{"id":12490,"date":"2026-04-04T12:08:00","date_gmt":"2026-04-04T04:08:00","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-04-23T10:44:18","modified_gmt":"2026-04-23T02:44:18","slug":"micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/","title":{"rendered":"Tecnologia de Diodo Micro-Pulso: Uma Fronteira N\u00e3o Destrutiva no Tratamento do Glaucoma Cr\u00f3nico Canino"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A mudan\u00e7a cl\u00ednica em <strong>tratamento do glaucoma em c\u00e3es<\/strong> enfatiza a transi\u00e7\u00e3o da destrui\u00e7\u00e3o t\u00e9rmica por ondas cont\u00ednuas para a ciclofotocoagula\u00e7\u00e3o transescleral por micro-pulsos (MP-TSCPC), utilizando rajadas de alta frequ\u00eancia de 810nm\/980nm para modular o fluxo de humor aquoso, preservando a integridade estrutural do corpo ciliar e a barreira hemato-acosa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A f\u00edsica do relaxamento t\u00e9rmico e da portabilidade de micro-pulsos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">No campo especializado da oftalmologia veterin\u00e1ria, o \u201cGold Standard\u201d para gerir a press\u00e3o intraocular (PIO) evoluiu atrav\u00e9s da compreens\u00e3o do tempo de relaxamento t\u00e9rmico (TRT). Quando um <strong>m\u00e1quina de cirurgia laser veterin\u00e1ria<\/strong> fornece energia numa onda cont\u00ednua (CW), o calor espalha-se rapidamente do epit\u00e9lio ciliar pigmentado para o epit\u00e9lio n\u00e3o pigmentado e para a \u00favea circundante, resultando frequentemente em \u201cPhthisis Bulbi\u201d - o encolhimento permanente do globo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para atenuar esta situa\u00e7\u00e3o, os <strong>cirurgia a laser para o glaucoma<\/strong> utiliza a tecnologia de micro-pulsos. Ao fragmentar uma \u00fanica emiss\u00e3o de laser numa s\u00e9rie de ciclos de micro-segundos \u201cOn\u201d e \u201cOff\u201d, permitimos que o tecido arrefe\u00e7a entre os impulsos. O ciclo de trabalho ($DC$) \u00e9 o par\u00e2metro cr\u00edtico neste caso:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">$$DC = \\frac{t_{on}}{t_{on} + t_{off}} \\times 100\\%$$<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Onde:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>$t_{on}$ \u00e9 a dura\u00e7\u00e3o do impulso laser (normalmente 0,5ms).<\/li>\n\n\n\n<li>$t_{off}$ \u00e9 o per\u00edodo de repouso.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para um gestor de aquisi\u00e7\u00f5es B2B, a capacidade do VetMedix 3000U5 de manter um ciclo de funcionamento de 31,3% garante que o corpo ciliar atinge o \u2019limiar de fotocoagula\u00e7\u00e3o\u201c sem ultrapassar o \u201dlimiar de carboniza\u00e7\u00e3o\u201c. Esta abordagem sub-limiar desencadeia uma reestrutura\u00e7\u00e3o biol\u00f3gica da malha trabecular e das vias de escoamento uveosclerais, reduzindo efetivamente a PIO sem a inflama\u00e7\u00e3o necr\u00f3tica t\u00edpica dos sistemas mais antigos. <strong>cirurgia a laser para glaucoma<\/strong> protocolos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Efic\u00e1cia cl\u00ednica: Controlo do Glaucoma Secund\u00e1rio e da Hipertens\u00e3o Induzida por Uve\u00edte<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Enquanto o glaucoma prim\u00e1rio \u00e9 uma patologia comum espec\u00edfica da ra\u00e7a, o glaucoma secund\u00e1rio - frequentemente resultante de uve\u00edte cr\u00f3nica ou luxa\u00e7\u00e3o do cristalino - representa um desafio inflamat\u00f3rio mais complexo. Tradicional <strong>tratamento do glaucoma em c\u00e3es<\/strong> A utiliza\u00e7\u00e3o de gotas hipotensoras (por exemplo, Timolol) \u00e9 frequentemente insuficiente porque os detritos inflamat\u00f3rios subjacentes obstruem fisicamente o \u00e2ngulo de drenagem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A integra\u00e7\u00e3o dos comprimentos de onda de 980 nm e 1470 nm na s\u00e9rie SurgMedix permite ao cirurgi\u00e3o abordar tanto a PIO como a inflama\u00e7\u00e3o localizada. O comprimento de onda de 980 nm proporciona uma excelente absor\u00e7\u00e3o de hemoglobina para selar vasos uveais menores, enquanto a energia do \u201cpico de \u00e1gua\u201d de 1470 nm pode ser utilizada para efetuar