{"id":14845,"date":"2026-07-04T19:30:38","date_gmt":"2026-07-04T11:30:38","guid":{"rendered":"https:\/\/fotonmedix.com\/"},"modified":"2026-07-04T19:30:38","modified_gmt":"2026-07-04T11:30:38","slug":"managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation","status":"publish","type":"post","link":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html","title":{"rendered":"Tratamento da tortuosidade da veia safena na EVLT sem perfura\u00e7\u00e3o do vaso"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A navega\u00e7\u00e3o por segmentos tortuosos da veia safena maior durante procedimentos a laser EVLT requer um sistema de administra\u00e7\u00e3o de fibra \u00f3tica m\u00e9dica flex\u00edvel de 400 \u00b5m, combinado com um comprimento de onda de 980 nm, para conseguir uma abla\u00e7\u00e3o transmural uniforme, evitando simultaneamente a rutura localizada da parede venosa.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Obst\u00e1culos mec\u00e2nicos na navega\u00e7\u00e3o por segmentos venosos tortuosos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Os especialistas em medicina vascular deparam-se frequentemente com varia\u00e7\u00f5es anat\u00f3micas extremas ao tratar o refluxo venoso superficial avan\u00e7ado. Os canais altamente tortuosos no interior das veias safenas acess\u00f3rias ou no ter\u00e7o inferior da veia safena maior (VSG) representam s\u00e9rios desafios f\u00edsicos para os dispositivos endovenosos convencionais. Quando um operador tenta fazer avan\u00e7ar um guia de onda de fibra r\u00edgido e de grande di\u00e2metro atrav\u00e9s destas angula\u00e7\u00f5es acentuadas, a ponta distal colide inevitavelmente com as curvas estruturais da parede interna do vaso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este atrito mec\u00e2nico faz com que a fibra fique frequentemente presa nas v\u00e1lvulas venosas, em membranas intraluminais localizadas ou em estenoses fibr\u00f3ticas cr\u00f3nicas resultantes de tromboflebites superficiais anteriores. For\u00e7ar uma fibra r\u00edgida a passar por estas \u00e1reas acarreta o risco de perfura\u00e7\u00e3o mec\u00e2nica das camadas da t\u00fanica, antes mesmo de a energia do laser ser ativada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Al\u00e9m disso, quando se aplica energia num segmento altamente curvado, a ponta r\u00edgida da fibra tende a pressionar diretamente contra um dos lados da parede da veia, em vez de se manter centrada no l\u00famen. Este alinhamento descentrado provoca uma distribui\u00e7\u00e3o t\u00e9rmica desigual, em que a parede em contacto com a ponta da fibra recebe uma dose t\u00e9rmica excessiva e destrutiva, enquanto a parede oposta fica subtratada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do ponto de vista cl\u00ednico, este desequil\u00edbrio conduz \u00e0 ruptura focal da parede venosa, \u00e0 forma\u00e7\u00e3o imediata de um hematoma localizado, a hematomas p\u00f3s-operat\u00f3rios intensos e a uma elevada probabilidade de fecho incompleto, o que acaba por causar uma recanaliza\u00e7\u00e3o segmentar a longo prazo.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Erro da fibra r\u00edgida (risco de perfura\u00e7\u00e3o):\n===================\\\\======  &lt;-- Parede da veia\n \\\\  * A ponta da fibra pressiona e queima um dos lados\n======================\\\\==\n\nSolu\u00e7\u00e3o com micro-n\u00facleo flex\u00edvel (centrado):\n===================\\`----`=  &lt;-- A parede da veia flexiona em seguran\u00e7a\n [ 360\u00b0 ] &lt;-- A energia radial centra-se automaticamente\n===================.----.=\n<\/code><\/pre>\n\n\n\n<h2 class=\"wp-block-heading\">Cin\u00e9tica t\u00e9rmica da coagula\u00e7\u00e3o endotelial direcionada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A preven\u00e7\u00e3o destas complica\u00e7\u00f5es mec\u00e2nicas e t\u00e9rmicas requer um equil\u00edbrio preciso entre o comprimento de onda da energia e o sistema de administra\u00e7\u00e3o estrutural. O comprimento de onda do laser de 980 nm opera dentro de uma banda espec\u00edfica de absor\u00e7\u00e3o no infravermelho pr\u00f3ximo, onde a sua energia atua tanto no sangue intravascular como nas mol\u00e9culas de \u00e1gua localizadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ap\u00f3s a ativa\u00e7\u00e3o, os fot\u00f5es de 980 nm interagem imediatamente com as mol\u00e9culas de hemoglobina oxigenada e desoxigenada presentes no volume residual de sangue. Esta r\u00e1pida absor\u00e7\u00e3o cria bolhas de vapor t\u00e9rmicas localizadas e eleva a temperatura intravascular at\u00e9 ao ponto de ebuli\u00e7\u00e3o em mil\u00e9simos de segundo.