb34 \ud750\ub984\uc774 \ucd5c\uc18c\ud55c\uc758 \ucc28\uc9c8\ub9cc \uacaa\uc73c\uba70 \uacc4\uc18d\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ub9e5\ud30c \ub4c0\ud2f0 \uc0ac\uc774\ud074\uc744 \ub0ae\uac8c \uc124\uc815\ud558\uba74 \uacf5\ub9c9\uc744 \ud1b5\ud55c \uc2dc\uc220 \uc2dc \ubbfc\uac10\ud55c \uc548\uad6c \uc870\uc9c1\uc744 \uc5b4\ub5bb\uac8c \ubcf4\ud638\ud560 \uc218 \uc788\ub098\uc694?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\ub808\uc774\uc800\uac00 \uc5d0\ub108\uc9c0\ub97c \uc9c0\uc18d\uc801\uc73c\ub85c \ubc29\ucd9c\ud560 \uacbd\uc6b0, \uc808\uac1c \uac00\uc7a5\uc790\ub9ac\ub97c \ub530\ub77c \uc870\uc9c1 \ub0b4\uc5d0 \uc5f4\uc774 \ube60\ub974\uac8c \ucd95\uc801\ub418\uc5b4 \uad6c\uc870\uc801 \ud749\ud130 \ud615\uc131 \ubc0f \uc870\uc9c1 \uc720\ucc29\uc758 \uc704\ud5d8\uc774 \ubc1c\uc0dd\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ub0ae\uc740 \ud384\uc2a4 \ub4c0\ud2f0 \uc0ac\uc774\ud074(\uc608: 15% ~ 25%)\uc740 \ub808\uc774\uc800 \uc5d0\ub108\uc9c0\ub97c \ub9c8\uc774\ud06c\ub85c\ucd08 \ub2e8\uc704\uc758 \ube60\ub978 \ud384\uc2a4\ub85c \ubc29\ucd9c\ud558\uc5ec, \uac01 \ud384\uc2a4 \uc0ac\uc774\uc5d0 \uc9e7\uc740 \uc5f4 \uc774\uc644 \uc2dc\uac04\uc744 \ud655\ubcf4\ud569\ub2c8\ub2e4. \uc774\ub7ec\ud55c \uac04\uaca9\uc744 \ud1b5\ud574 \uad6d\uc18c \uccb4\uc561\uc774 \uc9c0\uc18d\uc801\uc73c\ub85c \ud750\ub974\uba70 \uacfc\ub3c4\ud55c \ud45c\uba74 \uc5f4\uc744 \uc81c\uac70\ud568\uc73c\ub85c\uc368, \uc12c\uc138\ud55c \uacf5\ub9c9 \ubc0f \uac01\ub9c9 \uad6c\uc870\uac00 \uc7a5\uae30\uc801\uc778 \ud749\ud130 \ud615\uc131\uc774\ub098 \uc5f4\uc801 \uc190\uc0c1\uc73c\ub85c\ubd80\ud130 \ubcf4\ud638\ub429\ub2c8\ub2e4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\uac15\ucca0 \ubcf4\uac15 \ucffc\uce20 \uc804\uc1a1 \uad11\uc12c\uc720\ub294 \uc77c\ubc18 \ud50c\ub77c\uc2a4\ud2f1 \uad11\uc12c\uc720\uc5d0 \ube44\ud574 \uad6c\uc870\uc801\uc73c\ub85c \uc5b4\ub5a4 \uc7a5\uc810\uc774 \uc788\uc2b5\ub2c8\uae4c?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\uc77c\ubc18\uc801\uc778 \ud50c\ub77c\uc2a4\ud2f1\uc774\ub098 \uc720\ub9ac\uc12c\uc720 \uc18c\uc7ac\uc758 \ud638\uc2a4\ub294 \ub9e4\uc6b0 \ucde8\uc57d\ud558\uc5ec, \uc77c\uc0c1\uc801\uc778 \uc218\uae30 \uce58\ub8cc \uc900\ube44 \uacfc\uc815\uc5d0\uc11c \uad6c\ubd80\ub7ec\uc9c0\uac70\ub098 \uc6c0\uc9c1\uc77c \ub54c \ub0b4\ubd80\uc5d0 \ubbf8\uc138 \uade0\uc5f4\uc774 \uc0dd\uae30\uae30 \uc27d\uc2b5\ub2c8\ub2e4. \uc774\ub7ec\ud55c \ubbf8\uc138 \uade0\uc5f4\ub85c \uc778\ud574 \ube5b\uc774 \ub0b4\ubd80\ub85c \uc0c8\uc5b4 \ub098\uac00 \uc2e4\uc81c \uce58\ub8cc\ub7c9\uc774 \uac10\uc18c\ud560 \ubfd0\ub9cc \uc544\ub2c8\ub77c, \ud578\ub4dc\ud53c\uc2a4 \ud638\uc2a4\ub97c \uc190\uc0c1\uc2dc\ud0ac \uc218 \uc788\ub294 \ub0b4\ubd80 \uacfc\uc5f4 \ubd80\uc704\uac00 \ubc1c\uc0dd\ud569\ub2c8\ub2e4. \uac15\ucca0\uc73c\ub85c \ubcf4\uac15\ub41c \uc11d\uc601 \uc12c\uc720\ub294 \uad6c\ubd80\ub7ec\uc9d0\uacfc \ube44\ud2c0\ub9bc\uc5d0 \ub300\ud55c \ub6f0\uc5b4\ub09c \ub0b4\uad6c\uc131\uc744 \uc81c\uacf5\ud558\uc5ec, \uadc0\uc911\ud55c \uc7a5\ube44 \ud22c\uc790\ub97c \ubcf4\ud638\ud558\uace0 \ub9e4\uc77c\uc758 \ud658\uc790 \uce58\ub8cc\uac00 \uc6d0\ud65c\ud558\uac8c \uc9c4\ud589\ub420 \uc218 \uc788\ub3c4\ub85d \ud569\ub2c8\ub2e4.<\/p>","protected":false},"excerpt":{"rendered":"<p>Veterinary ophthalmologists face an acute clinical challenge when managing primary or secondary canine glaucoma: delivering enough optical energy to transsclerally ablate portions of the ciliary body epithelium without burning the highly sensitive, overlying scleral matrices. Standard continuous-wave lasers cook superficial ocular layers, causing immediate tissue contraction, scleral thinning, and post-operative spikes in painful inflammation that [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[19],"tags":[840],"class_list":["post-15895","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-veterinary-laser-therapy"],"metadata":{"_edit_lock":["1782110302:1"],"_edit_last":["1"],"_aioseo_title":["Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance"],"_aioseo_description":["A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"catce":["sidebar-widgets4"],"wpil_sync_report3":["1"],"views":["19"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"ko_KR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance\" \/>\n\t\t<meta property=\"og:description\" content=\"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-06-24T08:00:21+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-06-24T08:00:21+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance\" \/>\n\t\t<meta name=\"twitter:description\" content=\"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#blogposting\",\"name\":\"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance\",\"headline\":\"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/author\\\/fengmaiadmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/dog-laser-therapy120.jpg\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#articleImage\",\"width\":400,\"height\":374,\"caption\":\"Veterinary professional applying laser therapy to a white dog in a clinical exam room with monitors in the background\"},\"datePublished\":\"2026-06-24T16:00:21+08:00\",\"dateModified\":\"2026-06-24T16:00:21+08:00\",\"inLanguage\":\"ko-KR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#webpage\"},\"articleSection\":\"Industry News, Veterinary Laser Therapy\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/ko\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/industry-news\\\/#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/industry-news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#listItem\",\"name\":\"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#listItem\",\"position\":4,\"name\":\"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/category\\\/news\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/author\\\/fengmaiadmin\\\/#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/author\\\/fengmaiadmin\\\/\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/\",\"name\":\"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance\",\"description\":\"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.\",\"inLanguage\":\"ko-KR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/author\\\/fengmaiadmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/author\\\/fengmaiadmin\\\/#author\"},\"datePublished\":\"2026-06-24T16:00:21+08:00\",\"dateModified\":\"2026-06-24T16:00:21+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"ko-KR\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/ko\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance<\/title>\n\n","aioseo_head_json":{"title":"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance","description":"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.","canonical_url":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#blogposting","name":"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance","headline":"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring","author":{"@id":"https:\/\/fotonmedix.com\/ko\/author\/fengmaiadmin\/#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/ko\/#person"},"image":{"@type":"ImageObject","url":"https:\/\/fotonmedix.com\/wp-content\/uploads\/2026\/06\/dog-laser-therapy120.jpg","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#articleImage","width":400,"height":374,"caption":"Veterinary professional applying laser therapy to a white dog in a clinical exam room with monitors in the background"},"datePublished":"2026-06-24T16:00:21+08:00","dateModified":"2026-06-24T16:00:21+08:00","inLanguage":"ko-KR","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#webpage"},"articleSection":"Industry News, Veterinary Laser