uma iridectomia perif\u00e9rica precisa para aliviar o bloqueio pupilar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Tabela comparativa: Resultados cir\u00fargicos e taxas de complica\u00e7\u00f5es<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>M\u00e9trica de desempenho<\/strong><\/td><td><strong>Transescleral CW (onda cont\u00ednua)<\/strong><\/td><td><strong>ECP endosc\u00f3pico (Fotonmedix)<\/strong><\/td><td><strong>Micro-Pulso TSCPC<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Redu\u00e7\u00e3o da PIO (%)<\/strong><\/td><td>40 - 60%<\/td><td>35 - 50%<\/td><td>30 - 45%<\/td><\/tr><tr><td><strong>Risco de Phthisis Bulbi<\/strong><\/td><td>Elevado (15-20%)<\/td><td>Baixo (&lt; 5%)<\/td><td>M\u00ednimo (&lt; 1%)<\/td><\/tr><tr><td><strong>Uve\u00edte p\u00f3s-operat\u00f3ria<\/strong><\/td><td>Grave<\/td><td>Suave<\/td><td>Negligenci\u00e1vel<\/td><\/tr><tr><td><strong>Repetibilidade<\/strong><\/td><td>Baixo (Cicatriza\u00e7\u00e3o dos tecidos)<\/td><td>Moderado<\/td><td>Elevado (N\u00e3o destrutivo)<\/td><\/tr><tr><td><strong>Manuten\u00e7\u00e3o da vis\u00e3o<\/strong><\/td><td>Vari\u00e1vel<\/td><td>Superior<\/td><td>Excelente<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Para os distribuidores regionais, a narrativa \u201cMicro-Pulse\u201d \u00e9 um diferenciador B2B fundamental. Passa de \u201ccirurgia de \u00faltimo recurso\u201d para \u201cinterven\u00e7\u00e3o em fase inicial\u201d, expandindo significativamente o mercado endere\u00e7\u00e1vel para <strong>cirurgia a laser para o glaucoma<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Estudo de caso cl\u00ednico: Glaucoma Prim\u00e1rio em Est\u00e1gio Inicial em um Husky Siberiano de 6 Anos de Idade<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Antecedentes e diagn\u00f3stico do doente<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Assunto:<\/strong> F\u00eamea de 6 anos de idade da ra\u00e7a Husky Siberiano.<\/li>\n\n\n\n<li><strong>Diagn\u00f3stico:<\/strong> Glaucoma prim\u00e1rio de encerramento angular (PACG) em fase inicial. A gonioscopia revelou $360^\\circ$ de displasia do ligamento pectinado.<\/li>\n\n\n\n<li><strong>Apresenta\u00e7\u00e3o cl\u00ednica:<\/strong> PIO de 32 mmHg no olho esquerdo (SO). A do olho direito (OD) era de 20 mmHg, mas considerada de alto risco.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Estrat\u00e9gia de interven\u00e7\u00e3o e par\u00e2metros t\u00e9cnicos<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">O objetivo era utilizar o sistema VetMedix para um tratamento n\u00e3o invasivo e que n\u00e3o prejudicasse a vis\u00e3o, a fim de retardar o aparecimento de uma crise glaucomatosa.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Par\u00e2metro<\/strong><\/td><td><strong>Configura\u00e7\u00e3o t\u00e9cnica<\/strong><\/td><td><strong>L\u00f3gica cl\u00ednica<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Comprimento de onda<\/strong><\/td><td>810 nm<\/td><td>Pico de absor\u00e7\u00e3o de melanina no corpo ciliar<\/td><\/tr><tr><td><strong>Modo de entrega<\/strong><\/td><td>Micro-Pulse (MP3)<\/td><td>Preserva\u00e7\u00e3o do tecido uveal<\/td><\/tr><tr><td><strong>Intensidade de pot\u00eancia<\/strong><\/td><td>2000 mW<\/td><td>Suficiente para a penetra\u00e7\u00e3o transescleral<\/td><\/tr><tr><td><strong>Ciclo de trabalho<\/strong><\/td><td>31.3%<\/td><td>Relaxamento t\u00e9rmico controlado<\/td><\/tr><tr><td><strong>Tempo de tratamento<\/strong><\/td><td>90 segundos por hemisf\u00e9rio<\/td><td>Varrimento abrangente de 360 graus<\/td><\/tr><tr><td><strong>T\u00e9cnica de sonda<\/strong><\/td><td>Transescleral (sonda de glaucoma)<\/td><td>N\u00e3o \u00e9 necess\u00e1ria entrada intraocular<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Progress\u00e3o p\u00f3s-operat\u00f3ria<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Dia 7:<\/strong> A PIO baixou para 18 mmHg OS sem qualquer altera\u00e7\u00e3o da medica\u00e7\u00e3o. Sem sinais vis\u00edveis de inflama\u00e7\u00e3o ocular.<\/li>\n\n\n\n<li><strong>M\u00eas 3:<\/strong> A PIO mant\u00e9m-se est\u00e1vel entre 16-19 mmHg. O doente necessitou apenas de uma \u00fanica gota profil\u00e1ctica duas vezes por dia.