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>Coeficiente de absor\u00e7\u00e3o de energia luminosa\n |\n | [Absor\u00e7\u00e3o da hemoglobina] -&gt; Pico a 980 nm\n | ____\n | \/    \\\n | \/ \\ [Absor\u00e7\u00e3o da \u00e1gua] -&gt; Refer\u00eancia a 1470 nm\n | \/ \\ ____\n |_________\/__________\\__________\/____\\____\n 400 600 800 1000     1200   Comprimento de onda (nm)\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Para transformar esta ebuli\u00e7\u00e3o r\u00e1pida num efeito terap\u00eautico controlado que contraia a parede da veia sem causar carboniza\u00e7\u00e3o estrutural, o sistema deve utilizar um ciclo de trabalho de impulsos estruturado. Ao operar o laser num modo de pulso cont\u00ednuo com portas ou de pulsos repetidos com temporiza\u00e7\u00e3o precisa, o per\u00edodo de emiss\u00e3o de energia corresponde ao tempo de relaxamento t\u00e9rmico da camada endotelial interna.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esta liberta\u00e7\u00e3o controlada garante que o calor gerado desnature a matriz de colag\u00e9nio interna da t\u00fanica m\u00e9dia e da \u00edntima, provocando o colapso do vaso e a sua oclus\u00e3o limpa. Uma vez que a emiss\u00e3o de energia \u00e9 rigorosamente controlada, o perfil t\u00e9rmico permanece confinado ao compartimento da veia safena, evitando a transfer\u00eancia excessiva de calor para o nervo safeno adjacente e para os tecidos subcut\u00e2neos circundantes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Geometria avan\u00e7ada de fibra com microaberturas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O design f\u00edsico da ferramenta de inser\u00e7\u00e3o \u00e9 fundamental para alcan\u00e7ar este n\u00edvel de controlo em anatomias tortuosas. Os n\u00facleos de fibra de vidro padr\u00e3o com ponta nua de 600 \u00b5m ou mais s\u00e3o intrinsecamente r\u00edgidos devido \u00e0s suas dimens\u00f5es transversais mais espessas, o que resulta num grande raio de curvatura que dificulta o deslocamento suave em curvas apertadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A mudan\u00e7a para um n\u00facleo de fibra \u00f3tica m\u00e9dica especializado de 400 \u00b5m altera drasticamente o desempenho mec\u00e2nico do sistema de administra\u00e7\u00e3o. O di\u00e2metro reduzido do n\u00facleo aumenta a flexibilidade estrutural, diminuindo o raio m\u00ednimo de curvatura do conjunto de fibras. Esta flexibilidade permite que o guia de ondas contorne curvas anat\u00f3micas acentuadas sem exercer press\u00e3o mec\u00e2nica excessiva para o exterior sobre as delicadas paredes venosas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A utiliza\u00e7\u00e3o de um n\u00facleo com um di\u00e2metro menor, de 400 \u00b5m, tamb\u00e9m afeta as caracter\u00edsticas f\u00edsicas da sa\u00edda na face de emiss\u00e3o, concentrando o feixe de laser num ponto geom\u00e9trico mais estreito. Para evitar que esta elevada concentra\u00e7\u00e3o de energia provoque a carboniza\u00e7\u00e3o localizada do tecido, a ponta da fibra apresenta um design de emiss\u00e3o radial microengenheirado. Este design projeta a energia de 980 nm para o exterior num padr\u00e3o cont\u00ednuo em anel de 360 graus, em vez de um feixe direto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O perfil de emiss\u00e3o radial centra automaticamente a ponta da fibra no interior do l\u00famen venoso atrav\u00e9s de for\u00e7as fluidodin\u00e2micas durante o processo de retra\u00e7\u00e3o. Consequentemente, mesmo ao percorrer curvas acentuadas, a energia do laser \u00e9 distribu\u00edda uniformemente por toda a circunfer\u00eancia interna da parede venosa, garantindo uma selagem t\u00e9rmica uniforme a pot\u00eancias operacionais mais baixas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Par\u00e2metros quantitativos de desempenho cl\u00ednico<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O conjunto de dados que se segue apresenta os par\u00e2metros operacionais e os resultados cl\u00ednicos de doentes tratados por doen\u00e7a venosa altamente tortuosa, utilizando uma fibra micro-radial de 400 \u00b5m e uma plataforma de laser de 980 nm.