Therapy"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/ko","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/category\/news\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/category\/news\/#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/ko\/category\/news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/category\/news\/industry-news\/#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/category\/news\/industry-news\/#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/ko\/category\/news\/industry-news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#listItem","name":"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/category\/news\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#listItem","position":4,"name":"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/ko\/category\/news\/industry-news\/#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/ko\/author\/fengmaiadmin\/#author","url":"https:\/\/fotonmedix.com\/ko\/author\/fengmaiadmin\/","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#webpage","url":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/","name":"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance","description":"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.","inLanguage":"ko-KR","isPartOf":{"@id":"https:\/\/fotonmedix.com\/ko\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/ko\/author\/fengmaiadmin\/#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/ko\/author\/fengmaiadmin\/#author"},"datePublished":"2026-06-24T16:00:21+08:00","dateModified":"2026-06-24T16:00:21+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/ko\/#website","url":"https:\/\/fotonmedix.com\/ko\/","name":"FotonMedix","inLanguage":"ko-KR","publisher":{"@id":"https:\/\/fotonmedix.com\/ko\/#person"}}]},"og:locale":"ko_KR","og:site_name":"FotonMedix |","og:type":"article","og:title":"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance","og:description":"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.","og:url":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/","article:published_time":"2026-06-24T08:00:21+00:00","article:modified_time":"2026-06-24T08:00:21+00:00","twitter:card":"summary_large_image","twitter:title":"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance","twitter:description":"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars."},"aioseo_meta_data":{"post_id":"15895","title":"Glaucoma Laser Surgery Restores Canine Aqueous Fluid Balance","description":"A clinical study on using dual-wavelength veterinary laser therapy equipment to treat acute canine intraocular pressure spikes without surface thermal scars.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-06-24 08:19:11","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-06-22 06:37:27","updated":"2026-06-24 08:19:11"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/ko\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/ko\/category\/news\/\" title=\"News\">News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/fotonmedix.com\/ko\/category\/news\/industry-news\/\" title=\"Industry News\">Industry News<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tMicrosecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/ko"},{"label":"News","link":"https:\/\/fotonmedix.com\/ko\/category\/news\/"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/ko\/category\/news\/industry-news\/"},{"label":"Microsecond Pulse Gating Resolves High Intraocular Pressure Spikes Without Scleral Scarring","link":"https:\/\/fotonmedix.com\/ko\/microsecond-pulse-gating-resolves-high-intraocular-pressure-spikes-without-scleral-scarring.html\/"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/posts\/15895","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/comments?post=15895"}],"version-history":[{"count":2,"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/posts\/15895\/revisions"}],"predecessor-version":[{"id":16148,"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/posts\/15895\/revisions\/16148"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/media?parent=15895"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/categories?post=15895"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/ko\/wp-json\/wp\/v2\/tags?post=15895"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}