<\/li>\n\n\n\n<li><strong>Conclus\u00e3o final:<\/strong> Ao utilizar <strong><a href=\"https:\/\/fotonmedix.com\/pt\/advanced-diode-laser-endocyclophotocoagulation-a-paradigm-shift-in-canine-glaucoma-management.html\/\" title=\"Endociclofotocoagula\u00e7\u00e3o avan\u00e7ada com laser de d\u00edodo: Uma Mudan\u00e7a de Paradigma no Tratamento do Glaucoma Canino\"  data-wpil-monitor-id=\"4094\">laser para glaucoma canino<\/a> tratamento<\/strong> numa fase inicial, evit\u00e1mos os \u201cpicos\u201d agudos de press\u00e3o que causam a morte das c\u00e9lulas ganglionares da retina. Este caso real\u00e7a a forma como a tecnologia laser de classe 4 actua como uma modalidade \u201cneuroprotectora\u201d ao manter a press\u00e3o intraocular homeost\u00e1tica.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Mitiga\u00e7\u00e3o de riscos B2B: Protocolos de manuten\u00e7\u00e3o e seguran\u00e7a de dispositivos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para os administradores hospitalares, a fiabilidade de um <strong>cirurgia a laser para glaucoma<\/strong> O sucesso da unidade de refrigera\u00e7\u00e3o \u00e9 t\u00e3o importante como o seu sucesso cl\u00ednico. Nos sistemas de d\u00edodos de alta pot\u00eancia, a arquitetura de arrefecimento \u00e9 o principal ponto de falha.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Gest\u00e3o t\u00e9rmica e integridade do d\u00edodo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Os sistemas Fotonmedix utilizam um sistema de arrefecimento termoel\u00e9trico ativo (TEC). Durante uma varredura de micro-pulsos de 90 segundos, o m\u00f3dulo de d\u00edodos gera um calor intenso. Se o arrefecimento falhar, o comprimento de onda pode deslocar-se at\u00e9 5nm por $10^\\circ C$, afastando potencialmente a energia do pico de absor\u00e7\u00e3o da melanina. Os nossos contratos de servi\u00e7o B2B incluem a calibra\u00e7\u00e3o semestral do TEC para garantir a estabilidade do comprimento de onda e a longevidade do d\u00edodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Seguran\u00e7a e conformidade ocular<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Prote\u00e7\u00e3o das fibras:<\/strong> As fibras oft\u00e1lmicas s\u00e3o propensas \u00e0 \u201cperda de revestimento\u201d se forem dobradas para al\u00e9m do seu raio de curvatura m\u00ednimo ($&lt; 30mm$). Fornecemos fibras refor\u00e7adas e blindadas para evitar rupturas acidentais em salas de espet\u00e1culo movimentadas.<\/li>\n\n\n\n<li><strong>Prote\u00e7\u00e3o do pessoal:<\/strong> Uma vez que 810nm e 980nm s\u00e3o invis\u00edveis ao olho humano, o indicador de \u201cEmiss\u00e3o Ativa\u201d tem de ser visual e auditivo. Todas as unidades Fotonmedix incluem um anel LED de alta visibilidade na pe\u00e7a de m\u00e3o para sinalizar a emiss\u00e3o ativa \u00e0 equipa cir\u00fargica.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">O futuro da oftalmologia veterin\u00e1ria: Dosimetria automatizada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ao olharmos para o roteiro de produtos de 2027, a integra\u00e7\u00e3o de sensores IOP em tempo real com o <strong>veterin\u00e1ria <a href=\"https:\/\/fotonmedix.com\/pt\/integrated-photothermal-solutions-synergistic-management-of-perianal-fistulas-and-chronic-dermatological-pathologies-in-canine-patients.html\/\" title=\"Solu\u00e7\u00f5es fotot\u00e9rmicas integradas: Gest\u00e3o sin\u00e9rgica de f\u00edstulas perianais e patologias dermatol\u00f3gicas cr\u00f3nicas em pacientes caninos\"  data-wpil-monitor-id=\"4005\">m\u00e1quina de terapia laser<\/a><\/strong> permitir\u00e1 a \u201cDosimetria Inteligente\u201d. A m\u00e1quina interromper\u00e1 automaticamente a emiss\u00e3o assim que a imped\u00e2ncia do corpo ciliar alvo for atingida, reduzindo ainda mais o risco de tratamento excessivo. Para os parceiros B2B, isto representa o pr\u00f3ximo salto em \u201ccuidados estandardizados\u201d, permitindo que at\u00e9 os m\u00e9dicos de cl\u00ednica geral efectuem <strong>tratamento do glaucoma em c\u00e3es<\/strong> com a precis\u00e3o de um especialista.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">FAQ: Suporte t\u00e9cnico profissional para cl\u00ednicas<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. A tecnologia Micro-Pulse pode ser utilizada em olhos \u201cem fase terminal\u201d (cegos)?