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Perfil do doente e patologia inicial<\/strong><\/td><td><strong>Segmento-alvo e tortuosidade-alvo<\/strong><\/td><td><strong>Configura\u00e7\u00e3o do n\u00facleo e da ponta da fibra<\/strong><\/td><td><strong>Comprimento de onda selecionado e sa\u00edda da consola<\/strong><\/td><td><strong>Densidade de energia linear (LEED)<\/strong><\/td><td><strong>An\u00e1lise cl\u00ednica e ecogr\u00e1fica de 30 dias<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Homem, 59 anos, classe C4a da CEAP, hiperpigmenta\u00e7\u00e3o grave na parte medial do tornozelo<\/td><td>GSV esquerda, segmento abaixo do joelho com 3 curvas acentuadas, 28 cm<\/td><td>N\u00facleo de 400 \u00b5m, anel radial fino 360<\/td><td>Monoterapia a 980 nm, 9 W cont\u00ednuos<\/td><td>60 joules por cm, recuo manual cont\u00ednuo<\/td><td>Oclus\u00e3o total, aus\u00eancia de equimose, sensibilidade nervosa intacta, veia com fibrose at\u00e9 3,1 mm<\/td><\/tr><tr><td>Mulher, 45 anos, classe C3 da CEAP, edema acentuado com veias acess\u00f3rias tortuosas<\/td><td>Ramo acess\u00f3rio anterior direito <a href=\"https:\/\/fotonmedix.com\/pt\/optimal-evlt-energy-density-controls-great-saphenous-vein-recanalization.html\/\"  data-wpil-monitor-id=\"4897\">Veia safena<\/a>, 32 cm<\/td><td>N\u00facleo de 400 \u00b5m, tampa radial de s\u00edlica fundida<\/td><td>Monoterapia a 980 nm, 8 W pulsada (D\/C 60%)<\/td><td>52 joules por cm, recuo autom\u00e1tico<\/td><td>100%: Fecho ao longo de todo o segmento, aus\u00eancia de perfura\u00e7\u00e3o da parede, pontua\u00e7\u00e3o m\u00ednima de dor p\u00f3s-operat\u00f3ria<\/td><\/tr><tr><td>Homem, 67 anos, classe C5 da CEAP, incha\u00e7o recorrente com borda da \u00falcera cicatrizada<\/td><td>GSV direito, la\u00e7o sinuoso da parte m\u00e9dia da coxa at\u00e9 \u00e0 parte superior da panturrilha, 41 cm<\/td><td>N\u00facleo de 400 \u00b5m, anel radial fino 360<\/td><td>Monoterapia a 980 nm, 10 W em modo cont\u00ednuo com modula\u00e7\u00e3o de porta (CW)<\/td><td>65 joules por cm, recuo cont\u00ednuo manual<\/td><td>Fecho total na jun\u00e7\u00e3o safeno-femoral, aus\u00eancia de extens\u00e3o \u00e0s veias profundas, doente totalmente m\u00f3vel no primeiro dia<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Este acompanhamento demonstra que a utiliza\u00e7\u00e3o de um canal de administra\u00e7\u00e3o de 400 \u00b5m permite aos operadores manter uma excelente efic\u00e1cia cl\u00ednica em vias vasculares complexas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A combina\u00e7\u00e3o de um n\u00facleo altamente flex\u00edvel com uma distribui\u00e7\u00e3o radial uniforme da energia garante uma desnatura\u00e7\u00e3o fi\u00e1vel dos tecidos, eliminando a necessidade de utilizar pot\u00eancias elevadas, que frequentemente causam perfura\u00e7\u00f5es dos vasos sangu\u00edneos e complica\u00e7\u00f5es p\u00f3s-operat\u00f3rias.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Normas de fabrico de guias de onda com n\u00facleo de vidro de alto desempenho<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A manuten\u00e7\u00e3o de um fornecimento consistente de energia atrav\u00e9s de um cabo de fibra \u00f3tica ativo requer o cumprimento rigoroso de protocolos avan\u00e7ados de fabrico de vidro. As fibras de qualidade m\u00e9dica, concebidas para transmitir sinais laser de alta energia, utilizam um n\u00facleo de s\u00edlica fundida sint\u00e9tica ultrapura, rodeado por um revestimento refletor especializado.