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Embora possa ser utilizada para o controlo da dor, a abla\u00e7\u00e3o de onda cont\u00ednua (CW) \u00e9 frequentemente preferida para os olhos em fase terminal para garantir uma queda permanente da press\u00e3o, uma vez que a preserva\u00e7\u00e3o da vis\u00e3o j\u00e1 n\u00e3o \u00e9 um objetivo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Como \u00e9 que o comprimento de onda de 1470 nm ajuda na cirurgia do glaucoma?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Embora n\u00e3o seja o comprimento de onda principal para a ciclofotocoagula\u00e7\u00e3o, o 1470 nm \u00e9 excelente para o tratamento do glaucoma secund\u00e1rio causado por tumores ou quistos da c\u00e2mara anterior, uma vez que pode vaporizar estes tecidos ricos em \u00e1gua com um m\u00ednimo de hemorragia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Qual \u00e9 a \u201ccurva de aprendizagem\u201d da cirurgia laser transescleral?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A t\u00e9cnica \u201cSweep\u201d para a TSCPC de micro-pulsos \u00e9 relativamente intuitiva. A maioria dos cirurgi\u00f5es adquire profici\u00eancia ap\u00f3s 5-10 casos, desde que sigam as tabelas de dosimetria fornecidas no manual cl\u00ednico da Fotonmedix.<\/p>","protected":false},"excerpt":{"rendered":"<p>The clinical shift in glaucoma in dogs treatment emphasizes the transition from continuous-wave thermal destruction to micro-pulse transscleral cyclophotocoagulation (MP-TSCPC), utilizing high-frequency 810nm\/980nm bursts to modulate aqueous humor outflow while preserving the structural integrity of the ciliary body and the blood-aqueous barrier. The Physics of Thermal Relaxation and Micro-Pulse Gating In the specialized field of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"slim_seo":{"title":"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management - FotonMedix","description":"The clinical shift in glaucoma in dogs treatment emphasizes the transition from continuous-wave thermal destruction to micro-pulse transscleral cyclophotocoagul"},"footnotes":""},"categories":[19],"tags":[815,839,840],"class_list":["post-12490","post","type-post","status-publish","format-standard","hentry","category-industry-news","tag-laser-therapy-machine","tag-laser-surgery","tag-veterinary-laser-therapy"],"metadata":{"_facebook_share_type":["default"],"_twitter_share_type":["default"],"_linkedin_share_type":["default"],"_pinterest_share_type":["default"],"_instagram_share_type":["default"],"_medium_share_type":["default"],"_threads_share_type":["default"],"_google_business_share_type":["default"],"_wpsp_custom_templates":["a:7:{s:8:\"facebook\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:7:\"twitter\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:8:\"linkedin\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:9:\"pinterest\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:9:\"instagram\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:6:\"medium\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}s:7:\"threads\";a:3:{s:8:\"template\";s:0:\"\";s:8:\"profiles\";a:0:{}s:9:\"is_global\";b:0;}}"],"_edit_lock":["1774859703:1"],"_wpsp_social_scheduling":["a:11:{s:7:\"enabled\";b:0;s:8:\"datetime\";N;s:9:\"platforms\";a:0:{}s:6:\"status\";s:13:\"template_only\";s:10:\"dateOption\";s:5:\"today\";s:10:\"timeOption\";s:3:\"now\";s:10:\"customDays\";s:0:\"\";s:11:\"customHours\";s:0:\"\";s:10:\"customDate\";s:0:\"\";s:10:\"customTime\";s:0:\"\";s:14:\"schedulingType\";s:8:\"absolute\";}"],"themepark_post_bcolor":["#f5f5f5"],"themepark_post_width":["1022px"],"themepark_post_img":[""],"themepark_post_img_po":["left"],"themepark_post_img_re":[""],"themepark_post_img_cover":[""],"themepark_post_img_fixed":[""],"themepark_post_hide_title":[""],"themepark_post_main_b":[""],"themepark_post_main_p":["100"],"themepark_paddingblock":[""],"footnotes":[""],"_wpscp_schedule_draft_date":[""],"_wpscp_schedule_republish_date":[""],"_wpscppro_advance_schedule_date":[""],"_wpscppro_dont_share_socialmedia":[""],"_wpscppro_custom_social_share_image":["0"],"_linkedin_share_type_page":["default"],"_selected_social_profile":["a:0:{}"],"_wpsp_enable_custom_social_template":[""],"_wpsp_active_default_template":["1"],"_edit_last":["1"],"_aioseo_title":["Canine