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>+-------------------------------------------------------+\n|  N\u00facleo de s\u00edlica fundida sint\u00e9tica (com baixo teor de OH) | ---&gt; Transmite fot\u00f5es com pico elevado a 980 nm\n+-------------------------------------------------------+\n|  Revestimento de s\u00edlica fundida dopada com fl\u00faor | ---&gt; Impede a fuga \u00f3tica por reflex\u00e3o interna\n+-------------------------------------------------------+\n|  Revestimento protetor\/amortecedor exterior de poliimida | ---&gt; Proporciona elevada resist\u00eancia \u00e0 tra\u00e7\u00e3o e resist\u00eancia \u00e0 tor\u00e7\u00e3o\n+-------------------------------------------------------+\n<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Ao construir dispositivos otimizados para a transmiss\u00e3o a 980 nm, \u00e9 essencial controlar a concentra\u00e7\u00e3o interna de i\u00f5es hidroxilo (OH-) na matriz de s\u00edlica. Para comprimentos de onda puros no infravermelho pr\u00f3ximo, como os 980 nm, a utiliza\u00e7\u00e3o de uma formula\u00e7\u00e3o de s\u00edlica com baixo teor de OH garante a m\u00e1xima efici\u00eancia de transmiss\u00e3o e minimiza a absor\u00e7\u00e3o interna de luz. Esta matriz de vidro espec\u00edfica impede que o n\u00facleo da fibra aque\u00e7a durante a utiliza\u00e7\u00e3o prolongada, mantendo uma pot\u00eancia de sa\u00edda est\u00e1vel na ponta distal ao longo de todo o procedimento de abla\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A camada protetora exterior tamb\u00e9m desempenha um papel fundamental na durabilidade da fibra. O revestimento do revestimento de s\u00edlica dopada com fl\u00faor com uma camada resistente de poliimida proporciona a elevada resist\u00eancia \u00e0 tra\u00e7\u00e3o necess\u00e1ria para resistir a tor\u00e7\u00f5es e microfraturas quando a fibra \u00e9 dobrada em curvas anat\u00f3micas apertadas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se uma fibra de baixa qualidade for dobrada para al\u00e9m dos seus limites mec\u00e2nicos sob tens\u00e3o, a luz escapa atrav\u00e9s do revestimento, o que provoca a fus\u00e3o imediata e localizada do revestimento exterior. A utiliza\u00e7\u00e3o de um n\u00facleo de alta qualidade com 400 \u00b5m e baixo teor de OH, protegido por uma camada tamp\u00e3o de poliimida de alta resist\u00eancia, garante que o sistema de administra\u00e7\u00e3o possa percorrer anatomias tortuosas com seguran\u00e7a, mantendo simultaneamente um desempenho \u00f3tico consistente.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Integra\u00e7\u00e3o da cadeia de abastecimento e das opera\u00e7\u00f5es t\u00e9cnicas<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Por que raz\u00e3o os gestores de compras B2B preferem uma fibra radial de 400 \u00b5m em vez dos sistemas mais antigos de 600 \u00b5m para redes cl\u00ednicas vasculares especializadas?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Os gestores de compras no setor B2B preferem o design radial de 400 \u00b5m, uma vez que este reduz o risco cl\u00ednico global e diminui os custos operacionais. As fibras de grande di\u00e2metro (600 \u00b5m) apresentam elevada rigidez, o que conduz a taxas mais elevadas de perfura\u00e7\u00f5es da parede venosa durante a cirurgia e a subsequentes reclama\u00e7\u00f5es por responsabilidade cl\u00ednica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A flexibilidade avan\u00e7ada do n\u00facleo de 400 \u00b5m minimiza estas falhas t\u00e9cnicas, reduzindo drasticamente as taxas de complica\u00e7\u00f5es nos doentes e diminuindo a necessidade de consultas de retifica\u00e7\u00e3o p\u00f3s-operat\u00f3rias dispendiosas. Para redes cl\u00ednicas de grande volume, a transi\u00e7\u00e3o para um invent\u00e1rio padronizado de 400 \u00b5m otimiza a previsibilidade da cadeia de abastecimento e garante resultados altamente fi\u00e1veis para os doentes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">De que forma o comprimento de onda de 980 nm previne os riscos de trombose venosa profunda (TVP) frequentemente associados a interven\u00e7\u00f5es endovenosas de alta energia?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Os riscos de TVP nas terapias endovenosas decorrem geralmente do calor excessivo que se propaga para cima, para o sistema venoso profundo, na jun\u00e7\u00e3o safeno-femoral (SFJ). O comprimento de onda de 980 nm atua de forma eficiente sobre a hemoglobina, criando uma zona altamente localizada de coagula\u00e7\u00e3o intraluminal que sela rapidamente o vaso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Quando combinada com uma fibra radial de 400 \u00b5m, esta distribui\u00e7\u00e3o direcionada da energia permite ao operador reduzir a pot\u00eancia de sa\u00edda no console, conseguindo simultaneamente o fecho completo. A limita\u00e7\u00e3o da energia total emitida evita o excesso de calor na veia femoral comum, protegendo as estruturas venosas profundas de danos acidentais causados pelo calor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Que normas de controlo de qualidade deve uma fibra de 400 \u00b5m cumprir para garantir um funcionamento seguro com um console de laser de 980 nm?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Para garantir um desempenho cl\u00ednico seguro e evitar danos no equipamento, as fibras m\u00e9dicas de terceiros t\u00eam de cumprir tr\u00eas rigorosos crit\u00e9rios t\u00e9cnicos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Verifica\u00e7\u00e3o da excentricidade e do alinhamento:<\/strong> O n\u00facleo interno de s\u00edlica de 400 \u00b5m deve estar perfeitamente centrado no interior da sua camada de revestimento exterior, para evitar uma distribui\u00e7\u00e3o irregular do feixe e garantir um perfil de lan\u00e7amento exato na porta de liga\u00e7\u00e3o do SMA-905.<\/li>\n\n\n\n<li><strong>Ensaios de resist\u00eancia \u00e0 tra\u00e7\u00e3o e \u00e0 flex\u00e3o:<\/strong> Cada lote de fibra deve ser submetido a rigorosos ensaios de resist\u00eancia, dobrando o cabo em raios apertados sob tens\u00e3o, para confirmar que o revestimento de poliimida impede a ocorr\u00eancia de microfraturas durante a utiliza\u00e7\u00e3o.<\/li>\n\n\n\n<li><strong>Verifica\u00e7\u00e3o da transmiss\u00e3o \u00f3tica:<\/strong> A fibra deve apresentar uma efici\u00eancia de transmiss\u00e3o interna superior a 95% no espectro de 980 nm, garantindo que a pot\u00eancia programada na consola corresponda \u00e0 pot\u00eancia de sa\u00edda fornecida na ponta de tratamento.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Navigating tortuous great saphenous vein segments during EVLT laser procedures requires a flexible 400um medical fiber optics delivery system paired with a 980nm wavelength to achieve uniform transmural ablation while preventing localized vein wall rupture. Mechanical Obstacles in Navigating Tortuous Venous Segments Vascular specialists frequently encounter extreme anatomical variations when treating advanced superficial venous reflux. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"slim_seo":{"title":"Tratamento da tortuosidade da veia safena na EVLT sem perfura\u00e7\u00e3o do vaso - FotonMedix","description":"A navega\u00e7\u00e3o por segmentos tortuosos da veia safena maior durante procedimentos a laser EVLT requer um sistema de transmiss\u00e3o de fibra \u00f3tica m\u00e9dica flex\u00edvel de 400 \u00b5m, combinado com um laser de 980 n"},"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"","_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[19],"tags":[],"class_list":["post-14845","post","type-post","status-publish","format-standard","hentry","category-industry-news"],"metadata":{"_edit_lock":["1781144514:1"],"_edit_last":["1"],"_aioseo_title":["EVLT Laser Techniques for Tortuous Varicose Veins"],"_aioseo_description":["Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation."],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_og_article_tags":["a:0:{}"],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"catce":["sidebar-widgets4"],"views":["341"],"wpil_links_inbound_internal_count":["1"],"wpil_links_inbound_internal_count_data":["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"],"wpil_links_outbound_internal_count":["1"],"wpil_links_outbound_internal_count_data":["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"],"wpil_links_outbound_external_count":["0"],"wpil_links_outbound_external_count_data":["eJxLtDKwqq4FAAZPAf4="],"wpil_sync_report3":["1"],"wpil_sync_report2_time":["2026-09-16T07:50:41+00:00"],"wpil_is_inbound_links_added":["1"]},"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"fengmaiadmin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"pt_PT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"FotonMedix |\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"EVLT Laser Techniques for Tortuous