Glaucoma Laser Surgery: Micro-Pulse Technology"],"_aioseo_description":["Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics."],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"catce":["sidebar-widgets4"],"views":["581"],"wpil_links_inbound_internal_count":["1"],"wpil_links_inbound_internal_count_data":["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"],"wpil_links_outbound_internal_count":["2"],"wpil_links_outbound_internal_count_data":["eJzlU8uO2zAM\/JVAd23sPLaJ8gt93Xo0uJJsEytLhkS3GwT591JWEiQoemgPiwK9SRQ5mhmSoFbqhKo6fFH1VolvI7rmUzDWNR\/RvwpVr9UpqQ9KOL42aMQhJye1VmKKTvCpXq2U6InGpJbLNlDwgzX49qTDsATzHby2RhpkTOkg2SitN0EftQtjz9k6QDc5IAxeghwhgsFukKnHliR6qcGjt7JzMDEiyAE8dHawnp56GtwyU9gwgZBoZsPnRxI5ulMCPdnogSm\/qLrUjHPNL8K\/5nAGYuEsrWiuV5vdmss4lZCcFYfPBYSOoxX3eEk9K5EIaEolic3TgX\/3VO7bYma6QSQ3deXCldqhvr7tZkzM3pRAZhpix5bohiK0LepbIeulEC95tRKg2+bh370SgyVoDBCIA6hKnc65fSwxNcmG5ibsPANy5\/oMyC4wXOnD4tqHxdxLceEExljTvBybkaWgzx5Xhb8LGgr\/RyMYtLoM1Y8e02hjo6MFssXtiwYmBhOFnHYdvBxm6foVfTfP42zhptpvxOV1CGZytnkoWl3+mv9\/oxI\/54\/+fu6fN7+d+zxsXcxq5Dzk1Ns4gJMpuCm7kWQ6ehs7TIT6bqRlaCVbgRxwsuVX3owkwRup+xi469JkIHYkdKg5ZwTq54tNd8vCUWS09L4bUu93u\/95Q+aNWORWw3hcDKB77sU\/tCHV9s835PwTTPoG7Q=="],"wpil_links_outbound_external_count":["0"],"wpil_links_outbound_external_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_sync_report3":["1"],"wpil_sync_report2_time":["2026-08-06T09:30:39+00:00"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.0.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.0.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"pt_PT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Canine Glaucoma Laser Surgery: Micro-Pulse Technology\" \/>\n\t\t<meta property=\"og:description\" content=\"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-04-04T04:08:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-04-23T02:44:18+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Canine Glaucoma Laser Surgery: Micro-Pulse Technology\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#blogposting\",\"name\":\"Canine Glaucoma Laser Surgery: Micro-Pulse Technology\",\"headline\":\"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#articleImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"},\"datePublished\":\"2026-04-04T12:08:00+08:00\",\"dateModified\":\"2026-04-23T10:44:18+08:00\",\"inLanguage\":\"pt-PT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#webpage\"},\"articleSection\":\"Industry News, Laser Therapy Machine, Laser Surgery, Veterinary Laser Therapy\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/pt\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news\\\/#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#listItem\",\"name\":\"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#listItem\",\"position\":4,\"name\":\"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news\\\/#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin\\\/#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin\\\/\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/\",\"name\":\"Canine Glaucoma Laser Surgery: Micro-Pulse Technology\",\"description\":\"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\\\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics.\",\"inLanguage\":\"pt-PT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin\\\/#author\"},\"datePublished\":\"2026-04-04T12:08:00+08:00\",\"dateModified\":\"2026-04-23T10:44:18+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"pt-PT\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Cirurgia a laser para glaucoma canino: Tecnologia de micro-pulsos","description":"Guia t\u00e9cnico sobre cirurgia laser de micro-pulsos para glaucoma em c\u00e3es. Explore protocolos de 810nm\/980nm, relaxamento t\u00e9rmico e aquisi\u00e7\u00e3o B2B para cl\u00ednicas veterin\u00e1rias.","canonical_url":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#blogposting","name":"Canine Glaucoma Laser Surgery: Micro-Pulse