Varicose Veins\" \/>\n\t\t<meta property=\"og:description\" content=\"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-07-04T11:30:38+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-07-04T11:30:38+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"EVLT Laser Techniques for Tortuous Varicose Veins\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#blogposting\",\"name\":\"EVLT Laser Techniques for Tortuous Varicose Veins\",\"headline\":\"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation\",\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#person\"},\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#articleImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"},\"datePublished\":\"2026-07-04T19:30:38+08:00\",\"dateModified\":\"2026-07-04T19:30:38+08:00\",\"inLanguage\":\"pt-PT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#webpage\"},\"articleSection\":\"Industry News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/pt\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"name\":\"Industry News\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"position\":3,\"name\":\"Industry News\",\"item\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#listItem\",\"name\":\"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#listItem\",\"position\":4,\"name\":\"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/categoria\\\/noticias\\\/industry-news#listItem\",\"name\":\"Industry News\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin#author\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin\",\"name\":\"fengmaiadmin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g\",\"width\":96,\"height\":96,\"caption\":\"fengmaiadmin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#webpage\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html\",\"name\":\"EVLT Laser Techniques for Tortuous Varicose Veins\",\"description\":\"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation.\",\"inLanguage\":\"pt-PT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/author\\\/fengmaiadmin#author\"},\"datePublished\":\"2026-07-04T19:30:38+08:00\",\"dateModified\":\"2026-07-04T19:30:38+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#website\",\"url\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/\",\"name\":\"FotonMedix\",\"inLanguage\":\"pt-PT\",\"publisher\":{\"@id\":\"https:\\\/\\\/fotonmedix.com\\\/pt\\\/#person\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"T\u00e9cnicas a laser EVLT para varizes tortuosas","description":"A navega\u00e7\u00e3o por veias sinuosas com um comprimento de onda de 980 nm e uma fibra \u00f3tica m\u00e9dica de 400 \u00b5m garante o fecho endotelial completo, evitando simultaneamente a perfura\u00e7\u00e3o da parede vascular.","canonical_url":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#blogposting","name":"EVLT Laser Techniques for Tortuous Varicose Veins","headline":"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation","author":{"@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin#author"},"publisher":{"@id":"https:\/\/fotonmedix.com\/pt\/#person"},"image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#articleImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"},"datePublished":"2026-07-04T19:30:38+08:00","dateModified":"2026-07-04T19:30:38+08:00","inLanguage":"pt-PT","mainEntityOfPage":{"@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#webpage"},"isPartOf":{"@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#webpage"},"articleSection":"Industry News"},{"@type":"BreadcrumbList","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt#listItem","position":1,"name":"Home","item":"https:\/\/fotonmedix.com\/pt","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias#listItem","position":2,"name":"News","item":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news#listItem","name":"Industry News"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news#listItem","position":3,"name":"Industry News","item":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news","nextItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#listItem","name":"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#listItem","position":4,"name":"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation","previousItem":{"@type":"ListItem","@id":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news#listItem","name":"Industry