Technology","headline":"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management","author":{"@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin\/#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/pt\/#person"},"image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#articleImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"},"datePublished":"2026-04-04T12:08:00+08:00","dateModified":"2026-04-23T10:44:18+08:00","inLanguage":"pt-PT","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#webpage"},"articleSection":"Industry News, Laser Therapy Machine, Laser Surgery, Veterinary Laser Therapy"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/pt","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\/#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\/#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#listItem","name":"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#listItem","position":4,"name":"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\/#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin\/#author","url":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin\/","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#webpage","url":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/","name":"Canine Glaucoma Laser Surgery: Micro-Pulse Technology","description":"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics.","inLanguage":"pt-PT","isPartOf":{"@id":"https:\/\/fotonmedix.com\/pt\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin\/#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin\/#author"},"datePublished":"2026-04-04T12:08:00+08:00","dateModified":"2026-04-23T10:44:18+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/pt\/#website","url":"https:\/\/fotonmedix.com\/pt\/","name":"FotonMedix","inLanguage":"pt-PT","publisher":{"@id":"https:\/\/fotonmedix.com\/pt\/#person"}}]},"og:locale":"pt_PT","og:site_name":"FotonMedix |","og:type":"article","og:title":"Canine Glaucoma Laser Surgery: Micro-Pulse Technology","og:description":"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics.","og:url":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/","article:published_time":"2026-04-04T04:08:00+00:00","article:modified_time":"2026-04-23T02:44:18+00:00","twitter:card":"summary_large_image","twitter:title":"Canine Glaucoma Laser Surgery: Micro-Pulse Technology","twitter:description":"Technical guide on micro-pulse laser surgery for glaucoma in dogs. Explore 810nm\/980nm protocols, thermal relaxation, and B2B procurement for vet clinics."},"aioseo_meta_data":{"post_id":"12490","title":"Cirurgia a laser para glaucoma canino: Tecnologia de micro-pulsos","description":"Guia t\u00e9cnico sobre cirurgia laser de micro-pulsos para glaucoma em c\u00e3es. Explore protocolos de 810nm\/980nm, relaxamento t\u00e9rmico e aquisi\u00e7\u00e3o B2B para cl\u00ednicas veterin\u00e1rias.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-04-28 02:06:28","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-03-30 08:34:23","updated":"2026-04-28 02:06:28","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/pt\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/\" title=\"News\">News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\/\" title=\"Industry News\">Industry News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tMicro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/pt"},{"label":"News","link":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\/"},{"label":"Micro-Pulse Diode Technology: A Non-Destructive Frontier in Chronic Canine Glaucoma Management","link":"https:\/\/fotonmedix.com\/pt\/micro-pulse-diode-technology-a-non-destructive-frontier-in-chronic-canine-glaucoma-management.html\/"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts\/12490","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/comments?post=12490"}],"version-history":[{"count":3,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts\/12490\/revisions"}],"predecessor-version":[{"id":13520,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts\/12490\/revisions\/13520"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/media?parent=12490"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/categories?post=12490"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/tags?post=12490"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}