News"}}]},{"@type":"Person","@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin#author","url":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin","name":"fengmaiadmin","image":{"@type":"ImageObject","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/251e3799fc0e3aa28192a4ec864ea6d0715aeaa153f1a97df75ebe456ebdc0e4?s=96&d=wavatar&r=g","width":96,"height":96,"caption":"fengmaiadmin"}},{"@type":"WebPage","@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#webpage","url":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html","name":"EVLT Laser Techniques for Tortuous Varicose Veins","description":"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation.","inLanguage":"pt-PT","isPartOf":{"@id":"https:\/\/fotonmedix.com\/pt\/#website"},"breadcrumb":{"@id":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html#breadcrumblist"},"author":{"@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin#author"},"creator":{"@id":"https:\/\/fotonmedix.com\/pt\/author\/fengmaiadmin#author"},"datePublished":"2026-07-04T19:30:38+08:00","dateModified":"2026-07-04T19:30:38+08:00"},{"@type":"WebSite","@id":"https:\/\/fotonmedix.com\/pt\/#website","url":"https:\/\/fotonmedix.com\/pt\/","name":"FotonMedix","inLanguage":"pt-PT","publisher":{"@id":"https:\/\/fotonmedix.com\/pt\/#person"}}]},"og:locale":"pt_PT","og:site_name":"FotonMedix |","og:type":"article","og:title":"EVLT Laser Techniques for Tortuous Varicose Veins","og:description":"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation.","og:url":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html","article:published_time":"2026-07-04T11:30:38+00:00","article:modified_time":"2026-07-04T11:30:38+00:00","twitter:card":"summary_large_image","twitter:title":"EVLT Laser Techniques for Tortuous Varicose Veins","twitter:description":"Navigating tortuous veins with a 980nm wavelength and 400um medical fiber optics ensures complete endothelial closure while preventing vessel wall perforation."},"aioseo_meta_data":{"post_id":"14845","title":"T\u00e9cnicas a laser EVLT para varizes tortuosas","description":"A navega\u00e7\u00e3o por veias sinuosas com um comprimento de onda de 980 nm e uma fibra \u00f3tica m\u00e9dica de 400 \u00b5m garante o fecho endotelial completo, evitando simultaneamente a perfura\u00e7\u00e3o da parede vascular.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-07-04 11:54:59","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-06-11 02:21:07","updated":"2026-07-04 11:54:59","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/pt\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\" title=\"News\">News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news\" title=\"Industry News\">Industry News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tManaging Saphenous Vein Tortuosity in EVLT Without Vessel Perforation\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fotonmedix.com\/pt"},{"label":"News","link":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias"},{"label":"Industry News","link":"https:\/\/fotonmedix.com\/pt\/categoria\/noticias\/industry-news"},{"label":"Managing Saphenous Vein Tortuosity in EVLT Without Vessel Perforation","link":"https:\/\/fotonmedix.com\/pt\/managing-saphenous-vein-tortuosity-in-evlt-without-vessel-perforation.html"}],"medium_url":false,"thumbnail_url":false,"full_url":false,"_links":{"self":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts\/14845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/comments?post=14845"}],"version-history":[{"count":3,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts\/14845\/revisions"}],"predecessor-version":[{"id":18745,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/posts\/14845\/revisions\/18745"}],"wp:attachment":[{"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/media?parent=14845"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/categories?post=14845"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fotonmedix.com\/pt\/wp-json\/wp\/v2\/tags?post=14845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}